Warning!
The  installation  of  this  conversion  kit  must  only  be  undertaken  by  a  qualified  and 
certified gas appliance installer.

SIT Group

Warning!

This  conversion  kit  must  only  be  applied  as  part  of  a  conversion  kit  supplied  by  the 
aPPlianCE ManUFaCTUrEr for the specific appliance, and type of gas, being converted.

inSTallEr noTiCE. These instructions must be left with appliance.

w w w . s i t g r o u p . i t

1

2

3

4

5

6

7

8

Shut-off the gas supply to the appliance.

Allow the pilot burner to cool to room temperature.

Warning:  Touching  a  hot  pilot  burner 

can result in injury.

The pilot hood is held in place by spring.

First remove the spring, then remove the hood by 

pulling it up from the pilot bracket (fig. 1).

Insert  a  5/32"  or  4  mm  Allen  wrench  into  the 

hexagonal  key-way  of  the  injector  (fig.  2),  and 

rotate  it  counter-clockwise  until  it  is  free  of  the 

injector journal.

Verify  that  the  new  injector  is  proper  for  the 

application.  The  injector  size  is  stamped  on  the 

side of the injector near the top. LPG injectors have 

a  groove  machined  around  their  circumference 

near  the  top,  while  NG  injectors  do  not  have  a 

groove (fig. 4).

Refer  to  the  Appliance  Manufacturer’s  instruction 

sheet for the proper injector size.

Insert the Allen wrench into the end of the injector. 

Then,  insert  the  injector  into  injector  journal,  and 

rotate the injector clockwise until a torque of 9 lbf 

in (1.0 Nm) is achieved.

First replace the pilot hood by aligning the tab on 

the base of the hood with the slot in the side of the 

pilot  journal,  and  push  the  hood  down,  onto  the 

pilot bracket (fig. 3). The hood must sit squarely on 

the bracket for proper operation. 

Then  replace  the  spring  by  pushing  it  on  his  seat 

(fig.3). 

Check  to  insure  that  the  hood  is  properly  seated 

onto  the  pilot  bracket  and  that  the  spring  is 

properly inserted onto his seat.

Restore the gas supply to the appliance, and ignite 

the pilot burner. 

Verify proper ignition and operation.

Instructions  for  converting  SIT  190  series  pilot  burner  injector  from  NG  to  LPG  and  from  LPG  to  NG  only.                 
This information should be considered as supplemental to the Appliance Manufacturer's Instructions.

fig. 1

fig. 2

fig. 3

LPG

NG

fig. 4

Injectors

DRAFT    A00 

43

All manuals and user guides at all-guides.com

Содержание MCVP42LP

Страница 1: ...peg Manitoba Canada R2R 2V3 Ph 204 632 1962 Printed in Canada May 5 2015 Part 42MCVP MAN14 For Propane Horizontal installations the venting must be an additional one foot above the minimum vertical ri...

Страница 2: ...or use with GT Glass Tray 24 MQ42LOG1 8 Piece Driftwood Log Set For use with M42LG Log Grate 25 MQ42LOG2 7 Piece Oak Log Set For use with GT Glass Tray 26 MQ42LOG2 7 Piece Oak Log Set For use with M42...

Страница 3: ...emote ON OFF Variable HI LO and Fan 52 Electronic Ignition Lighting Instructions 53 VENTING Vent Termination 54 General Vent Installation 55 Installation of Side Wall Venting 55 Venting Routes And Com...

Страница 4: ...and other at risk individuals out of the room and away from hot surfaces Do not leave the fireplace remote control where it is accessible to children Termination Cap Safety All Units WARNING WHEN THE...

Страница 5: ...repair should be done by a qualified service person The appliance should be inspected before use and at least annually by a professional service person More frequent cleaning may be required due to ex...

Страница 6: ...oom s The carbon monoxide detector shall comply with NFPA 720 B A carbon monoxide detector shall be located in the room that houses the appliance or equipment and shall Be powered by the same electric...

Страница 7: ...tile and the adhesives used to adhere this product to the walls can react with heat and cause odours It is recommended that you burn your gas fireplace or stove for a minimum of four hours at a time w...

Страница 8: ...imum 20 gauge Minimum of 1 2 DUROCK cement board this non combustible panel is ULC listed as a wall shield floor protector and fasten to the entire perimeter framing Use fiberglass mesh tape for all j...

Страница 9: ...al Code in Canada An appliance must be grounded to the steel chassis of the home with 8 ga copper wire using a serrated or star washer to penetrate paint or protective coating to insure grounding Use...

Страница 10: ...e to be covered with Non Combustibles e g Concrete Board for Flat Wall appearance Qty 4 Nailing Tabs are located on flue side of fireplace Nailing Tab Framing Stud Drywall Non Combustible Material eg...

Страница 11: ...e These stand offs are provided as indicators to illustrate the boundaries for framing Therefore no framing material is permitted to extend beyond these stand offs Vertical Venting in Cold Climates In...

Страница 12: ...ur Appliance See Mantel Leg Clearances Instruction for the proper placement of fireplace MCVP42 Fireplace Dimensions ISLAND ALL UNITS MAY BE VENTED VERTICALLY PENINSULA 12 All manuals and user guides...

Страница 13: ...ove the minimum vertical rise off the flue before going horizontal Framed fireplace opening 55 MIN for NG 67 MIN for LP Plus Rise of Per Foot 55 MIN for NG 67 MIN for LP Plus Rise of Per Foot Vent Fra...

Страница 14: ...UST BE NON COMBUSTIBLE It is also recommended to attach Non combustible facing to framing Combustibles i e Drywall may be installed flush with top of Fireplace Side facing to be installed to standoffs...

Страница 15: ...to finish face of wall NOTE Drywall will be flush with fireplace face Step 3 A brick tile or other non combustible border may be applied over fireplace face to conceal border Nailing Tab Drywall Firep...

Страница 16: ...k your local codes and regulations to determine whether your mantel is combustible or Non Combustible The advantage of a Non Combustible Mantel is that it can begin at the top of the fireplace opening...

Страница 17: ...of the appliance must be used Carpet may extend 1 inch above the floor of the appliance Minimum Ceiling Height from bottom of fireplace 61 Top from Stand offs 0 Top of 90 Bend in minimum Enclosure of...

Страница 18: ...Hook lower clip onto glass door frame Press down and push upper clip under top glass door frame Screens shown locked in place Clips First install smaller end screen Then install side screens Clips To...

Страница 19: ...to install Porcelain Liners WARNING Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage...

Страница 20: ...d Units or Deflectors Decorative Units Refer to Baffle Removal Deflector Removal sections of manual 2 Orient tabs in upper firebox as shown 3 Insert Liner into Firebox 4 Bend Tabs down over Brick Line...

Страница 21: ...nd screw first Replace 4 remaining screws ZCV42MCVP Deflector Removal Decorative Units To Remove Deflectors Remove 2 DT Screws holding each Deflector in place To Replace Deflectors Replace 2 DT Screws...

Страница 22: ...red The following items can be used with the Glass Tray ULK3 Light Kit MQLOG1 MQLOG2 M42LOG3 RBCB1 Cannonballs VLBIT4 or VLBIT6 Decorative Glass MQSTONE MQROCK2 or MQROCK3 MQEMBER Refer to appropriate...

Страница 23: ...ay with screws To Remove 1 Remove screws holding Grate Assemblies in place 2 Remove screws holding Grate Plate in place 3 Remove from firebox Contents of Kit 1 2 Log Grates 2 2 Large Bags 3 4 Lava Roc...

Страница 24: ...6 8 7 WARNING Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage or personal injury 1...

Страница 25: ...parts specifically approved with this appliance may result in property damage or personal injury 2 5 6 8 1 3 4 7 PILOT Place 350 Embers from M42LG in Burner Tray Place Insulation Wool from M42LG in B...

Страница 26: ...ailure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage or personal injury 1 5 4 3 2 1 6 7 P...

Страница 27: ...s specifically approved with this appliance may result in property damage or personal injury 1 3 1 4 2 7 5 6 PILOT Place 350 Embers from M42LG in Burner Tray Place Insulation Wool from M42LG in Burner...

Страница 28: ...5 6 WARNING Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage or personal injury 1 5...

Страница 29: ...specifically approved with this appliance may result in property damage or personal injury 1 8 1 2 3 4 5 6 7 8 PILOT Place 350 Embers from M42LG in Burner Tray Place Insulation Wool from M42LG in Burn...

Страница 30: ...first NOTE When using a remote control the 51 UHS Box must be used Batteries for Remote Receiver can be changed by lifting 51 UHS up through opening 51 UHS can be inserted removed from beneath firepl...

Страница 31: ...or plug black and red transformer wires together if 120V receptacle will be switch controlled REFER TO COMPONENT LOCATIONS SECTION OF MANUAL FOR TRANSFORMER PLACEMENT Please follow the current ANSI N...

Страница 32: ...r your protection against shock hazard and should be plugged directly into a properly grounded three prong receptacle Label all wires prior to disconnection when servicing controls Wiring errors can c...

Страница 33: ...placed directly on Burner and on Glass Tray MQ Ember can be placed directly on Burner Only Lava Rock Supplied with Base Unit CANNOT be placed on Burner Place Lava Rock in channel in front of Glass Tra...

Страница 34: ...on Burner Tube and Burner Tray 15lbs on Glass Tray 25lbs Max total MQG5W Decorative Glass 1 2 White MQG5A Decorative Ember Glass Cobalt Blue MQG5B Decorative Ember Glass Black MQG5ZG Decorative Glass...

Страница 35: ...lations If sooting occurs change position of or remove affected objects MQEMBER To be placed directly on Burner and Burner Ports Place these glowing ember chunks randomly May be used with or without o...

Страница 36: ...an angle of between 15 and 30 degrees 3 Swing door up and pull top latches over door lip at each corner 4 Replace Access Cover below Glass Door 30 15 WARNING Wait until unit is COMPLETELY cool before...

Страница 37: ...val of Large Glass Doors 1 Remove the door by unlatching the 2 top latches Simply place 2 fingers in the grooves and pull and lift upward slightly 2 Once the top of the door is unlatched pull it outwa...

Страница 38: ...that system at test pressures in excess of 1 2 PSIG 3 5 KPa 9 The appliance must be isolated from the gas supply piping system by closing its individual shutoff valve during any pressure testing of th...

Страница 39: ...ide of the main burner If a flame has appeared then continue to depress the control knob for 20 seconds If the flame did not appear then continue to depress the red igniter button every 5 seconds unti...

Страница 40: ...millivolt meter Take reading at generator terminals of gas valve Should read 325 millivolts minimum while holding valve knob depressed in pilot position and wall switch off Replace faulty generator i...

Страница 41: ...caution when working within the area ALL WORK SHOULD BE PERFORMED BY A QUALIFIED AND CERTIFIED TECHNICIAN Monthly Flame Inspection It is recommended to turn on the unit at least once a month and insp...

Страница 42: ...onversion and Hi Lo valve regulator by following instructions supplied with the Conversion Kit Refer to Gas Specifications Chart for inlet pressures and input ratings Clock meter to verify input rate...

Страница 43: ...of the injector near the top LPG injectors have a groove machined around their circumference near the top while NG injectors do not have a groove fig 4 Refer to the Appliance Manufacturer s instructi...

Страница 44: ...Gas Conversion for Modulator PART C WARNING WARNING 44 All manuals and user guides at all guides com...

Страница 45: ...ner Removal instructions above to remove burner Remove fourteen 14 screws around edge of Burner Pan Carefully work the burner pan loose lift the assembly upward to remove it from the firebox cavity In...

Страница 46: ...odule Fan Control Module UHS Box Cover Backup Battery Pack Modulating Servo Motor Is an add on valve component that permits HI LO functionality to be controlled by the remote Contrary to this feature...

Страница 47: ...ey The LCD display on the Transmitter will change to show that the room thermostat is ON and the set temperature is now displayed To adjust the set temperature press the Up or Down Arrow Keys until th...

Страница 48: ...e Flame Sensor 35 Length 5 1002 P302si IPI Ignition Board 6 1002 P850si AC Wall Adapter 7 1002 P12BH Battery Pack 8 1002 P912si Wiring Harness 9 1001 P166si Orifice Pilot NG 62 1001 P168si Orifice Pil...

Страница 49: ...Configuration 1 Basic Manual HI LO and Manual ON OFF Capabilities 49 All manuals and user guides at all guides com...

Страница 50: ...nal For units with remote HI LO capabilities a modulating servo is required to be installed on the valve The connectors to this servo must be connected to the Remote Harness as shown in the figure bel...

Страница 51: ...d by the AC Adapter This is advantageous if you do not want to use batteries Simply connect the AC Adapter into the Remote Control Wiring Harness as per the diagrams below IPI System EGTM Receiver Mod...

Страница 52: ...Configuration 3 Remote ON OFF Variable HI LO Lights and Fan NOTE FAN IS NOT AVAILABLE ON 42MCVP UNITS ULK LIGHT KIT 52 All manuals and user guides at all guides com...

Страница 53: ...NSTRUCTIONS 1 Stop Read the above safety information on this label 2 Remove batteries from receiver and or Battery Backup Pack 3 Turn off all electric power to the fireplace 4 This fireplace is equipp...

Страница 54: ...paved sidewalk or a paved driveway located on public property 7 feet 2 1m minimum 3 M Clearance above highest point of exit on roof 18 inches 45cm N Clearance to perpendicular wall 24 inches 60 cm Rec...

Страница 55: ...f vent see the Framing Your Gas Fireplace section Cut a hole through the wall allowing for a 12 x 12 inside diameter in combustible walls for wall thimble or a 9 diameter hole in a non combustible wal...

Страница 56: ...bends required 2 Having determined the vertical distance determine the maxi mum horizontal section allowed 3 Vent table has been established for 90 horizontal vertical runs With use of flex pipe dist...

Страница 57: ...n the future Wall Thimble mount plate will be smaller than Termination Plate as a running change has been implemented Wall Thimble may need to be trimmed on outside mount plate to be completely hidden...

Страница 58: ...all Thimble 15 3 4 13 5 16 1 3 16 Termination New Wall Thimble Old Termination 13 3 4 13 5 16 3 16 New Wall Thimble New Termination Wall Thimble 13 3 4 New Termination Old Wall Thimble Termination Ter...

Страница 59: ...le to your roof slope over the vent Place the edge of the flashing plate that will be on the higher part of the roof slope under the shingles Both the sides and the lower edge lay on top of the shingl...

Страница 60: ...horizontal venting Straight through roof support configuration b Flex bend configuration c Termination mounting 43ft Z58VT Restrictor Remove for Runs Under 15 Feet 60 All manuals and user guides at a...

Страница 61: ...permitted NOTE MODELS EQUIPPPED WITH INTERMITTENT PILOT IGNITION Downward vertical vent runs are permitted however Cold Climate Switch Standing Pilot Mode must not be used Refer to your appliance manu...

Страница 62: ...8 Flex Kit 5 8 Dia x 4 Unexpanded 8 Expanded Z58FK20 Flex Kit 5 8 Dia x 10 Unexpanded 20 Expanded Kits are complete with spring stand offs silicone ZDV5FC Flex Connector 5 Diameter ZDV8FC Flex Connect...

Страница 63: ...e MP42CSSS Child Safety Screen Small Door Glass 42HB 310 Tempered Glass for Decorative Units 42HB 311 Ceramic Glass for Heater Rated Units 42MCVP 315T Tempered Glass for Decorative Units 42MCVP 315C C...

Страница 64: ...Sealant 840099 1000 214 Piezo Igniter 1244 17 MARK 21 1000 215 Pal Nut 18MMXI 5MM BLK 1364 03 1000 218 Switch Ivory 1451 001 1000 227 Cover Ivory 86001 001 1000 255 Orifice Brass State Size 3600 B139...

Страница 65: ...residential environment c damages caused by any unauthorized alteration or repair of the unit affecting its stability or performance d damages caused by improper matching or application of the unit or...

Отзывы: