46ZRB
Mantel
Clearances
Mantel Leg Clearances
-Combustible Objects on Non-
Combustible Mantel Warning-
Combustible objects must not be placed
on a Non-combustible Mantel unless the
mantel meets the dimensional
requirements for a Combustible Mantel.
Determine whether your mantel
conforms to the requirements of a
Combustible Mantel.
Before installing any mantels it is
important to determine the
combustibility of its material(s). There
are two types of mantels to consider:
Combustible and Non-Combustible.
A
Combustible Mantel
is one that
consists of material(s) that may
discolor, combust, or lose its integrity
in the presence of heat. These types
of mantels must strictly conform to the
dimensional requirements shown.
Conversely, a
Non-Combustible
Mantel
is one that is constructed with
material(s) that will not combust.
Check your local codes and
regulations to determine whether your
mantel is Combustible or Non-
Combustible.
The advantage to Non-Combustible
Mantels is that it may extend right up
to the tile lip of the fireplace.
Combustible mantels must adhere to
the dimensional restrictions shown.
Mantel Dimensions
are from front face
or Non-Combustible
Facing Materials
covering fireplace.
Top View
Adjacent Wall
Adjacent Wall
14
Содержание ZRB46
Страница 31: ...Gas Conversion for Modulator PART C WARNING WARNING 31...
Страница 41: ...Configuration 1 Basic manual HI LO and manual ON OFF capabilities 41...
Страница 42: ...Receiver Module 584 523 521 221 1001 P221SI Receiver Module 584 523 521 221 1001 P221SI 42...
Страница 53: ...5 1 1 2 1 2 10 5 8 1 1 4 8 1 8 12 1 2 16 58PVH Dimensions 13 13 10 5 8 11 13 11 11 11 3 8 5 8 1 8 11 1 8 53...
Страница 63: ...PVCM Schematic Millivolt 63...
Страница 67: ...PVCM Schematic IPI 67...
Страница 68: ...68...