Replace the injectors with the corresponding injector from the table on page below (see Fig.
6). First, remove the burner caps and rings with a socket spanner “B”, unscrew injector “A”
(see Fig. 6).
The adjustment of the reduced rate position is as follows (Fig. 7): Light the burner and turn
the knob to reduced rate position.
Remove the knob “M” which is simply inserted into, tap stem. Insert a small screwdriver “D”
into the top
shaft “C” and turn the bypass screw left or right until flame of the burner is
conveniently regulated to the low position.
Make sure that when turning quickly from “Full on” position to reduced rate position that the
burner does not extinguish.