background image

2

INSTALLATION REQUIREMENTS

Tools and Parts

Gather the required tools and parts before starting installation. 

Read and follow the instructions provided with any tools listed here.

Tools Needed

 

Tape measure

 

Level

 

Phillips screwdriver

 

Flat-blade screwdriver

 

Wrench or pliers

 

 

3

/

8

" nut driver

 

Hand or electric drill

 

1

/

8

" (3.2 mm) drill bit

Parts supplied

Check that all parts are included.

 

3 - 10-32 hex nuts (attached to terminal block)

 

3 - Terminal lugs

 

Oven racks

 

2 - #12 x 1

5

/

8

" screws (for mounting anti-tip bracket)

 

Anti-tip bracket (taped inside upper oven with package 

containing literature)
Anti-tip bracket must be securely mounted to back wall or 

floor. Thickness of floor may require longer screws to anchor 

bracket to subfloor. Longer screws are available from your 

local hardware store.

Parts needed

If using a power supply cord:

 

A UL Listed power supply cord kit marked for use with 

ranges. The cord should be rated at 250 volts minimum, 

40 amps or 50 amps that is marked for use with nominal 

1

3

/

8

" (3.5 cm) diameter connection opening and must end  

in ring terminals or open-end spade terminals with  

upturned ends.

 

A UL Listed strain relief.

Check local codes. Check existing electrical supply. See the 

“Electrical Requirements” section.
It is recommended that all electrical connections be made by a 

licensed, qualified electrical installer.

Location Requirements

IMPORTANT: 

Observe all governing codes and ordinances.

 

It is the installer’s responsibility to comply with installation 

clearances specified on the model/serial/rating plate. The 

model/serial/rating plate is located behind the control panel.

 

To eliminate the risk of burns or fire by reaching over heated 

surface units, cabinet storage space located above the 

surface units should be avoided. If cabinet storage is to be 

provided, the risk can be reduced by installing a range hood 

that projects horizontally a minimum of 5" (12.7 cm) beyond 

the bottom of the cabinets.

 

Cabinet opening dimensions that are shown must be used. 

Given dimensions are minimum clearances.

 

The floor anti-tip bracket must be installed. To install the 

antitip bracket shipped with the range, see the “Install Anti-

Tip Bracket” section.

 

Grounded electrical supply is required. See the “Electrical 

Requirements” section.

IMPORTANT:

 To avoid damage to your cabinets, check with 

your builder or cabinet supplier to make sure that the materials 

used will not discolor, delaminate or sustain other damage. This 

range has been designed in accordance with the requirements 

of UL and CSA International and complies with the maximum 

allowable wood cabinet temperatures of 194°F (90°C).

Mobile Home - Additional Installation Requirements

The installation of this range must conform to the Manufactured 

Home Construction and Safety Standard, Title 24 CFR, 

Part 3280 (formerly the Federal Standard for Mobile Home 

Construction and Safety, Title 24, HUD Part 280). When such 

standard is not applicable, the Standard for Manufactured Home 

Installations, ANSI A225.1/NFPA 501A or with local codes.

Mobile home installations require:

 

When this range is installed in a mobile home, it must be 

secured to the floor during transit. Any method of securing 

the range is adequate as long as it conforms to the 

standards listed above.

 

Four-wire power supply cord or cable must be used in a 

mobile home installation. The appliance wiring will need to 

be revised. See the “Electrical Connection” section.

Tip Over Hazard

A child or adult can tip the range and be killed.
Install anti-tip bracket to floor or wall per installation instructions.
Slide range back so rear range foot is engaged in the slot of the anti-tip bracket.
Re-engage anti-tip bracket if range is moved.
Do not operate range without anti-tip bracket installed and engaged.
Failure to follow these instructions can result in death or serious burns to children and adults.

To verify the anti-tip bracket is installed and engaged:

Slide range forward.

Look for the anti-tip bracket securely attached to floor or wall.

Slide range back so rear range foot is under anti-tip bracket.

See installation instructions for details.

WARNING

Anti-Tip

Bracket

Range Foot

Содержание KFED500EWH03

Страница 1: ...ement est bien installée et engagée 18 Réglage de l aplomb de la cuisinière 19 Achever l installation 20 Déplacement de la cuisinière 20 Table of Contents Table des matières W10694065B IMPORTANT Save for local electrical inspector s use IMPORTANT À conserver pour consultation par l inspecteur local des installations électriques RANGE SAFETY You can be killed or seriously injured if you don t immed...

