CAUTION
Running the starter motor for long time, it may consume the power, even destr-
oy the battery.
Put the start switch at the "ON" position while the engine is running.
CAUTION
Start switch
WARNING
4-1 Recoil starting
1.Start the engine according to the following
procedures:
Open the fuel cock.
Set the engine speed lever at the RUN position.
Remove hands from the startor switch after the
engine started , and the switch will return to the
RUN position automatically.
It will spend 10s to start, if the engine doesn't
start after 10s
please wait 15s to restart it.
You must check the electrolyte each month, if the electrolyte level is below the
lower limit line, please add the water to the upper limit line.
2. Battery
If the electrolyte is too little, the engine will not start. While if the electrolyte is
too much, the electrolyte will corrupt the parts. You should keep the electrolyte
level between the lower limit and upper limit.
Please tighten the screw on the cylinder to prevent any rainwater&dust,which
may cause wearing of inner parts as well as break-downs
7.1 Stop the generator set normally
1. Cut off the load
2. Turn off the air switch of the generator set
3. Turn off the engine switch, and turn the engine switch to "OFF" position
CAUTION
CAUTION
Don't use the "emergency stop button" in usual cases, which will do certain
harm to your generator.
7. STOP THE GENERATOR SET
In the case that the speeds handle is on "Stop" position, while the engine is
still running. You should turn the fuel switch to the "OFF" position, or loose the
high pressure oil pipe bolt to stop the engine.
Don't stop the engine with load; you should cut off the load first.
7.2 Emergency shut down
1. While the set is running, the operator should keep close watch on the running
state of the set. If there is anything abnormal, you should stop the set following
the right procedure.
2. If there is any emergency, it will result in big destroy or personal accident, such
as the set overspeed, short circuit, electric shock and so on. The operator should
stop the generator decidedly. Press the"emergency stop button", and the
generator will stop immediately.
3. Revolving the "emergency stop button" according to the arrow direction to
replace it.
Содержание K DE12000E