MA0886RHG
24
6-2. Adjusting the position of a proximity switch
Read following instruction when you adjust the proximity switch. (Fig.7)
①
Loosen the machine screw [31], then remove the cover [14].
②
Loosen the socket head cap screw [20] that fix the adjusting plate [15].
③
Unclamp the chuck.
④
Install one proximity switch on the outer surface of the casing [11], passing through the
adjusting plate [15], and make it approach to the detectable plate [16] until the LED of
proximity switch lights up. At this time, adjust the screw of proximity switch so that the
distance between proximity switch and outside diameter end of detectable plate [16] is
about 1 mm, and slide to adjust the adjusting plate [15] in the axial direction.
⑤
Tighten the socket head cap screw [20] to fix the adjusting plate [15].
⑥
Grip the workpiece.
⑦
For another proximity switch proceeds in the same way as it is described from point 4
and 5.
⑧
Confirm whether LED lights up by opening and closing the chuck several times.
⑨
Tighten the machine screw [31] to fix the cover [14].
Fig.7