MA0886RHG
30
9-2. Production and attachment of cylinder adapter
・
Attach with the surface run-out of the cylinder adapter and the run-out of the spigot
joint at 0.005 mm or less. (Fig. 10) Large run-out causes vibration and shortens the
life of the cylinder significantly.
○
Bring the cylinder as close to the lathe spindle support as possible. The attaching
method of the cylinder adapter and the measuring method of run-out are illustrated in
the drawings below. (Fig. 9, Table 9)
○
Never fail to provide a setscrew to prevent loosening of the cylinder adapter. (Fig. 10)
Cylinder adapter attaching part
Fig. 9
Run-out measurement of the cylinder adapter
Fig. 10