Страница 2: ...at are shown must be used Given dimensions are minimum clearances The floor anti tip bracket must be installed To install the antitip bracket shipped with the range see the Install Anti Tip Bracket section Grounded electrical supply is required See the Electrical Requirements section IMPORTANT To avoid damage to your cabinets check with your builder or cabinet supplier to make sure that the materi...

Страница 3: ...imum when bottom of wood or metal cabinet is covered by not less than 1 4 0 64 cm flame retardant millboard covered with not less than No 28 MSG sheet steel 0 015 0 4 mm stainless steel 0 024 0 6 mm aluminum or 0 020 0 5 mm copper 30 76 2 cm minimum clearance between the top of the cooking platform and the bottom of an uncovered wood or metal cabinet A 353 4 1 8 90 8 cm 0 3 cm cooktop height minim...

Страница 4: ...aluminum cable See the Electrical Connection U S A Only section Allow 2 to 3 ft 61 0 cm to 91 4 cm of slack in the line so that the range can be moved if servicing is ever necessary A UL Listed conduit connector must be provided at each end of the power supply cable at the range and at the junction box Wire sizes and connections must conform with the rating of the range The wiring diagram is locat...

Страница 5: ...nder range 2 Remove oven racks and parts package from inside oven 3 To place range on its back take 4 cardboard corners from the carton Stack one cardboard corner on top of another Repeat with the other 2 corners Place them lengthwise on the floor behind the range to support the range when it is laid on its back 4 Using 2 or more people firmly grasp the range and gently lay it on its back on the c...

Страница 6: ...ket holes of the determined mounting method See the following illustrations 5 Using a Phillips screwdriver mount anti tip bracket to the wall or floor with the two 12 x 15 8 screws provided WARNING Tip Over Hazard A child or adult can tip the range and be killed Install anti tip bracket to floor or wall per installation instructions Slide range back so rear range foot is engaged in the slot of the...

Страница 7: ...cord through the strain relief in the cord conduit plate on bottom of range Allow enough slack to easily attach the wiring to the terminal block Tighten strain relief screw against the power supply cord WARNING Electrical Shock Hazard Disconnect power before servicing Use a new 40 amp power supply cord Plug into a grounded outlet Failure to follow these instructions can result in death fire or ele...

Страница 8: ...nstallation following instructions for your type of electrical connection 4 wire recommended 3 wire if 4 wire is not available Electrical Connection Options If your home has And you will be connecting to Go to Section 4 wire receptacle NEMA type 14 50R A UL Listed 250 volt minimum 40 amp range power supply cord 4 wire connection Power Supply Cord 4 wire direct A fused disconnect or circuit breaker...

Страница 9: ...lock posts with 10 32 hex nuts 7 Securely tighten hex nuts NOTE For power supply cord replacement only use a power cord rated at 250 volts minimum 40 amps or 50 amps that is marked for use with nominal 13 8 3 5 cm diameter connection opening with ring terminals and marked for use with ranges 8 Replace terminal block access cover 9 Slide range back so rear range foot is under the anti tip bracket S...

Страница 10: ...p the insulation back 1 2 5 cm from the end of each wire 2 Allow enough slack in the wire to easily attach the wiring terminal block 3 Complete electrical connection according to your type of electrical supply 4 wire or 3 wire connection 4 wire Connection Direct Wire Use this method for New branch circuit installations 1996 NEC Mobile homes Recreational vehicles In an area where local codes prohib...

Страница 11: ... range back so rear range foot is under the anti tip bracket See the Verify Anti Tip Bracket is Installed and Engaged section 3 wire connection Direct Wire Use this method only if local codes permit connecting ground conductor to neutral supply wire 1 Pull the conduit through the hole and conduit plate on bottom of range Allow enough slack to easily attach the wiring to the terminal block 2 Attach...

Страница 12: ...the bracket Verify that the bracket is held securely in place by the mounting screws 4 Slide the range forward and verify that the anti tip bracket is securely attached to the floor or wall 5 Slide range back so the rear range foot is inserted into the slot of the anti tip bracket IMPORTANT If the back of the range is more than 2 5 1 cm from the mounting wall the rear range foot may not engage the...

Страница 13: ... slide range onto cardboard or hardboard to avoid damaging the floor covering If removing the range is necessary for cleaning or maintenance For power supply cord connected ranges 1 Slide range forward 2 Unplug the power supply cord 3 Complete cleaning or maintenance 4 Plug power supply cord into a grounded outlet 5 Slide range back so rear range foot is under anti tip bracket 6 Refer to the Verif...