Kingsman MQZCV48LP Скачать руководство пользователя страница 38

RBCB1   -Cannonballs-   Installation Instructions 

*Must be used with MQZCV48GT Glass Tray 

Assorted size and colors. Place randomly as desired inside fireplace. 

 

Can be used with MQ Glass, MQ Ember, and / or Lava Rock. 

Do not place Cannonballs directly on burner ports.  

If sooting occurs change position of or remove affected objects. 

 

MQ Glass can be placed directly on Burner and on Glass Tray. 

 

MQ Ember can be placed directly on Burner Only. 

 

Lava Rock (Supplied with Base Unit) CANNOT be placed on Burner. 

Place Lava Rock in channel in front of 

Glass Tray & on Glass Tray.

 

 

 
 

 

 

NOTE

 

 

Pilot Area Must Not Be Covered, as delayed ignition can occur. 

 Do not place Cannonballs directly on burner ports.

 

Pilot Area Must Not 

Be Covered

 

38

Содержание MQZCV48LP

Страница 1: ...or the gas supplier Installation Instructions This appliance may be installed in an aftermarket permanently located manufactured home USA only or mobile home where not prohibited by local codes This...

Страница 2: ...l Tile Lip Kit 22 MQZCV48 Mantel Clearances 23 ACCESSORIES MQZCV48 51UHS Box 24 Component Locations 25 MQZCV48 Z46FK Fan Kit Installation 26 Fan Speed Control Outside of Fireplace 27 ZCV48PL Porcelain...

Страница 3: ...ronic Ignition Lighting Instructions 61 IPI SYSTEM 2 Proflame 2 Parts List 62 Proflame 2 IFC Module and Remote Control 63 Cold Climates CPI Setting Proflame 2 Remote Control 64 Proflame 2 Remote Contr...

Страница 4: ...keep toddlers young children and other at risk individuals out of the room and away from hot surfaces Do not leave the fireplace remote control where it is accessible to children Termination Cap Safet...

Страница 5: ...annually by a professional service person More frequent cleaning may be required due to excessive lint from carpeting bedding material et cetera It is imperative that control compartments burners and...

Страница 6: ...ication plate shall be mounted at the exterior of the building four feet directly above the location of vent terminal The plate shall be of sufficient size to be easily read from a distance of eight f...

Страница 7: ...e sounds produced by a furnace or heating duct This noise does not affect the operation or longevity of your fireplace It is also normal for the fan to make some noise when it comes on This noise can...

Страница 8: ...r to the indoor gas fireplace being installed A Minimum sheltering cover overhang of 1 2 the distance from the base of the fireplace to the ceiling base of roofline is required EXAMPLE The bottom of t...

Страница 9: ...nadian National Electrical Code in Canada An appliance must be grounded to the steel chassis of the home with 8 ga copper wire using a serrated or star washer to penetrate paint or protective coating...

Страница 10: ...te of where the stand off locations are These stand offs are provided as indicators to illustrate the boundaries for framing Therefore no framing material is permitted to extend beyond these stand off...

Страница 11: ...replace Fireplace to be covered with Non Combustibles e g Concrete Board for Flat Wall appearance Qty 2 Nailing Tabs are located on each side of the front frame Nailing Tab Framing Stud Drywall Non Co...

Страница 12: ...Divider E Flat on Wall Corner F Exterior Wall See Mantel Leg Clearances Instruction for the proper placement of fireplace Island installation with a top vent is possible as long as the horizontal por...

Страница 13: ...4 Per Foot Vertical Venting MUST maintain 1 clearance to combustibles These structures are not load bearing RIGHT SIDE For Propane Horizontal installations the venting must be an additional one foot a...

Страница 14: ...in Enclosure over 66 6 15cm VENTING SYSTEMS Top of Horizontal Pipe 1 1 2 3 8cm Side Bottom of Horizontal Pipe 1 2 5cm All Vent Systems Vertical Vent Pipe 1 2 5cm All Vent Systems Note If appliance is...

Страница 15: ...ace for durability Finishing Recommendations Obtained from professional construction contractors and finishers Frame unit with metal studs minimum 20 gauge Wooden studs may be used but may cause drywa...

Страница 16: ...lace face Step 2 Use concrete board to cover face of fireplace NOTE Leave clearance of 1 3 16 on top and 1 1 16 on both sides and bottom to install and remove screen A Tile Lip Kit is Available Part N...

Страница 17: ...before touching glass or attempting to install or remove Child Safety Screen Screen is locked in place Contents of Kit 1 Child Safety Screen Ready to Install Assembly Instructions Attach screen to fir...

Страница 18: ...Drywall will be flush with fireplace face Drywall 4 1 8 MIN 4 MIN ZCV48 Fireplace Opening ZCV47S1BL Surround To Attach Surround to Screen 1 Place surround face down on protected surface 2 Lay Screen o...

Страница 19: ...ening below IMPORTANT NOTE When installing stone brick or other material around the perimeter of the surround You MUST Leave 2 5 8 of the fireplace face exposed around the fireplace opening on the Sid...

Страница 20: ...ZCV48 Fireplace Opening Required Clearance ZCV48 Fireplace Opening Required Clearance 20...

Страница 21: ...LK Follow instructions included with kit to use Back frame can be installed and used as tile lip also To Assemble Designer Door 1 Slide Screen into Front Frame 2 Set Hinge Sockets on Front Frame onto...

Страница 22: ...clearance from fireplace opening MQZCV48 TLK Cut Lengths Fireplace Facing Choice Height of Side Pieces Side Clearance from Opening Length of Top Bottom Pieces Top Clearance from Opening Bottom Clearan...

Страница 23: ...Non Combustible The advantage to Non Combustible Mantels is that it may extend right up to the tile lip of the fireplace Combustible mantels must adhere to the dimensional restrictions shown Combustib...

Страница 24: ...ed from beneath fireplace through access panel opening Remove glass door first NOTE When using a remote control the 51 UHS must be used Batteries for Remote Receiver can be changed by lifting 51 UHS u...

Страница 25: ...ORIFICE JUNCTION BOX VALVE ULK LIGHT KIT TRANSFORMER IPI SYSTEM 2 MODULE BATTERY BACKUP Gas line Gas line UHS BOX UHS BOX NOTE The gas line connection may be made of 1 2 rigid pipe or an Approved Kin...

Страница 26: ...under Burner pan WARNING Electrical Grounding Instructions This appliance is equipped with a three prong grounding plug for your protection against shock hazard and should be plugged directly into a...

Страница 27: ...pronged grounding plug for your protection against shock hazard and should be plugged directly into a properly grounded three prong receptacle Label all wires prior to disconnection when servicing con...

Страница 28: ...Clips Step Five Reinstall Liner Supports and Screws WARNING Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may...

Страница 29: ...tep One Place Back Liner against back wall of firebox Step Two Remove Brick Clips located in upper sides of firebox WARNING Failure to position the parts in accordance with these diagrams or failure t...

Страница 30: ...ay over Burner Attach with two DT Screws from Log Holder DO NOT COVER PILOT SHIELD AREA WITH MEDIA WARNING Failure to position the parts in accordance with these diagrams or failure to use only parts...

Страница 31: ...MQZCV48GT Cutting Liners for use with Glass Tray Cut shaded areas off and discard Liners will sit on top of Glass Tray 31...

Страница 32: ...A C22 1 Canadian National Electrical Code in Canada Contents of Kit 4 12V Halogen Lamps Lamp Plate with Insulated Studs wiring 12VAC Transformer with 3 prong plug wire connectors Light Switch Cover Pl...

Страница 33: ...n Replace Burner Ember Plate and Grate Bar Lamp Setup for MQZCV48GT Glass Tray STEP 4 Place Lamps in firebox as shown above Rear Lamps and Front Lamps are all pointing upward Attach Lamp Mount Bracket...

Страница 34: ...RNING Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage or personal injury NOTE THESE...

Страница 35: ...wn Place LOG 8 between the Grate Bars on the right side TOP VIEW Lava Rock Vermiculite on Firebox Bottom If Crushed Glass and Light Kit are used place Glass onto front area of Burner above lights Embe...

