KitchenAid KFED500EWH03 Скачать руководство пользователя страница 13

13

Complete Installation

1. 

Check that all parts are now installed. If there is an extra 

part, go back through the steps to see which step was 

skipped.

2. 

Check that you have all of your tools.

3. 

Dispose of/recycle all packaging materials.

4. 

Check that the range is level. See the “Level Range” section.

5. 

Use a mild solution of liquid household cleaner and warm 

water to remove waxy residue caused by shipping material. 

Dry thoroughly with a soft cloth. For more information, read 

the “Range Care” section of the Use and Care Guide.

6. 

Read the range Use and Care Guide.

7. 

Plug power cord into appropriate outlet. Slide range into its 

final location. Check that the flexible conduit or power supply 

cord are not bent.

8. 

Turn power on. Turn on surface elements and oven. See 

the Use and Care Guide for specific instruction on range 

operation.

If range does not operate, check the following:

 

Household fuse is intact and tight; or circuit breaker has not 

tripped.

 

Range is plugged into a grounded outlet.

 

Electrical supply is connected.

 

See the “Troubleshooting” section in the Use and Care 

Guide.

When the range has been on for 5 minutes, check for heat. 

If range is cold, turn off the range and contact a qualified 

technician.

Moving the Range

When moving range, slide range onto cardboard or hardboard to 

avoid damaging the floor covering.

If removing the range is necessary for cleaning or maintenance:

For power supply cord-connected ranges:
1. 

Slide range forward.

2. 

Unplug the power supply cord.

3. 

Complete cleaning or maintenance.

4. 

Plug power supply cord into a grounded outlet.

5. 

Slide range back so rear range foot is under anti-tip bracket.

6. 

Refer to the “Verify Anti-Tip Bracket Is Installed and 

Engaged” section to verify engagement.

7. 

Check that range is level.

For direct-wired ranges:

1. 

Disconnect power.

2. 

Slide range forward.

3. 

Complete cleaning or maintenance.

4. 

Slide range back so rear range foot is under anti-tip bracket.

5. 

Refer to the “Verify Anti-Tip Bracket Is Installed and 

Engaged” section to verify engagement.

6. 

Check that range is level.

7. 

Reconnect power.

WARNING

Tip Over Hazard

A child or adult can tip the range and be killed.
Install anti-tip bracket to floor or wall per installation 

instructions.
Slide range back so rear range foot is engaged in the 

slot of the anti-tip bracket.
Re-engage anti-tip bracket if range is moved.
Do not operate range without anti-tip bracket installed 

and engaged.
Failure to follow these instructions can result in death 

or serious burns to children and adults.

WARNING

Electrical Shock Hazard

Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.

W10694065B

8/16

Содержание KFED500EWH03

Страница 1: ...ement est bien installée et engagée 18 Réglage de l aplomb de la cuisinière 19 Achever l installation 20 Déplacement de la cuisinière 20 Table of Contents Table des matières W10694065B IMPORTANT Save for local electrical inspector s use IMPORTANT À conserver pour consultation par l inspecteur local des installations électriques RANGE SAFETY You can be killed or seriously injured if you don t immed...

Страница 2: ...at are shown must be used Given dimensions are minimum clearances The floor anti tip bracket must be installed To install the antitip bracket shipped with the range see the Install Anti Tip Bracket section Grounded electrical supply is required See the Electrical Requirements section IMPORTANT To avoid damage to your cabinets check with your builder or cabinet supplier to make sure that the materi...

Страница 3: ...imum when bottom of wood or metal cabinet is covered by not less than 1 4 0 64 cm flame retardant millboard covered with not less than No 28 MSG sheet steel 0 015 0 4 mm stainless steel 0 024 0 6 mm aluminum or 0 020 0 5 mm copper 30 76 2 cm minimum clearance between the top of the cooking platform and the bottom of an uncovered wood or metal cabinet A 353 4 1 8 90 8 cm 0 3 cm cooktop height minim...

Страница 4: ...aluminum cable See the Electrical Connection U S A Only section Allow 2 to 3 ft 61 0 cm to 91 4 cm of slack in the line so that the range can be moved if servicing is ever necessary A UL Listed conduit connector must be provided at each end of the power supply cable at the range and at the junction box Wire sizes and connections must conform with the rating of the range The wiring diagram is locat...

Страница 5: ...nder range 2 Remove oven racks and parts package from inside oven 3 To place range on its back take 4 cardboard corners from the carton Stack one cardboard corner on top of another Repeat with the other 2 corners Place them lengthwise on the floor behind the range to support the range when it is laid on its back 4 Using 2 or more people firmly grasp the range and gently lay it on its back on the c...

Страница 6: ...ket holes of the determined mounting method See the following illustrations 5 Using a Phillips screwdriver mount anti tip bracket to the wall or floor with the two 12 x 15 8 screws provided WARNING Tip Over Hazard A child or adult can tip the range and be killed Install anti tip bracket to floor or wall per installation instructions Slide range back so rear range foot is engaged in the slot of the...

Страница 7: ...cord through the strain relief in the cord conduit plate on bottom of range Allow enough slack to easily attach the wiring to the terminal block Tighten strain relief screw against the power supply cord WARNING Electrical Shock Hazard Disconnect power before servicing Use a new 40 amp power supply cord Plug into a grounded outlet Failure to follow these instructions can result in death fire or ele...

Страница 8: ...nstallation following instructions for your type of electrical connection 4 wire recommended 3 wire if 4 wire is not available Electrical Connection Options If your home has And you will be connecting to Go to Section 4 wire receptacle NEMA type 14 50R A UL Listed 250 volt minimum 40 amp range power supply cord 4 wire connection Power Supply Cord 4 wire direct A fused disconnect or circuit breaker...

Страница 9: ...lock posts with 10 32 hex nuts 7 Securely tighten hex nuts NOTE For power supply cord replacement only use a power cord rated at 250 volts minimum 40 amps or 50 amps that is marked for use with nominal 13 8 3 5 cm diameter connection opening with ring terminals and marked for use with ranges 8 Replace terminal block access cover 9 Slide range back so rear range foot is under the anti tip bracket S...

Страница 10: ...p the insulation back 1 2 5 cm from the end of each wire 2 Allow enough slack in the wire to easily attach the wiring terminal block 3 Complete electrical connection according to your type of electrical supply 4 wire or 3 wire connection 4 wire Connection Direct Wire Use this method for New branch circuit installations 1996 NEC Mobile homes Recreational vehicles In an area where local codes prohib...

Страница 11: ... range back so rear range foot is under the anti tip bracket See the Verify Anti Tip Bracket is Installed and Engaged section 3 wire connection Direct Wire Use this method only if local codes permit connecting ground conductor to neutral supply wire 1 Pull the conduit through the hole and conduit plate on bottom of range Allow enough slack to easily attach the wiring to the terminal block 2 Attach...

Страница 12: ...the bracket Verify that the bracket is held securely in place by the mounting screws 4 Slide the range forward and verify that the anti tip bracket is securely attached to the floor or wall 5 Slide range back so the rear range foot is inserted into the slot of the anti tip bracket IMPORTANT If the back of the range is more than 2 5 1 cm from the mounting wall the rear range foot may not engage the...

Страница 13: ... slide range onto cardboard or hardboard to avoid damaging the floor covering If removing the range is necessary for cleaning or maintenance For power supply cord connected ranges 1 Slide range forward 2 Unplug the power supply cord 3 Complete cleaning or maintenance 4 Plug power supply cord into a grounded outlet 5 Slide range back so rear range foot is under anti tip bracket 6 Refer to the Verif...

Отзывы: