background image

MCVP42   

 

 

 

 Parts List 

Fireplace Part Numbers 

MCVP42N 

(Millivolt) Fireplace Decorative rated, 
NG, Tempered Glass, Safety Screens 

MCVP42NH 

(Millivolt) Fireplace Heater rated, NG, 
Ceramic Glass, Safety Screens 

MCVP42NE 

(IPI) Fireplace Decorative Rated NG, 
Tempered Glass, Safety Screens 

MCVP42NHE 

(IPI) Fireplace Heater Rated NG, 
Ceramic Glass, Safety Screens 

MCVP42LP 

(Millivolt) Fireplace Decorative Rated 
LP, Tempered Glass, Safety Screens 

MCVP42LPH 

(Millivolt) Fireplace Heater Rated LP, 
Ceramic Glass, Safety Screens 

MCVP42LPE 

(IPI) Fireplace Decorative Rated LP, 
Tempered Glass, Safety Screens 

MCVP42LPHE 

(IPI) Fireplace Heater Rated LP, 
Ceramic Glass, Safety Screens 

MCVP42 Options  

M42LOG3 

Driftwood Log Set- 6 Pcs  
(Use with GT only) 

M42LOG4 

Oak Log Set- 8 Pcs  
(Use with LG only) 

VLBIT4 

Log Bits - Large Four Piece Kit 

VLBIT6 

Log Bits - Small Six Piece Kit 

MP42GT 

Glass Tray- Requires 10LBS Glass 

M42LG 

Log Grate 

42MVB-258

 

Pilot Shield - for MP42GT & M42LG

 

ZG5C 

Decorative Ember Glass 

–Bronze 5LB

 

RBCB1 

Cannonballs- Assorted size and colors 

ULK3 

Universal Light Kit 

3927ZDV-P779-1 

Bulb 10W 12V 64418 or [Sylvania 
58691] (light bulbs NOT covered under 
Warranty.) 

5143-P77912    

Lamp Assembly 58mm (light bulbs 
NOT covered under Warranty.) 

3927ZDV-P601 

Transformer MET60-1 

MCVP42 OPTIONS 

– MQ DEALER ONLY - 

MQ42LOG1 

Driftwood Log Set- 8pcs 
(Use with GT or LG) 

MQ42LOG2 

Oak Log Set- 7pcs 
(Use with GT or LG) 

MQSTONE 

Decorative Stones 

MQROCK2 

Rock Set Natural 

MQROCK3 

Rock Set Multi-Color 

MQEMBER 

Glowing Embers 

MQG5W 

Decorative Glass 1/2” White 5LB 

MQG5A 

Decorative Ember Glass Cobalt Blue 
5LB 

MQG5B 

Decorative Ember Glass 

– Black 5LB 

MQG5ZG 

Decorative Glass- Zircon Glacier Ice 
5LB 

Refractory Liners 

MP42RLT 

Refractory Liner Traditional  
(Use with LG only) 

MP42PL 

Porcelain Reflective Liner 
(Use with GT or LG) 

Child Safety Screens 

MP42CSSL 

Child Safety Screen (Large) 

MP42CSSS 

Child Safety Screen (Small) 

Door Glass 

42HB-310 

Tempered Glass-for Decorative 
Units 

42HB-311 

Ceramic Glass-for Heater Rated 
Units 

42MCVP-315T 

Tempered Glass-for Decorative 
Units 

42MCVP-315C 

Ceramic Glass-for Heater Rated 
Units 

46ZRB-123A 

Door Latch Assembly 

Replacement Burner Assembly / Burner 

42MP-200A 

Fireplace Burner  

42MP-BLPSI 

Burner Assembly- Propane c/w Valve 
System (MCVP42LP) 

42MP -BLPSIH 

Burner Assembly- Propane c/w Valve 
System (MCVP42LPH) 

42MP -BNGSI 

Burner Assembly- Natural Gas c/w Valve 
System (MCVP42N) 

42MP-BNGSIH 

Burner Assembly- Natural Gas c/w Valve 
System (MCVP42NH) 

42MP-BLPSIE 

Burner Assembly- Propane c/w Valve 
System (MCVP42LPE) 

42MP-BLPSIHE 

Burner Assembly- Propane c/w Valve 
System (MCVP42LPHE) 

42MP-BNGSIE 

Burner Assembly- Natural Gas c/w Valve 
System (MCVP42NE) 

42MP-BNGSIHE 

Burner Assembly- Natural Gas c/w Valve 
System (MCVP42NHE) 

Conversion Kit 

42MP-CKLP 

LP Conversion Kit for MCVP42 Millivolt 

42MP-CKLPH 

LP Conversion Kit for MCVP42H Millivolt 

42MP-CKNG 

NG Conversion Kit for MCVP42 Millivolt

 

42MP-CKNGH 

NG Conversion Kit for MCVP42H Millivolt 

42MP-CKLPI 

LP Conversion Kit for MCVP42 IPI

 

42MP-CKLPHI 

LP Conversion Kit for MCVP42H IPI 

42MP-CKNGI 

NG Conversion Kit for MCVP42 IPI

 

42MP-CKNGHI 

NG Conversion Kit for MCVP42H IPI 

Baffle Conversion Kit 

42MP-BCKNG 

NG Heater / upgrade Kit for MCVP42N / NE 
to MCVP42NH /NHE 

42MP-BCKLP 

LP Heater / upgrade Kit for MCVP42LP / 
LPE to MCVP42LPH /LPHE 

Accessories 

Z1MT 

Thermostat Millivolt Wall Mount 

Z80PT

 

Thermostat Programmable Digital 
Millivolt Wall Mount (1F80-40) 

Valve System Parts / Millivolt 

1000-P136WR 

Generator / Thermopile 

1001-P069SI 

Electrode Sparker 915.069 TC SIT 

1001-P216SI 

Thermocouple 290.216 TC SIT 

1001-P165SI

 

Orifice Pilot NG 977.165 TC SIT

 

1001-P167SI

 

Orifice Pilot LP 977.167 TC SIT

 

1001-P280SI

 

Tubing 24”

 

1001-P633SI

 

Valve Nova LP Hi/Lo 0820651

 

1001-P634SI

 

Valve Nova NG Hi/Lo 0820652

 

1001-P713SI

 

Pilot Burner LP 199.713 TC SIT

 

1001-P714SI

 

Pilot Burner NG 199.714 TC SIT

 

 
 

63

All manuals and user guides at all-guides.com

Содержание MCVP42LP

Страница 1: ...peg Manitoba Canada R2R 2V3 Ph 204 632 1962 Printed in Canada May 5 2015 Part 42MCVP MAN14 For Propane Horizontal installations the venting must be an additional one foot above the minimum vertical ri...

Страница 2: ...or use with GT Glass Tray 24 MQ42LOG1 8 Piece Driftwood Log Set For use with M42LG Log Grate 25 MQ42LOG2 7 Piece Oak Log Set For use with GT Glass Tray 26 MQ42LOG2 7 Piece Oak Log Set For use with M42...

Страница 3: ...emote ON OFF Variable HI LO and Fan 52 Electronic Ignition Lighting Instructions 53 VENTING Vent Termination 54 General Vent Installation 55 Installation of Side Wall Venting 55 Venting Routes And Com...

Страница 4: ...and other at risk individuals out of the room and away from hot surfaces Do not leave the fireplace remote control where it is accessible to children Termination Cap Safety All Units WARNING WHEN THE...

Страница 5: ...repair should be done by a qualified service person The appliance should be inspected before use and at least annually by a professional service person More frequent cleaning may be required due to ex...

Страница 6: ...oom s The carbon monoxide detector shall comply with NFPA 720 B A carbon monoxide detector shall be located in the room that houses the appliance or equipment and shall Be powered by the same electric...

Страница 7: ...tile and the adhesives used to adhere this product to the walls can react with heat and cause odours It is recommended that you burn your gas fireplace or stove for a minimum of four hours at a time w...

Страница 8: ...imum 20 gauge Minimum of 1 2 DUROCK cement board this non combustible panel is ULC listed as a wall shield floor protector and fasten to the entire perimeter framing Use fiberglass mesh tape for all j...

Страница 9: ...al Code in Canada An appliance must be grounded to the steel chassis of the home with 8 ga copper wire using a serrated or star washer to penetrate paint or protective coating to insure grounding Use...

Страница 10: ...e to be covered with Non Combustibles e g Concrete Board for Flat Wall appearance Qty 4 Nailing Tabs are located on flue side of fireplace Nailing Tab Framing Stud Drywall Non Combustible Material eg...

Страница 11: ...e These stand offs are provided as indicators to illustrate the boundaries for framing Therefore no framing material is permitted to extend beyond these stand offs Vertical Venting in Cold Climates In...

Страница 12: ...ur Appliance See Mantel Leg Clearances Instruction for the proper placement of fireplace MCVP42 Fireplace Dimensions ISLAND ALL UNITS MAY BE VENTED VERTICALLY PENINSULA 12 All manuals and user guides...

Страница 13: ...ove the minimum vertical rise off the flue before going horizontal Framed fireplace opening 55 MIN for NG 67 MIN for LP Plus Rise of Per Foot 55 MIN for NG 67 MIN for LP Plus Rise of Per Foot Vent Fra...

Страница 14: ...UST BE NON COMBUSTIBLE It is also recommended to attach Non combustible facing to framing Combustibles i e Drywall may be installed flush with top of Fireplace Side facing to be installed to standoffs...

Страница 15: ...to finish face of wall NOTE Drywall will be flush with fireplace face Step 3 A brick tile or other non combustible border may be applied over fireplace face to conceal border Nailing Tab Drywall Firep...

Страница 16: ...k your local codes and regulations to determine whether your mantel is combustible or Non Combustible The advantage of a Non Combustible Mantel is that it can begin at the top of the fireplace opening...

Страница 17: ...of the appliance must be used Carpet may extend 1 inch above the floor of the appliance Minimum Ceiling Height from bottom of fireplace 61 Top from Stand offs 0 Top of 90 Bend in minimum Enclosure of...

Страница 18: ...Hook lower clip onto glass door frame Press down and push upper clip under top glass door frame Screens shown locked in place Clips First install smaller end screen Then install side screens Clips To...

Страница 19: ...to install Porcelain Liners WARNING Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage...

Страница 20: ...d Units or Deflectors Decorative Units Refer to Baffle Removal Deflector Removal sections of manual 2 Orient tabs in upper firebox as shown 3 Insert Liner into Firebox 4 Bend Tabs down over Brick Line...

Страница 21: ...nd screw first Replace 4 remaining screws ZCV42MCVP Deflector Removal Decorative Units To Remove Deflectors Remove 2 DT Screws holding each Deflector in place To Replace Deflectors Replace 2 DT Screws...

Страница 22: ...red The following items can be used with the Glass Tray ULK3 Light Kit MQLOG1 MQLOG2 M42LOG3 RBCB1 Cannonballs VLBIT4 or VLBIT6 Decorative Glass MQSTONE MQROCK2 or MQROCK3 MQEMBER Refer to appropriate...

Страница 23: ...ay with screws To Remove 1 Remove screws holding Grate Assemblies in place 2 Remove screws holding Grate Plate in place 3 Remove from firebox Contents of Kit 1 2 Log Grates 2 2 Large Bags 3 4 Lava Roc...

Страница 24: ...6 8 7 WARNING Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage or personal injury 1...

Страница 25: ...parts specifically approved with this appliance may result in property damage or personal injury 2 5 6 8 1 3 4 7 PILOT Place 350 Embers from M42LG in Burner Tray Place Insulation Wool from M42LG in B...

Страница 26: ...ailure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage or personal injury 1 5 4 3 2 1 6 7 P...

Страница 27: ...s specifically approved with this appliance may result in property damage or personal injury 1 3 1 4 2 7 5 6 PILOT Place 350 Embers from M42LG in Burner Tray Place Insulation Wool from M42LG in Burner...

Страница 28: ...5 6 WARNING Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage or personal injury 1 5...

Страница 29: ...specifically approved with this appliance may result in property damage or personal injury 1 8 1 2 3 4 5 6 7 8 PILOT Place 350 Embers from M42LG in Burner Tray Place Insulation Wool from M42LG in Burn...

Страница 30: ...first NOTE When using a remote control the 51 UHS Box must be used Batteries for Remote Receiver can be changed by lifting 51 UHS up through opening 51 UHS can be inserted removed from beneath firepl...

Страница 31: ...or plug black and red transformer wires together if 120V receptacle will be switch controlled REFER TO COMPONENT LOCATIONS SECTION OF MANUAL FOR TRANSFORMER PLACEMENT Please follow the current ANSI N...

Страница 32: ...r your protection against shock hazard and should be plugged directly into a properly grounded three prong receptacle Label all wires prior to disconnection when servicing controls Wiring errors can c...

Страница 33: ...placed directly on Burner and on Glass Tray MQ Ember can be placed directly on Burner Only Lava Rock Supplied with Base Unit CANNOT be placed on Burner Place Lava Rock in channel in front of Glass Tra...

Страница 34: ...on Burner Tube and Burner Tray 15lbs on Glass Tray 25lbs Max total MQG5W Decorative Glass 1 2 White MQG5A Decorative Ember Glass Cobalt Blue MQG5B Decorative Ember Glass Black MQG5ZG Decorative Glass...

Страница 35: ...lations If sooting occurs change position of or remove affected objects MQEMBER To be placed directly on Burner and Burner Ports Place these glowing ember chunks randomly May be used with or without o...

Страница 36: ...an angle of between 15 and 30 degrees 3 Swing door up and pull top latches over door lip at each corner 4 Replace Access Cover below Glass Door 30 15 WARNING Wait until unit is COMPLETELY cool before...

Страница 37: ...val of Large Glass Doors 1 Remove the door by unlatching the 2 top latches Simply place 2 fingers in the grooves and pull and lift upward slightly 2 Once the top of the door is unlatched pull it outwa...

Страница 38: ...that system at test pressures in excess of 1 2 PSIG 3 5 KPa 9 The appliance must be isolated from the gas supply piping system by closing its individual shutoff valve during any pressure testing of th...

Страница 39: ...ide of the main burner If a flame has appeared then continue to depress the control knob for 20 seconds If the flame did not appear then continue to depress the red igniter button every 5 seconds unti...

Страница 40: ...millivolt meter Take reading at generator terminals of gas valve Should read 325 millivolts minimum while holding valve knob depressed in pilot position and wall switch off Replace faulty generator i...

Страница 41: ...caution when working within the area ALL WORK SHOULD BE PERFORMED BY A QUALIFIED AND CERTIFIED TECHNICIAN Monthly Flame Inspection It is recommended to turn on the unit at least once a month and insp...

Страница 42: ...onversion and Hi Lo valve regulator by following instructions supplied with the Conversion Kit Refer to Gas Specifications Chart for inlet pressures and input ratings Clock meter to verify input rate...

Страница 43: ...of the injector near the top LPG injectors have a groove machined around their circumference near the top while NG injectors do not have a groove fig 4 Refer to the Appliance Manufacturer s instructi...

Страница 44: ...Gas Conversion for Modulator PART C WARNING WARNING 44 All manuals and user guides at all guides com...

Страница 45: ...ner Removal instructions above to remove burner Remove fourteen 14 screws around edge of Burner Pan Carefully work the burner pan loose lift the assembly upward to remove it from the firebox cavity In...

Страница 46: ...odule Fan Control Module UHS Box Cover Backup Battery Pack Modulating Servo Motor Is an add on valve component that permits HI LO functionality to be controlled by the remote Contrary to this feature...

Страница 47: ...ey The LCD display on the Transmitter will change to show that the room thermostat is ON and the set temperature is now displayed To adjust the set temperature press the Up or Down Arrow Keys until th...

Страница 48: ...e Flame Sensor 35 Length 5 1002 P302si IPI Ignition Board 6 1002 P850si AC Wall Adapter 7 1002 P12BH Battery Pack 8 1002 P912si Wiring Harness 9 1001 P166si Orifice Pilot NG 62 1001 P168si Orifice Pil...

Страница 49: ...Configuration 1 Basic Manual HI LO and Manual ON OFF Capabilities 49 All manuals and user guides at all guides com...

Страница 50: ...nal For units with remote HI LO capabilities a modulating servo is required to be installed on the valve The connectors to this servo must be connected to the Remote Harness as shown in the figure bel...

Страница 51: ...d by the AC Adapter This is advantageous if you do not want to use batteries Simply connect the AC Adapter into the Remote Control Wiring Harness as per the diagrams below IPI System EGTM Receiver Mod...

Страница 52: ...Configuration 3 Remote ON OFF Variable HI LO Lights and Fan NOTE FAN IS NOT AVAILABLE ON 42MCVP UNITS ULK LIGHT KIT 52 All manuals and user guides at all guides com...

Страница 53: ...NSTRUCTIONS 1 Stop Read the above safety information on this label 2 Remove batteries from receiver and or Battery Backup Pack 3 Turn off all electric power to the fireplace 4 This fireplace is equipp...

Страница 54: ...paved sidewalk or a paved driveway located on public property 7 feet 2 1m minimum 3 M Clearance above highest point of exit on roof 18 inches 45cm N Clearance to perpendicular wall 24 inches 60 cm Rec...

Страница 55: ...f vent see the Framing Your Gas Fireplace section Cut a hole through the wall allowing for a 12 x 12 inside diameter in combustible walls for wall thimble or a 9 diameter hole in a non combustible wal...

Страница 56: ...bends required 2 Having determined the vertical distance determine the maxi mum horizontal section allowed 3 Vent table has been established for 90 horizontal vertical runs With use of flex pipe dist...

Страница 57: ...n the future Wall Thimble mount plate will be smaller than Termination Plate as a running change has been implemented Wall Thimble may need to be trimmed on outside mount plate to be completely hidden...

Страница 58: ...all Thimble 15 3 4 13 5 16 1 3 16 Termination New Wall Thimble Old Termination 13 3 4 13 5 16 3 16 New Wall Thimble New Termination Wall Thimble 13 3 4 New Termination Old Wall Thimble Termination Ter...

Страница 59: ...le to your roof slope over the vent Place the edge of the flashing plate that will be on the higher part of the roof slope under the shingles Both the sides and the lower edge lay on top of the shingl...

Страница 60: ...horizontal venting Straight through roof support configuration b Flex bend configuration c Termination mounting 43ft Z58VT Restrictor Remove for Runs Under 15 Feet 60 All manuals and user guides at a...

Страница 61: ...permitted NOTE MODELS EQUIPPPED WITH INTERMITTENT PILOT IGNITION Downward vertical vent runs are permitted however Cold Climate Switch Standing Pilot Mode must not be used Refer to your appliance manu...

Страница 62: ...8 Flex Kit 5 8 Dia x 4 Unexpanded 8 Expanded Z58FK20 Flex Kit 5 8 Dia x 10 Unexpanded 20 Expanded Kits are complete with spring stand offs silicone ZDV5FC Flex Connector 5 Diameter ZDV8FC Flex Connect...

Страница 63: ...e MP42CSSS Child Safety Screen Small Door Glass 42HB 310 Tempered Glass for Decorative Units 42HB 311 Ceramic Glass for Heater Rated Units 42MCVP 315T Tempered Glass for Decorative Units 42MCVP 315C C...

Страница 64: ...Sealant 840099 1000 214 Piezo Igniter 1244 17 MARK 21 1000 215 Pal Nut 18MMXI 5MM BLK 1364 03 1000 218 Switch Ivory 1451 001 1000 227 Cover Ivory 86001 001 1000 255 Orifice Brass State Size 3600 B139...

Страница 65: ...residential environment c damages caused by any unauthorized alteration or repair of the unit affecting its stability or performance d damages caused by improper matching or application of the unit or...

Отзывы: