background image

BASIC ONE YEAR WARRANTY

During the first year after installation, we will provide a replacement for any component part of your unit found to be defective in materials 
or workmanship, including labour costs. Repair work requires prior approval by Kingsman, labour costs are based on a predetermined rate
schedule and any repair work must be done through an authorized Kingsman dealer.

LIMITED LIFETIME WARRANTY

The heat exchanger, combustion chamber and burner of every Kingsman product excluding the Outdoor Firepit are warranted against 
materials or workmanship during the period the product is owned by the original owner. The part to be replaced must be returned to our 
distributor in exchange for the replacement part. Any labor, material, freight and/or handling charges associated with any repair 
or replacement pursuant to this Limited Lifetime Warranty will not be covered by this warranty.

GENERAL TERMS

In lieu of providing a replacement part, we may, at our option, provide the distributor's component purchase price from us or a credit equal 
to the distributors component purchase price from us toward the purchase of any new unit which we distribute. If a credit is given 
in lieu of a replacement part, the rating plate from the unit being replaced must be submitted on a warranty claim, and the unit being
replaced must be made available to our distributor for disposition.

In establishing the date of installation for any purpose, including determination of the starting date for the term of this Limited Lifetime
Warranty, reasonable proof of the original installation date must be presented*, otherwise the effective date will be based upon the date of
manufacture plus thirty (30) days.

We will not be responsible for and you, the user, will pay for: (a) damages caused by accident, abuse, negligence, misuse, riot, fire, flood,
or Acts of God (b) damages caused by operating the unit where there is a corrosive atmosphere containing chlorine, fluorine, or any other 
damaging chemicals (other than in a normal residential environment) (c) damages caused by any unauthorized alteration or repair 
of the unit affecting its stability or performance (d) damages caused by improper matching or application of the unit or the unit's components
(e) damages caused by failing to provide proper maintenance and service to the unit (f) any expenses incurred for erecting, disconnecting 
or dismantling the unit (g) parts or supplies used in connection with service or maintenance (h) damage repairs, inoperation or inefficiency
resulting from faulty installation or application (i) electricity or fuel costs or any increase in electricity or fuel cost whatsoever including 
additional or unusual use of supplemental electric heat.

We shall not be liable for any incidental, consequential, or special damages or expenses in connection with any use or failure of this unit. 
We have not made and do not make any representation or warranty of fitness for a particular use or purpose, and there is no implied condition
of fitness for a particular use or purpose. We make no express warranties except as stated in this Limited Lifetime Warranty. No one is authorized
to change this Limited Lifetime Warranty or to create for us any other obligation or liability in connections with this unit. Any implied 
warranties shall last for one year after the original installation. Some states and provinces do not allow the exclusion or limitation of incidental 
or consequential damages or do not allow limitations on how long an implied warranty or condition lasts, so the above limitations or exclu-
sions may not apply to you. The provisions of this limited warranty are in additions to and not a modification of or subtraction from any statu-
tory warranties and other rights and remedies provided by law.

Save this certificate. It gives you specific legal rights, and you may also have other rights which may vary from state to state and province to province.

In the event your unit needs servicing, contact your dealer or contractor who installed or serviced your unit. When requesting service, 
please have the model and serial number from each unit readily available. If your dealer needs assistance, the distributor is available for support
and we, in turn support the distributor's efforts.

Fill in the installation date and model and serial numbers of the unit in the space provided below and retain this limited warranty for your files.

Model No.

Serial No.

Date installed

Dealer or Contractor Name:

*To receive advantage of your warranty, you must retain the original records that can establish the installation date of your unit.

LIMITED LIFETIME WARRANTY

This Limited Lifetime Warranty applies only while the unit remains at the site of the original
installation and only if the unit is installed inside the continental United States, Alaska, Hawaii,
and Canada. The warranty applies only if the unit is installed and operated in accordance 
with the printed instructions and in compliance with applicable installation and building codes 
and good trade practices.

The Ultimate in Design, Engineering & Quality

Содержание VFI25

Страница 1: ...ractory materials from any masonry solid fuel fireplace The VFI25 Fireplace Insert was designed for installation in a zero clearance type listed solid fuel burning factory built fireplace It may be ne...

Страница 2: ...use odours It is recommended that you burn your gas fireplace or stove for a minimum of four hours at a time with the fan off after the curing of the paint has been completed These odours can last upw...

Страница 3: ...C6 Placement Guidelines 12 Burner System Maintenance 13 VFI25 Conversion Kit Instructions Part A 13 VFI25 VFI30 Conversion Kit Instructions Part A 14 Gas Conversion for Top Convertible Pilot Series 01...

Страница 4: ...nt see diagram above to secure the appliance to the floor Bedroom approved Warning Do not compromise the structural integrity of the manufactured home wall floor or ceiling during installation of appl...

Страница 5: ...ing the appliance 15 Installation and repair should be done by a qualified service person The appliance should be inspected before use and at least annually by a professional service person More frequ...

Страница 6: ...domestic hot water equipment where the bottom of the vent terminal and the air intake is installed below four feet above grade the following requirements must be satisfied A If there is not one alread...

Страница 7: ...liners Removal of the smoke baffle is necessary in most cases Clearance from the front of the unit to a combustible floor is 0 15 metres 6 inches Clearance from adjacent side wall is 7 inches from si...

Страница 8: ...run through a masonry chimney or other approved venting system the chimney must be inspected cleaned and repaired if necessary A chimney which was used for a solid fuel fireplace must be professionall...

Страница 9: ...in place 19 is required 6 If the lintel is wider than 12 305mm then the height of the solid fuel fireplace must be at least 25 63 5 cm to allow for an offset elbow See Figure 2 If providing an offset...

Страница 10: ...solid fuel fireplace Make sure that the fireplace is completely cool and has not been used for a few days 7 Make sure that the solid fuel fireplace base is level and if not make any necessary adjustm...

Страница 11: ...s Place log 2 on rear log holder and center it Step 3 Place Log 3 onto the notched areas as shown Place Log 4 onto the notched areas as shown Refer to step 2 for notched area locations Step 4 Place la...

Страница 12: ...ocations Fill the exposed areas of the ember plates and front burner tube with ember rocks Do not place ember rocks on rear burner tube Step 4 Place lava rock around the sides and front of the burner...

Страница 13: ...n on the unit at least once a month and inspect the flame pattern to ensure there are no problems with the burner tube The pilot flame should also be inspected monthly to ensure proper operation Flame...

Страница 14: ...pplied with the Conversion Kit IMPORTANT Always check for gas leaks with a soap and water solution DO NOT USE OPEN FLAME FOR LEAK TESTING WARNING This conversion kit shall be installed by a qualified...

Страница 15: ...e new injector is proper for the application The injector size is stamped on the side of the injector near the top LPG injectors have a groove machined around their circumference near the top while NG...

Страница 16: ...Gas Conversion for Modulator PART C 16...

Страница 17: ...orward and drill out rivets Step 2 Seal rivet holes with two supplied screws ZDV6000 ONLY Step 3 Center legs of Grate Bar on either side of burner support and fasten with supplied self drilling Screws...

Страница 18: ...ot be allowed to contact glass and unit should be allowed to run for a minimum of 10 minutes area of sensing tube will become quite hot A minimum draft pressure of 02 inches of water column is require...

Страница 19: ...ame size is factory set The pilot flame should be at least 1 5 inches 4 cm long The flame should be impinging on the pilot generator Pilot size can be adjusted through the pilot adjust screw If the pi...

Страница 20: ...of a filmy residue It is therfore rec ommended that the glass be cleaned two or three times initially with non abrasive common household glass cleansers and warm water After that the glass can be cle...

Страница 21: ...he firebox and lifting the complete burner assembly from the unit and replacing defective component and re installing Check for gas leaks after replacing burner assembly WARNING No substitute material...

Страница 22: ...all panels All brass trims D E and F are installed with 5 16 x 6 32 self tapping screws attach part D E and F to outer edge of surround Than place On Off switch into slot upper right corner after tri...

Страница 23: ...ass Trim Top 1 E 3000 305 3000 315 3000 330 Brass Trim Left 1 F 3000 306 3000 316 3000 329 Brass Trim Right 1 G 3000 307 3000 317 3000 324 Brass Panel Top1 Gl n a n a 3000 327 Brass Panel Bottom 1 H 3...

Страница 24: ...H Wiring Diagram SIT 820 639 and 820 640 True Millivolt Systems This System does not have a thermocouple For units with serial number greater than 13930 see 820639 820640 systems Wiring diagram with T...

Страница 25: ...t Antique Brass V25T2129C Trim Kit Chrome V25T2129P Trim Kit Polish Brass Size 21 High x 29 Wide V25S2738B Surround Kit Large Flat Black V25T2738A Trim Kit Antique Brass V25T2738C Trim Kit Chrome V25T...

Страница 26: ...are not available for Deluxe Surrounds V25ADDX Arch Door Frame Deluxe Black 352 V25ADTH Arch Door Frame Top Half Black 353T V25ADDA Arch Door Frame Double Arch Black 354 V25ADDD Arch Door Frame Double...

Страница 27: ...36WR Thermopile GOAI 524 1001 P069SI Electrode Sparker 915 069 TC SIT 1001 P216SI Thermocouple 290 216 TC SIT 1001 P165SI Orifice Pilot NG 977 165 TC SIT 1001 P167SI Orifice Pilot LP 977 167 TC SIT 10...

Страница 28: ...d Assembly 2000 079 Gasket for Flue 2500 BNGSI Burner Assy c w Valve Natural Gas 2500 BLPSI Burner Assy c w Valve Liquid Propane 3000 930 Spill Safety Switch 36T21 3000 940 Glass Robax 23 22 x 11 75 3...

Страница 29: ...screw to provide proper sized flame Recommended Maximum Lead Length Double Wire When Using Wall Switch or Thermostat Wire Size Max Length 14 GA 100 FT 16 GA 64 FT 18 GA 40 FT 20 GA 25 FT 22 GA 16 FT C...

Страница 30: ...service or maintenance h damage repairs inoperation or inefficiency resulting from faulty installation or application i electricity or fuel costs or any increase in electricity or fuel cost whatsoeve...

Отзывы: