© MMXIX Kirby Morgan Dive Systems, Inc. All rights reserved. Document # 190625006
SuperFlow® 350 Regulator & Exhaust System Post Dive Cleaning & Sanitizing
SuperFlow® 350 Regulator
Remove the regulator cover to inspect the diaphragm.
2) Remove the nose clearing device by loosening
the packing nut removing the knurled knob and
sliding the shaft out through the oral nasal.
3) Remove the microphone from the oral nasal
mask then remove the oral nasal mask from the
helmet.
4) Remove the oral nasal valve and body.
Remove the microphone so you can
remove the oral nasal mask.
5) Using a small Phillips screwdriver, carefully
remove the two clamps, screws & nuts then pull
the whiskers away from the water dump body.
The exhaust valve inserts are recessed on one side to accept the exhaust valves so they sit flush in the inserts.
The exhaust valves must be installed properly in the inserts or they will not seal or perform properly.
Correct
INCORRECT