ZRB46 Clearance to Combustibles
Clearance to Combustibles ZRB46
Front 36”
[92cm]
Back (from Stand-offs)
0” [0cm]
Side (from Stand-offs)
0” [0cm]
Floor
*
0” [0cm]
Minimum Ceiling Height (from bottom of fireplace)
64” [162.5cm]
Top (from Stand-offs)
0” [0cm]
Top of 90° Bend in minimum Enclosure of 64”
8-1/2” [21.6cm]
Top of 90° Bend in Enclosure over 64”
4” [10.2cm]
VENTING SYSTEMS
Top of Horizontal Pipe
1/1/2” [3.8cm]
Side & Bottom of Horizontal Pipe
1” [2.5cm] All Vent Systems
Vertical Vent Pipe
1” [2.5cm] All Vent Systems
15
Содержание ZRB46
Страница 31: ...Gas Conversion for Modulator PART C WARNING WARNING 31...
Страница 41: ...Configuration 1 Basic manual HI LO and manual ON OFF capabilities 41...
Страница 42: ...Receiver Module 584 523 521 221 1001 P221SI Receiver Module 584 523 521 221 1001 P221SI 42...
Страница 53: ...5 1 1 2 1 2 10 5 8 1 1 4 8 1 8 12 1 2 16 58PVH Dimensions 13 13 10 5 8 11 13 11 11 11 3 8 5 8 1 8 11 1 8 53...
Страница 63: ...PVCM Schematic Millivolt 63...
Страница 67: ...PVCM Schematic IPI 67...
Страница 68: ...68...