background image

Earth Mark

Ground Terminal

Output Indicator Light (Green)

Overload Indicator Light (Red)

AC Receptacle

In Case of Normal Operation:
Output Indicator Light (Green)

In Case of Overload Operation 
of Short-Circuit:
Overload Indicator Light (Red)

4.Switch on the equipment to be used.

in case of overload operation or when trouble occurs for the equipment being used, 

the output indicator light(green) will go out, the overload indicator light(red) will light 

continuously, and  no power will be put out.

At this time, the engine will not stop, so that the engine must be stopped by setting 

the respective engine switch to STOP.

CAUTION

  When equipment requiring a large starting power, like 

a motor etc., is used, the overload indicator light(red) 

and the output indicator light(green)may light together 

for a short time (about 4 sec),but this is  no abnormality. 

After start of the equipment, the overload indicator light 

(red) will go out and the output indicator light(green) 

will stay lit. 

CAUTION

2. Start each engine according to "STARTING THE ENGINE".

When the output indicator light(green)does not light and the overload indicator light 

(red)lights instead, set the engine switch to STOP, stop the engine at once and then 

start the engine again.

3. Confirm that the equipment to be used is switched off, and insert the plug of the 

equipment to be used into the AC receptacle of unit A or unit B.

1.Connect the ground terminal.

  Confirm that the use equipment to be connected is       

      switched off.

  When the equipment to be used is switched on, it will  

       operate suddenly, and injuries or accidents may be 

      caused.

Fuse

Fuse

Fuse

Fuse

Fuse

Fuse

Содержание Sinemaster IG2600

Страница 1: ...S I N E M A S T E R DIGITAL INVERTER GENERATOR IG2600 IG2600h WUXI KIPOR POWER CO LTD R R Fuse...

Страница 2: ......

Страница 3: ...or equipment damage if instructions are not followed NOTE Gives helpful information If a problem should arise or if you have any questions about the generator consult an authorized dealer Our generato...

Страница 4: ...13 SKETCH MAP IG2600h IG2600h movement state IG2600h placed state Fus e...

Страница 5: ...Pre operation Check 5 Starting the Engine High altitude operation 6 Generator Use 7 Stopping the Engine 8 Maintenance 9 Transporting Storage 10 Troubleshooting 11 Specifications 12 Electric diagram 1...

Страница 6: ...sumption g kW h Lube oil Single cylinder 4 stroke OHC gasoline engine 171cc 66x50mm 8 5 1 3 3 3600 T C I WR7DC Recoil starter Automotive unleaded gasoline 500 CD grade or SAE10W30 15W 40 Fuel tank cap...

Страница 7: ...on monoxide Never run the generator in an enclosed area The muffler becomes very hot during operation and remains hot for a while after stopping the engine Be careful not to touch the muffler while it...

Страница 8: ...rate the generator on a level surface If the generator is tiled fuel spillage may result Know how to stop the generator quickly and understand operation of all the controls Never permit anyone to op e...

Страница 9: ...to a suitable container c With the drain screw loosened remove the spark plug cap and pull the starter grip 3 to 4 times to drain the gasoline from the fuel pump d Turn the engine switch to the OFF po...

Страница 10: ...Do not overfill the tank there should be no fuel in the filler neck Do not operate the generator while it is on a vehicle Take the generator off the vehicle and use it in a well ventilated place Avoi...

Страница 11: ...1 Remove the four M5 screws and remove the muffler protector 2 Remove the muffler the spark arrester and the muffler gasket 3 Use a brush to remove carbon deposits from the spark arrester screen 4 Ch...

Страница 12: ...ly tightened plug can become very hot and possibly damage the generator Never use a spark plug with an improper heat range OFF Note Smart throttle system does not operate Engine speed is kept over rat...

Страница 13: ...vel is below the end of the dipstick refill the recommended oil up to the top of the oil filler neck 1 Check the engine oil level WARNING Using nondetergent oil or 2 stroke engine oil could shorten th...

Страница 14: ...asoline mixture or dirty gasoline Avoid getting dirt dust or water in the fuel tank After refueling tighten the fuel filler cap securely Note Note Please dispose of used motor oil in a manner that is...

Страница 15: ...Reinstall the left side maintenance cover and tighten the cover screw securely Make sure to turn the engine switch and the fuel cap lever OFF before draining CAUTION Check the air cleaner element to b...

Страница 16: ...eplace if necessary 3 1 Log hours of operation to determine proper maintenance 2 Service more frequently when used in dusty areas 3 These items should be serviced by an authorized dealer unless the ow...

Страница 17: ...l cap lever choke and the engine switch are OFF when stopping transporting and or storing the generator CAUTION NOTE Do not use the choke when the engine is warm or the air temperature is high 4 Pull...

Страница 18: ...ealer perform these carburetor modifications Even with suitable carburetor jetting engine horsepower will decrease approximately 3 5 for each 305m 1 000 feet increase in altitude The affect of altitud...

Страница 19: ...ttage of all appliances con nected must be considered Do not exceed the current limit specified for any one receptacle Do not connect the generator to a household circuit This could cause the damage t...

Страница 20: ...ng that continuously lights the over load indicator light red may damage the generator Marginal overloading that temporarily lights the over load indicator light red may shorten the service life of th...

Страница 21: ...ator light red stays on consult your generator dealer NOTE The DC receptacle may be used for charging 12 volt automotive type batteries only the zero load voltage is 15V 30V In DC operation turn the S...

Страница 22: ...oad indicator light red and the output indicator light green may light together for a short time about 4 sec but this is no abnormality After start of the equipment the overload indicator light red wi...

Отзывы: