Low oil alarm 

Indicator Light 

(Red)

Low oil alarm system

6.GENERATOR USE

WARNING

2

2

.

 To prevent electrical shock from faulty appliances, 

the generator should be grounded. Connect a length 

of heavy wire between the generator's ground 

terminal and an external ground source.

Connections for standby power to  a building's electrical 

system must be made by  a qualified electrician and must  

comply with all applicable laws  and electrical codes. 

improper connections can allow electrical  current from the 

generator to backfeed into the  utility lines. Such backfeed 

may electrocute utility company workers  or others who 

contact the lines during a  power outage, and when utility  

power is restored, the generator  may explode, burn, or 

cause fires in the building's  electrical system.  

 Maximum power is available in  the first 30 minutes. For  

continuous operation, do not exceed  the rated power. In 

either case, the total wattage  of all appliances con-nected 

must be considered.

Do not exceed the current limit specified for any one 

receptacle.

Do not connect the generator to a household circuit. This 

could cause the damage to the generator or to electrical 

appliances in the house.

       Do not modify or use the generator for other purposes than it is 

intended for. Also observe the following when using the 

generator.

   

D

 

o not connect generators in parallel.

    

D

 

o not connect an extension to the exhaust pipe.

     When an extension cable is required, be sure to use a tough 

rubber sheathed flexible cable.

Limit   length   of extension   cables; less   than 60 m   for   cables   

if   2.5mm  and   less   than 100m for cabes   of   4.0 mm

     Keep the generator away from other electric cables or wires 

such as commercial power supply lines.

 Electrical equipment(including lines and plug  connections) 

should not be defective.

CAUTION

The Low Oil alarm system is designed to prevent engine damage caused by an 
insufficient amount of oil in the crankcase. Before the oil level in the crankcase falls 
below a safe limit, the Low oil alarm system will automatically shut down the engine 
(the engine switch will remain in the ON position). 

Fuse

Содержание Sinemaster IG2600

Страница 1: ...S I N E M A S T E R DIGITAL INVERTER GENERATOR IG2600 IG2600h WUXI KIPOR POWER CO LTD R R Fuse...

Страница 2: ......

Страница 3: ...or equipment damage if instructions are not followed NOTE Gives helpful information If a problem should arise or if you have any questions about the generator consult an authorized dealer Our generato...

Страница 4: ...13 SKETCH MAP IG2600h IG2600h movement state IG2600h placed state Fus e...

Страница 5: ...Pre operation Check 5 Starting the Engine High altitude operation 6 Generator Use 7 Stopping the Engine 8 Maintenance 9 Transporting Storage 10 Troubleshooting 11 Specifications 12 Electric diagram 1...

Страница 6: ...sumption g kW h Lube oil Single cylinder 4 stroke OHC gasoline engine 171cc 66x50mm 8 5 1 3 3 3600 T C I WR7DC Recoil starter Automotive unleaded gasoline 500 CD grade or SAE10W30 15W 40 Fuel tank cap...

Страница 7: ...on monoxide Never run the generator in an enclosed area The muffler becomes very hot during operation and remains hot for a while after stopping the engine Be careful not to touch the muffler while it...

Страница 8: ...rate the generator on a level surface If the generator is tiled fuel spillage may result Know how to stop the generator quickly and understand operation of all the controls Never permit anyone to op e...

Страница 9: ...to a suitable container c With the drain screw loosened remove the spark plug cap and pull the starter grip 3 to 4 times to drain the gasoline from the fuel pump d Turn the engine switch to the OFF po...

Страница 10: ...Do not overfill the tank there should be no fuel in the filler neck Do not operate the generator while it is on a vehicle Take the generator off the vehicle and use it in a well ventilated place Avoi...

Страница 11: ...1 Remove the four M5 screws and remove the muffler protector 2 Remove the muffler the spark arrester and the muffler gasket 3 Use a brush to remove carbon deposits from the spark arrester screen 4 Ch...

Страница 12: ...ly tightened plug can become very hot and possibly damage the generator Never use a spark plug with an improper heat range OFF Note Smart throttle system does not operate Engine speed is kept over rat...

Страница 13: ...vel is below the end of the dipstick refill the recommended oil up to the top of the oil filler neck 1 Check the engine oil level WARNING Using nondetergent oil or 2 stroke engine oil could shorten th...

Страница 14: ...asoline mixture or dirty gasoline Avoid getting dirt dust or water in the fuel tank After refueling tighten the fuel filler cap securely Note Note Please dispose of used motor oil in a manner that is...

Страница 15: ...Reinstall the left side maintenance cover and tighten the cover screw securely Make sure to turn the engine switch and the fuel cap lever OFF before draining CAUTION Check the air cleaner element to b...

Страница 16: ...eplace if necessary 3 1 Log hours of operation to determine proper maintenance 2 Service more frequently when used in dusty areas 3 These items should be serviced by an authorized dealer unless the ow...

Страница 17: ...l cap lever choke and the engine switch are OFF when stopping transporting and or storing the generator CAUTION NOTE Do not use the choke when the engine is warm or the air temperature is high 4 Pull...

Страница 18: ...ealer perform these carburetor modifications Even with suitable carburetor jetting engine horsepower will decrease approximately 3 5 for each 305m 1 000 feet increase in altitude The affect of altitud...

Страница 19: ...ttage of all appliances con nected must be considered Do not exceed the current limit specified for any one receptacle Do not connect the generator to a household circuit This could cause the damage t...

Страница 20: ...ng that continuously lights the over load indicator light red may damage the generator Marginal overloading that temporarily lights the over load indicator light red may shorten the service life of th...

Страница 21: ...ator light red stays on consult your generator dealer NOTE The DC receptacle may be used for charging 12 volt automotive type batteries only the zero load voltage is 15V 30V In DC operation turn the S...

Страница 22: ...oad indicator light red and the output indicator light green may light together for a short time about 4 sec but this is no abnormality After start of the equipment the overload indicator light red wi...

Отзывы: