With each insert the following must be pur-
chased:
(1) Log Set (4 pce) Cast or Fibre
(1) Standard Surround Kit
(1) Grill Kit
For a list of options please see page 18 and contact
your local dealer.
5. CODES AND LOCAL CODES
1. Installation should be in accordance with
applicable codes:
(CANADA) - Fuel Burning Installation
Code. Can./CGA-BI49.1 or .2
(USA.) . - National fuel gas ANSI -2223. 1
2. Electrical connections must be made in
accordance with the applicable codes and
the enclosed wiring diagram.
(CANADA) - Canadian Electrical Code
CSA-C22.1 part I
(USA.) -National Electrical Code
ANSI/NFPA no.70-1990
3. Local codes regarding wiring and instal-
lation of the unit must be observed.
6. CLEARANCES
This fireplace was designed for installation in a
solid fuel fireplace that has been installed in
accordance with National, Provincial/State and
Local building codes and is constructed of non-
combustible materials. DO NOT remove any
refractory materials from any
masonry
solid fuel
fireplace. For installation in
zero clearance
type
listed solid fuel burning factory built fireplaces, it
may be necessary to remove the damper plate and
refractory liners. Removal of the smoke baffle is
necessary in most cases.
Clearance from the front of the unit to a
combustible floor is 0.15 metres (6 inches).
Clearance from adjacent side wall is 7 inches
from side of unit.
•Minimum clearances from the top of the grill to a
mantel and maximum mantel width are:
MANTEL HEIGHT
ABOVE
UPPER
WIDTH GRILL
OPENING
A 7”(17.8cm)
13”(33.0cm)
B 6”(15.3cm)
12”(30.5cm)
C 5”( 12.7cm)
11”(27.9cm)
WARNING: The front of the fireplace gives
off high temperatures that could ignite
combustible material which is kept close
to the front of the unit.
7. ELECTRICAL CONNECTIONS
The blower for the fireplace insert comes pre-wired
from the factory all that is needed is to plug in to 120
volt supply.
Fan Temperature Sensor
The wiring harness has two wire ends that must be
attached to the Temperature Sensor. The
Temperature Sensor is mounted underneath the
burner, attached by two screws securing the
thermodisc to the bottom of the burner.
(See page 18 for drawing assembly of SIT Wiring
Diagram).
NOTE: MAKE SURE THE WIRE HARNESS IS
ROUTED AGAINST THE SURROUND,
NOT THE SIDE OF THE FIREPLACE.
Thermostat Connection and On/Off Switch
Millivolt Thermostat ( optional but recommended).
All controls are connected directly to the gas valve
and the circuit is made between:
• SIT Valve
TH
and
TP- TH, See Section 19
Grounding
When installed, the fireplace must be electrically
grounded in accordance with local codes, or in the
absence of local codes, with the National electrical
codes.