Secure the hob to the underside of the workshop using the fixings provided. Screw one end of
the bracket into the pre-drilled holes in the underside of the hob. The other end of the bracket
should be located underneath the worktop to secure the hob in position.
1.3
Gas connection
The appliance´s gas inlet fitting the ½” male threaded conic gas type in accordance with the
ISO 7-1 standards. Make the connection using rigid pipe. When making the gas connection, it
is important to place the gasket (A) in between the inlet pipe (C) and the elbow (B), to ensure a
gas tight seal.
1.4
Electrical connection
This appliance must be connected by a competent person, using fixed wiring via double pole
switched fused spur outlet with a fuse rating of 3 amps and with a contact separation of at least
3 mm in all poles. We recommend that the appliance is connected by a qualified electrician
who will comply with I.E.E regulations. The wires in the mains lead are coloured in accordance
with the following code: Green & Yellow = Earth, Blue = Neutral, Brown = Live.
Содержание 5Z-KHSSW
Страница 11: ...Demontage...