background image

4

Control Pinout

Meter Check of Loads and Fuses  

Dishwasher Strip Circuits

The following individual circuits are for use in diagnoses. Do not continue with 

the diagnosis of the appliance if a fuse is blown, a circuit breaker is tripped, or if 

there is less than a 120-volt power supply at the wall outlet.

Unplug dishwasher or disconnect power.

Perform resistance checks. To check resistance of a component, 

disconnect harness leads first.

Door Switch

Wash/Rinse

Water Heating/Heat Dry and Water Sensing with O.W.I. Sensor (Water/Air/Soil/Temperature)

Pump is washing and control monitors temperature during water heating periods. See “Wash/Rinse” and “Water Sensing with O.W.I. Sensor (Water/Air/Soil/

Temperature)” circuits.  

Fill

(Top)

W2

P5

P6

P7

P8

P9

P10

P11

P12

P13

-4 -3 -2 -1 -2 -1

-1

-6

-9 -1

-6 -1

-6 -1

-5-6 -1 -3 -5 -1 -2 -4 -6 -1 -3

(OWI)

P12 (Wide Out)

P13

P4

P5

P6

BR

P7

BU

P8

RD

P9

V

P10

BR

P11

RD

P12

YL

 of F9 Triac Fuse

 of F8 Motor Fuse

Electronic Control

Electronic Control

Micro Pin

Micro Pin

Micro Pin

Micro Pin

          K4

Motor (N) Relay

           K3

Heater (L1) Relay

         K2

Pilot (L1) Relay

            K1

Heater (N) Relay

N.O.

N.O.

N.O.

N.O.

(To Wash Motor)

(To Heater)

     (To Wash Motor,

Vent, and Triac Loads)

(To Heater)

N.O.

  Door

 Switch

Sensing

  Input

Ref

P9-5

P10-4

  Door

 Switch

P9-6

13V

V

V

Motor Power

  Sense

 Resistor

or Jumper

     0

 

L1

BK

P4-2

P5-2

P5-1

P4-1

N

WH

          K4

 Motor N Relay

(Also see Door

 Switch Circuit)

 N.O.

   1-PH Sync

Wash Motor

(Power Supply)

Electronic Control

Electronic Control

Pin 3

Pin 2

  120V, 60 Hz

  5-15

Ω

, 60W 

Fuse

  F8

          K2

 Pilot L1 Relay

(Also see Door

 Switch Circuit)

   Use holes of jumper

W2 as test points for F8.

(Top Hole)

(Bottom

   Hole)

 N.O.

W2

(LB)

TURQ

TURQ

(LB)

L1

BK

Electronic Control

N.O.

         K3

Heater L1 Relay

 (Also see Door 

 Switch Circuit) 

   Hi-Limit

 Thermostat

     Opens 

 207°F - 217°F

(97°C - 103°C)

 Heater Element

     8

Ω

 - 30

Ω

 

   120V, 60 Hz

    Plastic Models: 

805W Wet / 385W Dry

Stainless Steel Models: 

785W / 500W Dry

N.C.

P4-2

P4-3 BU/RD

BU/RD

BU/WHP4-4

P4-1 WH

N

Electronic Control

N.O.

         K1

Heater N Relay

 (Also see Door 

 Switch Circuit) 

Electronic

 Control

P12-6

P12-5
P12-4

P12-3

P12-2
P12-1

YL
YL
YL
YL
YL

YL

Pin 1
Pin 2

Pin 3

Pin 4
Pin 5

Pin 6

  Measure NTC resistance at P12-1 and 

P12-3 connector disconnected from control.

Turbidity Drive

Foam Drive
OPT Sig

VCC

Ref

NTC

O.W.I. Sensor

Temperature: NTC Thermistor 

46K

Ω

 - 52K

Ω

 at 77°F (25°C)

11K

Ω

 - 13K

Ω

 at 140°F (60°C)

Heater

L1

BK

P4-2

P6-4

P10-1

P6-6

P6-7

P6-9

P4-1

Use top hole of jumper

W2 as test point for F9.

N.O.

        K2

 Pilot L1 Relay

(Also see Door

 Switch Circuit)

Fuse

  F9

Electronic Control

Electronic Control

          Float

 (In normal position,

holds switch closed.)

BR

BR N.O.

Pin 3 Pin 1

   Overfill 

Float Switch

No test pad on P6-4.

Recommend using test pad on P10-1.

No test pad on P6-7.

Recommend using test pad on P6-6.

Electronic Control

Float Switch

      Input

BR

BR

Pin 3

Pin 1

Triac

       Fill Valve

 890

 

- 1,600

 

120V, 60 Hz, 6W

WH

N

Содержание KDTE104ESS3

Страница 1: ...an result in death or electrical shock WARNING Electrical Shock Hazard Disconnect power before servicing Replace all parts and panels before operating Failure to do so can result in death or electrical shock SPECIFICATIONS Electrical Supply Under load 60 Hz 120 VAC Lower Spray Arm Rotation 12 to 40 rpm Supply Water Flow Rate To fill 2 qt 1 9 L in 27 seconds 120 psi maximum 20 psi minimum Upper Spr...

Страница 2: ...ive 13V VCC Wide Data 13V Beeper REF VCC Wide Data P1A P1B LED Displays 14 pin Mechanical Push Button Boards 20 pin Active Overlays 19 pin ZIF 1 3 2 4 5 6 7 Black Stripe On Connector Red Stripe On Connector P6 1 P6 3 P6 4 P6 6 P6 7 P6 9 P7 1 P7 3 P7 4 P7 6 P8 1 P8 3 P8 4 P8 6 P9 1 P9 3 P9 5 P9 6 P10 1 P10 3 P10 5 P10 4 Micro Pin Micro Pin Micro Pin K2 F8 Fuse Or 5 1 Dispenser Wax Motor P13 1 P13 2...

Страница 3: ... 0 01 HIT 7 Seg 7 Seg 7 Seg 7 Seg 7 Seg AC FAN MOTOR IF PRESENT 1 To invoke the Diagnostics cycle perform the following while in standby Press any 3 keys in the sequence 1 2 3 1 2 3 1 2 3 with no more than 1 second between key presses The Service Diagnostics Cycle will start when the door is closed To rapid advance 1 interval at a time press the Start Resume key Rapid advance may skip sensor check...

Страница 4: ...1 P4 1 N WH K4 Motor N Relay Also see Door Switch Circuit N O 1 PH Sync Wash Motor Power Supply Electronic Control Electronic Control Pin 3 Pin 2 120V 60 Hz 5 15Ω 60W Fuse F8 K2 Pilot L1 Relay Also see Door Switch Circuit Use holes of jumper W2 as test points for F8 Top Hole Bottom Hole N O W2 LB TURQ TURQ LB L1 BK Electronic Control N O K3 Heater L1 Relay Also see Door Switch Circuit Hi Limit The...

Страница 5: ...ch Circuit Fuse F9 Electronic Control No test pad on P7 4 Recommend using test pad on P10 1 Electronic Control Triac Diverter Motor 1 100Ω 1 400Ω 120V 60 Hz 3W L1 Regeneration Valve BK P4 2 P7 3 P10 1 P7 1 P4 1 N WH V V Use top hole of jumper W2 as test point for F9 K2 Pilot L1 Relay Also see Door Switch Circuit Fuse F9 Pin 1 Pin 3 N O Electronic Control Electronic Control Triac No test pad on P7 ...

Страница 6: ...n loads and checks sensors SERVICE CYCLE ERROR 1 INTERVAL 2 A tone will play when service error code 1 is displayed SHOW FUNCTION CODE PAUSE SHOW PROBLEM CODE PAUSE Repeat 3 times unless advanced by Start key Count Clean LED flashes 2 sec Count Clean LED flashes 5 sec OR ON DISPLAY MODELS Read F on Display 0 5 sec Read E on Display 1 sec SERVICE CYCLE ERROR 2 INTERVAL 1 SHOW FUNCTION CODE PAUSE SH...

Страница 7: ...un diagnostics after replacing new OWI to force calibration on next wash cycle Function Code Problem Code Causes What to Check 3 Thermistor OWI cont 3 Failed Calibration cont 2 Drain hose check valve not sealing Dirty water backs into dishwasher after draining 1 Disconnect drain hose at plumbing connection 2 Elevate hose above dishwasher and fill with water If water flows into dishwasher replace e...

Страница 8: ...or disconnect power and replace control Function Code Problem Code Causes What to Check 6 Inlet Water cont 4 Float Switch Open cont 4 Fill valve mechanically stuck open Confirm dishwasher fills while the door is open If yes unplug dishwasher or disconnect power turn off water to dishwasher replace fill valve and turn water back on 5 Too many suds 1 Allow unit to fill and wash for 1 minute Open doo...

Страница 9: ...er Drive circuit on the control Unplug dishwasher or disconnect power and replace control 3 Drying Fan Error 1 Loose connection in fan circuit and or open fan motor Unplug dishwasher or disconnect power and check resistances of fan motor and all connections in the fan circuit Fix replace open connections or fan 2 Fan drive circuit on the control Unplug dishwasher or disconnect power and replace co...

Страница 10: ... cause long cycles but will typically cause a water heating fault Refer to Service Error Codes table 7 1 Customer Description Potential Causes Check Related Error Code Long Cycles and or Stuck in Certain Part of Cycle cont 5 Heater takes a long time to heat water with low voltage Check for at least 100 VAC at power source 6 Incoming water under 84ºF 29ºC 1 Be sure dishwasher is connected to the ho...

Страница 11: ...rror Codes table 6 8 Customer Description Potential Causes Check Related Error Code Film or Spots on Glasses and or Dishes 1 Customer not using rinse aid and or heated dry Check rinse aid gauge level on dispenser Instruct customer how to fill and monitor add or use rinse aid 2 RInse aid dispenser problem Refer to Service Error Codes table 10 1 3 Hard water leaving film on dishes Check water hardne...

Страница 12: ...y Operation cont 5 Drains too long cont 3 Check for blockages from sump check valve to customer s plumbing Potential problems plugged garbage disposer or plug not knocked out drain loop check valve stuck and or plugged hoses 4 Remove drain pump and check impeller normally there is some uneven resistance If it is stripped replace drain pump 3 3 6 Loose connection in vent circuit and or open vent wa...

Отзывы: