NOTE:

With a properly burning flame there

will still be a certain level of sooting. It may be
necessary to clean the glass up to 3 times
during a cold season. The amount of cleaning
required depends on the amount that the fire
place is used. 

15. MAINTENANCE 

CAUTION:

Label all wires prior to 

disconnection when servicing controls. Wiring 
errors can cause improper and dangerous 
operation. Verify proper operation after 
servicing. 

WARNING: 

INSURE THAT POWER IS 

TURNED OFF TO THE FIREPLACE 
BEFORE SERVICING. 

(a) Blower 

This motor has been factory oiled and under
normal operating conditions should not require
oiling. 

Replacement of Blower 

Remove glass (two screws behind upper grill), and
remove logs. Blower access panel is visible after
rear log is removed. Remove the screws (five on
top, one on each side) and lift from tabs, blower is
then assessable for servicing. Before re-installing
blower access panel, apply a bead of sealant
Millpac to the bottom edge of panel, (this is to
assure blower does not interfere with combustion).
and than secure with screws. 

(b) Burner/Pilot 

The burner should be periodically cleaned by
removing any ember material and wiping off and
vacuuming the burner pan. At this time it is also
recommended to check the burner for any signs of
corrosion which might impair its operation and
replace it if necessary. 

The pilot should also be checked for signs of
proper operation and flame. 

If replacement of 

pilot, generator, thermocouple is necessary replace
from top and bottom of firebox bottom.

(Reference lower diagram Page 18) 

(c) Logs 

CAUTION: The logs can stay hot for several
hours after the fireplace is shut off. Serious
burns could result. It is recommended that the
fireplace be turned off for several hours before 
cleaning is attempted. 

DO NOT

wash the logs if they have any

accumulation of soot on them. Washing the logs in
any sort of solution will just cause the soot to
become imbedded in the logs surface. 

The best way to clean the logs is to blow off the
soot using compressed air at high velocity. It is
also effective to use a clean soft brush in the area
of soot accumulation. Vacuuming the log with a
soft brush will also work but do not forget to
carefully wash the brush before using it on
anything else. If at all possible clean the logs
outside the home away from areas you do not wish
the soot to mark. 

(d) Firebox and Heat Exchanger 

To clean the firebox and heat exchanger use a
vacuum. For the firebox it is recommended to use
a soft brush on the end of the vacuum as not to
damage any painted surfaces. The heat exchanger
may be more difficult to clean but can still be
cleaned with the combination of a small brush and
the vacuum. 

(e) Glass 

It will be necessary to clean the glass periodically.
During start-up it is normal for condensation to
form on the glass and cause dirt, soot, lint etc., to
adhere to the inner surface of the glass. There also
will be a film deposited on the glass during the
initial use of the fireplace due to initial curing of
the paint. It is recommended that the glass be
cleaned with a non-abrasive household cleaner and
warm water. 

Содержание VFI25LP

Страница 1: ...anual Installation and service must be performed by a qualified installer service agency or the gas supplier Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this...

Страница 2: ...wn between each Be aware during log and firebox paint curing that a white deposit may be developing on the inside of the glass doors It is important to remove this white deposit from the glass doors w...

Страница 3: ...0 11 Field Conversion for C30GEK 11 12 Combustion Air Unit Operation Checkout 12 14 Unit Adjustment 13 15 Maintenance 14 16 Surround and Brass Trim Assembly Instructions and Parts List 15 17 Surround...

Страница 4: ...variable gas input 3 HEAT OUTPUT It must be remembered that both the units in this manual produce significant amounts of heat within a varying input range VFI25N NATURAL GAS 0 4500ft Output BTU HR In...

Страница 5: ...the front of the unit to a combustible floor is 0 15 metres 6 inches Clearance from adjacent side wall is 7 inches from side of unit Minimum clearances from the top of the grill to a mantel and maxim...

Страница 6: ...imney or other approved venting system the chimney must be inspected cleaned and rep aired if necessary A chimney which was used for a solid fuel fireplace must be professionally cleaned in order to r...

Страница 7: ...in place 19 is required 6 If the lintel is wider than 12 305mm then the height of the solid fuel fireplace must be at least 25 63 5 cm to allow for an offset elbow See Figure 2 If providing an offset...

Страница 8: ...solid fuel fireplace Make sure that the fireplace is completely cool and has not been used for a few days 7 Make sure that the solid fuel fireplace base is level and if not make any necessary adjustm...

Страница 9: ...and pull forward to the grate bars Place log 2 on rear log holder and center it Step 3 Place Log 3 onto the notched areas as shown Place Log 4 onto the notched areas as shown Refer to step 2 for notch...

Страница 10: ...to step 2 for Log 5 notch locations Fill the exposed areas of the ember plates and front burner tube with ember rocks Do not place ember rocks on rear burner tube Step 4 Place lava rock around the sid...

Страница 11: ...rill 1 8 Drill Bit 1 4 Nut Driver Bit Step 1 Remove existing grate bar by bending bar slightly forward and drill out rivets Step 2 Seal rivet holes with two supplied screws ZDV6000 ONLY Step 3 Center...

Страница 12: ...not be allowed to contact glass and unit should be allowed to run for a minimum of 10 minutes area of sensing tube will become quite hot A minimum draft pressure of 02 inches of water column is requi...

Страница 13: ...left of the valve E Inlet Pressure and A Manifold Pressure and connecting a manometer Pressure ranges are as listed below Gas Supply Pressure inches w c Min Normal Max Natural Gas 4 5 7 0 9 0 L P pro...

Страница 14: ...ple is necessary replace from top and bottom of firebox bottom Reference lower diagram Page 18 c Logs CAUTION The logs can stay hot for several hours after the fireplace is shut off Serious burns coul...

Страница 15: ...placement For valve replacement it is recommended that the burner assembly be removed this is done by removing two 1 4 hex screws on the left and right side of the firebox and lifting the complete bur...

Страница 16: ...ure all panels All brass trims D E and F are installed with 5 16 x 6 32 self tapping screws attach part D E and F to outer edge of surround Than place On Off switch into slot upper right corner after...

Страница 17: ...Brass Trim Top 1 E 3000 305 3000 315 3000 330 Brass Trim Left 1 F 3000 306 3000 316 3000 329 Brass Trim Right 1 G 3000 307 3000 317 3000 324 Brass Panel Top 1 Gl n a n a 3000 327 Brass Panel Bottom 1...

Страница 18: ...ITCH Wiring Diagram SIT 820 639 and 820 640 True Millivolt Systems This System does not have a thermocouple For units with serial number greater than 13930 see 820639 820640 systems Wiring diagram wit...

Страница 19: ...Kit Antique Brass V25T2129C Trim Kit Chrome V25T2129P Trim Kit Polish Brass Size 21 High x 29 Wide V25S2738B Surround Kit Large Flat Black V25T2738A Trim Kit Antique Brass V25T2738C Trim Kit Chrome V...

Страница 20: ...ts are not available for Deluxe Surrounds V25ADDX Arch Door Frame Deluxe Black 352 V25ADTH Arch Door Frame Top Half Black 353T V25ADDA Arch Door Frame Double Arch Black 354 V25ADDD Arch Door Frame Dou...

Страница 21: ...P136WR Thermopile GOAI 524 1001 P069SI Electrode Sparker 915 069 TC SIT 1001 P216SI Thermocouple 290 216 TC SIT 1001 P165SI Orifice Pilot NG 977 165 TC SIT 1001 P167SI Orifice Pilot LP 977 167 TC SIT...

Страница 22: ...Hood Assembly 2000 079 Gasket for Flue 2500 BNGSI Burner Assy c w Valve Natural Gas 2500 BLPSI Burner Assy c w Valve Liquid Propane 3000 930 Spill Safety Switch 36T21 3000 940 Glass Robax 23 22 x 11 7...

Страница 23: ...ot screw to provide proper sized flame Recommended Maximum Lead Length Double Wire When Using Wall Switch or Thermostat Wire Size Max Length 14 GA 100 FT 16 GA 64 FT 18 GA 40 FT 20 GA 25 FT 22 GA 16 F...

Страница 24: ...service or maintenance h damage repairs inoperation or inefficiency resulting from faulty installation or application i electricity or fuel costs or any increase in electricity or fuel cost whatsoeve...

Отзывы: