6
SENSOR OUTPUTS
The Geovane offers three types of outputs, summarized in the below table:
Output*
Number Data
Range
Comments
Frequency x1
True North
offset
10…130Hz
0-5V push-pull square
wave with 220Ω output
resistance
Analog
voltage
x2
True North
offset / Tilt X /
Tilt Y
0.5…4.5V
12-bit resolution with
220Ω output resistance
RS-485
x1
Refer to section
7.1
-
9600 bps 8N1, polled
*For information on pin connections see section 3.2.
6.1
Analog voltage outputs
Each of the two analog voltage outputs can be configured to one of the following:
True North offset.
Tilt X.
Tilt Y.
Both analog voltage signals are digitally generated by means of a 12-bit 0-5V
Digital to Analog Converter and subsequently conditioned by an analog output
stage with 220Ω output resistance. The output is constrained to the range 0.5-
4.5V, leading to the following characteristics:
Variable
Variable range
Voltage range
Resolution
True North offset
0…360º
0.5…4.5V
0.11º
Tilt X / Tilt Y
-90…90º
0.5…4.5V
0.05º
The first analog voltage output, Out (V1+), is located at pin 1.
The second analog voltage output, Out (V2+), is located at pin 5.
Both analog outputs reference its voltage to Out (V-), located at pin 8. In order to
ensure proper signal integrity, Out (V-) must never be connected to Supply(-) on
the sensor side. Otherwise the voltage drop in the negative power line will affect
the accuracy of the measurement.