Страница 36: ...TE THESE ITEMS ARE SUPPLIED WITH THE FIREPLACE LOG 1 LOG 2 LOG 3 LOG 4 LOG 6 LOG 7 LOG 5 LOG 8 LOG 1 LOG 2 LOG 3 STEP 1 STEP 2 STEP 3 STEP 4 Embers Lava Rock Vermiculite Insulation Wool LOG 9 If Crush...

Страница 37: ...Setup is complete WARNING Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage or person...

Страница 38: ...rts If sooting occurs change position of or remove affected objects MQ Glass can be placed directly on Burner and on Glass Tray MQ Ember can be placed directly on Burner Only Lava Rock Supplied with B...

Страница 39: ...quid Glass from Firegear Maximum amount MQZCV48 Natural gas is 25 lbs Not recommended for Propane appliances MQG5W Decorative Glass 1 2 White MQG5A Decorative Ember Glass Cobalt Blue MQG5B Decorative...

Страница 40: ...ition of or remove affected objects MQEMBER To be placed directly on Burner and Burner Ports Place these glowing ember chunks randomly May be used with or without other accessories MQRock2 Or MQRock3...

Страница 41: ...1 is placed against back wall of firebox Log 2 is placed against left side wall of firebox and onto front edge of burner and up against Log Tab 1 Log 3 is placed on right side of firebox against back...

Страница 42: ...Embers Lava Rock Insulation Wool on Burner Lava Rock Vermiculite on Firebox Bottom If Crushed Glass and Light Kit are used place Glass onto front area of Burner and over left and right rear lights 42...

Страница 43: ...lower latches at an angle of between 15 and 30 degrees 3 Swing door up and pull top latches over door lip at each corner 4 Replace Access Cover below Glass Door 30 15 WARNING Wait until unit is COMPLE...

Страница 44: ...lass Wear gloves Removal of the Glass Door 1 Remove the door by unlatching the 2 top latches Simply place 2 fingers in the grooves and pull and lift upward slightly 2 Once the top of the door is unlat...

Страница 45: ...any pressure testing of that system at test pressures in excess of 1 2 PSIG 3 5 KPa 9 The appliance must be isolated from the gas supply piping system by closing its individual shutoff valve during a...

Страница 46: ...observe closely the pilot burner located on the rear center left hand side of the main burner If a flame has appeared then continue to depress the control knob for 20 seconds If the flame did not app...

Страница 47: ...ition of vent and vent terminal for sooting or obstruction and correct if present 6 Vacuum and clean any debris in the firebox that is not supposed to be there 7 Test and measure the flame failure res...

Страница 48: ...Check generator with millivolt meter Take reading at generator terminals of gas valve Should read 325 millivolts minimum while holding valve knob depressed in pilot position and wall switch off Replac...

Страница 49: ...Brass Nipple Air Shutter Hi Lo Regulator 48ZCV CKLPH LP Conversion Millivolt 1001 P167SI 30 977 167 46 1000 253 closed 1000 253 closed Fully Open 1001 P202SI 0 907 202 48ZCV CKNGH NG Conversion Milli...

Страница 50: ...IMPORTANT Always check for gas leaks with a soap and water solution DO NOT USE OPEN FLAME FOR LEAK TESTING Warning This conversion kit shall be installed by a qualified service agency in accordance wi...

Страница 51: ...ector near the top LPG injectors have a groove machined around their circumference near the top while NG injectors do not have a groove fig 4 Refer to the Appliance Manufacturer s instruction sheet fo...

Страница 52: ...Gas Conversion for Modulator PART C 52...

Страница 53: ...k the burner pan loose lift the assembly upward to remove it from the firebox cavity Installation is the reverse of these steps Ensure that the mounting surface is clean Use fresh Black Mill Pac to re...

Страница 54: ...ck This component permits the IPI system to operate without the need for an external AC Adapter power source The advantage to using the battery backup is that in the case of a power failure the applia...

Страница 55: ...ctivate this function press the Thermostat Key The LCD display on the Transmitter will change to show that the room thermostat is ON and the set temperature is now displayed To adjust the set temperat...

Страница 56: ...or 1002 P910si Electrode Flame Sensor 35 Length 5 1002 P302si IPI Ignition Board 6 1002 P850si AC Wall Adapter 7 1002 P12BH Battery Pack 8 1002 P912si Wiring Harness 9 1001 P166si Orifice Pilot NG 62...

Страница 57: ...Configuration 1 Basic manual HI LO and manual ON OFF capabilities 57...

Страница 58: ...Receiver Module 584 523 521 221 1001 P221SI Receiver Module 584 523 521 221 1001 P221SI 58...

Страница 59: ...er Adapter P N 1002 P850si The Remote Receiver IPI or Millivolt system can be powered by the AC Adapter This is advantageous if you do not want to use batteries Simply connect the AC Adapter into the...

Страница 60: ...Configuration 3 Remote ON OFF variable HI LO and fan capabilities Refer to the fan installation removal section for fan installation 60...

Страница 61: ...e department LIGHTING INSTRUCTIONS 1 Stop Read the above safety information on this label 2 Remove batteries from receiver and or Battery Backup Pack 3 Turn off all electric power to the fireplace 4 T...

Страница 62: ...13 1002 P047SI TC Pilot Burner IPI Assembled LP 199 047 14 1001 P166SI TC Orifice Pilot NG 977 166 62 IPI 15 1001 P168SI TC Orifice Pilot LP 977 168 35 IPI 16 1001 P280SI TC Tubing W Fittings 1 8 2 1...

Страница 63: ...must be followed to reset the PF2 Module Press the Red SW1 button until you hear three beeps Within 10 seconds press the SW1 button again until you hear it beep The PF2 Module may now be turned on off...

Страница 64: ...ON OFF and the pilot is also out follow the procedures described in this manual to light the pilot To switch from IPI to CPI Mode 1 Turn the fireplace OFF using the ON OFF Key 2 Press the Mode Key Dis...

Страница 65: ...Proflame 2 Remote Control 65...

Страница 66: ...Note When Smart Thermostat is activated manual flame height adjustment is disabled Note This function is only available in Room Thermostat or Smart Thermostat Control Mode 66...

Страница 67: ...67...

Страница 68: ...u h 3 kW and 50 000 Btu h 15 kW 12 in 30 cm for appliances 50 000 Btu h 15 kW K Clearance to a mechanical air supply inlet 6 ft 1 83 m 3 ft 91 cm above if within 10 ft 3 m horizontally L Clearance abo...

Страница 69: ...of fireplace to center of vent see the Framing Your Gas Fireplace section Cut a hole through the wall allowing for a 12 x 12 inside diameter in combustible walls for wall thimble or a 9 diameter hole...

Страница 70: ...ht of the system and the number of bends required 2 Having determined the vertical distance determine the maxi mum horizontal section allowed 3 Vent table has been established for 90 horizontal vertic...

Страница 71: ...a Roof Flashing suitable to your roof slope over the vent Place the edge of the flashing plate that will be on the higher part of the roof slope under the shingles Both the sides and the lower edge l...

Страница 72: ...ough roof support configuration B Flex bend configuration C Termination mounting A B C 24 Clearance to perpendicular wall 24 inches 60 cm Recommended to prevent re circulation of exhaust products For...

Страница 73: ...s are permitted however Cold Climate Switch Standing Pilot Mode must NOT be used Seven 90 elbows are possible if the total horizontal is not more than 25ft and the vertical does not exceed 15ft Refer...

Страница 74: ...ded 5 Expanded Z58FK8 Flex Kit 5 8 Dia x 4 Unexpanded 8 Expanded Z58FK20 Flex Kit 5 8 Dia x 10 Unexpanded 20 Expanded Kits are complete with spring stand offs silicone ZDV5FC Flex Connector 5 Diameter...

Страница 75: ...celain Reflective Liner Optional Fan Kit Blower Z46FK Fan Kit w Variable Speed Wall Mount Control Temperature Sensing 26IDV P260 Blower Motor Replacement Safety Screens ZCV48CSS Safety Screen Replacem...

Страница 76: ...for Door Frame 1000 085 Control Variable Speed KBWC 13BV FP15GC Stainless Steel Gas Connector Kingsman Fireplace Venting Z58DFA M G Duravent Adapter 5 x 8 Z58VT Vertical Vent Termination Z58HT Horizon...

Страница 77: ...other than in a normal residential environment c damages caused by any unauthorized alteration or repair of the unit affecting its stability or performance d damages caused by improper matching or app...

Отзывы: