General Vent Installation
This gas appliance is approved to be vented either through the side wall or vertically through the roof. Only Kingsman Flex(Z-
Flex)Venting Kits and components specifically approved and LABELED for this fireplace may be used.
Flex Pipe Venting
Kingsman Flex pipe is shipped in unexpanded length. When
installing pipe expand the lengths. Pipe can be expanded to
twice their lengths e.g. 4ft. to 8ft. Fully expand pipe and cut off
excess.
Do not use more than 2 couplers to extend short pipes. Single
sections are preferred in an installation attaching at the
fireplace and termination.
Place the spring spaces provided approximately every two feet
to stabilize 4” flex in the center of 7” flex. When forming bends
place spring in bend or before and after.
Horizontal runs require support metal straps every 2 feet. In off
set installation support straps should be used to stabilize pipe.
Expand 4” and 7” flex pipe to the point that the 7” protrudes
approximately 2 to 3 inches past outer wall and the 4” flex
protrudes approximately 2 to 3 inches past the 7” flex. Attach
the 4” pipe to the termination first and secure with sealant and
4 (four) screws then attach the 7” flex to the termination with
caulking and screws. Termination may then be moved
back to the outer wall and attached to home screwing into the
framing. Silicone around termination to waterproof. If siding
shield is going to be used attach this using same attaching
hole as the top of termination after termination has been
caulked for water proofing.
Use Hi Temp Sealant
Apply a bead of mill pac high temp sealant to all joints and use
four screws to secure each pipe at fireplace, termination and
any joint if joining any sections of pipe.
FRAMING DIMENSION
!
WARNING: DO NOT
mix parts from different systems unless stated in the manual.
Combustible Wall
Cut a 11” hole through exterior wall and frame as shown
below.
Non combustible Wall
Cut or drill 8” or 204mm diameter hole.
NOTE:
It is critical to the proper and safe operation of this
fireplace that on all connections the inner liner and the outer
casing are both caulked with liberal amounts of sealant. Do not
use any kind of tape or silicone other than that recommended in
this manual, Mill Pac Sealant.
If venting has been disassembled, reassemble and reseal in the
same manner as specified here.
Installation of Side Wall Venting
1. To determine the minimum distance from the bottom of the fireplace to
the center of the vent see page 8. Cut a hole through the wall allowing
for a 11” x 11” (inside diameter) in combustible walls for wall thimble or
an 8” diameter hole in a non-combustible wall (See Figure 2).
2. For the clearance to combustible above a 90 degree bend see
Clearance to Combustibles section.
3. Select the approximate vent length, precise measurements are not
needed as your flex pipe can be expanded to twice its shipped length
for ease of installation.
4. To install wall thimble centre over 11” x 11” (inch) framing from both
sides of wall and secure. Route flex vent pipe through wall thimble
(See Figure 1).
5. Before joining pipes, apply a bead of high temperature sealant (Mill
Pac) to end of pipe. First attach the four inch (4”) flue pipe to the vent
termination with sealant, and secure with 4 screws provided. At this
time make sure the spacer springs are attached to the (4”) flex pipe as
required. Then attach the seven inch (7”) pipe by the same method.
6. Mount vent termination and seal to wall using caulking around the wall
thimble to weather proof. After installing the vent termination, double
check to make sure the pipe extends properly through wall thimble and
into vent termination.
WARNING:
WHEN THE
HORIZONTAL VENT
TERMINATION IS
ACCESSIBLE A
CERTIFIED GUARD
(SAFETY CAGE
FDVHSCU) SHALL BE
INSTALLED.
7. Before joining pipes to fireplace flue, apply a bead of high temperature sealant (Mill Pac) to end of pipe. First attach the four inch
(4”) flue pipe to fireplace with Mill Pac sealant to the flue pipe and secure with 4 screws provided. At this time verify that the
spacer springs are attached properly to the (4”) flex pipe as required. Then attach the seven inch (7”) pipe by the same method.
8. Support horizontal pipes every two (2) feet (61 cm) with metal strap bands. Re-check fireplace to make sure it is levelled and
properly positioned and secured.
9. Support vertical pipes to maintain a minimum of 1” or greater clearance to combustibles with metal strapping bands.
10. If finishing the outside wall with vinyl or wood siding it is recommended that a Siding Shield be installed, Part Number ZDVSSLR.
11. A Termination Safety Cage (#FDVHSCU) is recommended.
47
Содержание ZRB46
Страница 31: ...Gas Conversion for Modulator PART C WARNING WARNING 31...
Страница 41: ...Configuration 1 Basic manual HI LO and manual ON OFF capabilities 41...
Страница 42: ...Receiver Module 584 523 521 221 1001 P221SI Receiver Module 584 523 521 221 1001 P221SI 42...
Страница 53: ...5 1 1 2 1 2 10 5 8 1 1 4 8 1 8 12 1 2 16 58PVH Dimensions 13 13 10 5 8 11 13 11 11 11 3 8 5 8 1 8 11 1 8 53...
Страница 63: ...PVCM Schematic Millivolt 63...
Страница 67: ...PVCM Schematic IPI 67...
Страница 68: ...68...