
MKIII OPERATOR'S MANUAL
122
PMT.WINDOW.TIME
float seconds
Immediate
seconds in a window. Should be an integral
multiple of PMT resolution time.
RESET.TIME.OUT
unsigned integer
seconds
on reset
the length of time allowed for initialization of
all motors. This should be larger than the
largest value of MOTOR.TIME.OUT.
RH.ORIGIN
float volt at 0 RH
immediate
Humidity sensor calibration provided by
manufacturer
RH.SLOPE
Float volt/%
immediate
Humidity sensor calibration provided by
manufacturer
SUPPLY.CONVERSION
[<powerSupply>]
float
Immediate
Number of volts at the output of the supply to
read one volt via the A/D
SUPPLY.DELTA[
<powerSupply>]
float volts
on reset
Permitted (max-nominal and nominal-min)
voltage in watermark recording
SUPPLY.NOMINAL [
<powerSupply>]
float volts
on reset
Center voltage in watermark recording
TEMP.DELTA [ <thermalPoint>] float degrees
on reset
Permitted (max-nominal and nominal-min)
temperature excursion in watermark
recording
TEMP.NOMINAL [
<thermalPoint>]
float degrees
on reset
Center temperature in watermark recording
TEMP.ORIGIN [<thermalPoint>] float degrees
Immediate
number of degrees Celsius offset for 0 volts
at the A/D
TEMP.SLOPE [<thermalPoint>] Float degrees/volt
immediate
number of degrees Celsius per volt at the A/D
(linear thermistors are used here)
TRACKER.DEBOUNCE.TIME
Float seconds
immediate
debounce time for the tracker control
switches
USE.B3.FOR.LAMPS
Boolean
immediate
Sets response to command: B,3. If set to
YES, lamps are turned on else the command
is ignored.
VERSION.ELEC
unsigned byte
immediate
Records the electronics version
VOLTS.PER.BIT
Float volts
immediate
Resolution of A/D converter in volts per A/D
unit (bit)
Possible <index>es
<index>
Meaning
possibilities/format
<address>
location within the space
ANSI C integer format
1
<analogPt>
which A/D mux input
integer 0 to 23
<digitalPt>
which digital input
integer 0 to 15
<lamp>
which Brewer internal lamp
0 to 1 or identifier - One of: HG, STD
<motorId>
identifies a motor
see section on I command
<powerSupply>
identifies a power supply
0 to 6 or identifier One of:
HV, +12V, +5V, -12V, +24V, +5VSEC (secondary
supply), -5VSEC
<thermalPoint>
identifies a thermal sensor
0 to 5 or identifier One of:
PMT (photomultiplier), FAN (internal temperature),
BASE, BELOW.SPECTRO,
WINDOW.AREA, EXTERNAL (external temperature)
<trackerSwitch>
identifies a tracker switch
digital input
0 to 4 or identifier One of:
CW, CCW, UP, DOWN, COARSE
Examples
?MOTOR.MAX.ACC[IRIS]
reports the current maximum acceleration for the iris motor.
!PMT.HV.TOLERANCE 50
sets the value of the high voltage tolerance to 50 millivolts.
1
The first character must be a digit. The number interpreted as decimal unless the first digit is a 0 in which
case the second character is tested. If it is 'x' or 'X' the remaining digits are interpreted as a hexadecimal
number. If the second character is a digit the number is interpreted as octal.
Содержание Brewer Mk III
Страница 1: ...Operators manual Spectrophotometer Brewer MkIII...
Страница 3: ...ii...
Страница 5: ...2...
Страница 7: ...4...
Страница 25: ...MKIII OPERATOR S MANUAL 22...
Страница 27: ...MKIII OPERATOR S MANUAL 24 Figure 3 2 Brewer Equipment Setup Figure 3 3 Brewer Spectrophotometer Tracker Tripod...
Страница 29: ...MKIII OPERATOR S MANUAL 26 Figure 3 4 Brewer Spectrophotometer Tripod...
Страница 63: ...MKIII OPERATOR S MANUAL 60...
Страница 83: ...MKIII OPERATOR S MANUAL 80...
Страница 91: ...MKIII OPERATOR S MANUAL 88...
Страница 93: ...MKIII OPERATOR S MANUAL 90...
Страница 97: ...MKIII OPERATOR S MANUAL 94...
Страница 129: ...MKIII OPERATOR S MANUAL 126...
Страница 135: ...MKIII OPERATOR S MANUAL 132...