background image

 

 

Parts List 

Serenity Zero Clearance Direct Vent Gas Fireplace 
– 19” Wide 

 
Listed for USA/Canada, Tube Burner, Ceramic Glass, SIT 
Nova Valve with Hi/Lo Adjustment, Wall Switch, 4”/7” Top 
Flue, Framing 19-5/8W x 33H x 15D 
 

MQZDV1917N 

Fireplace Heater; Milli Volt (as above) 
Natural Gas; 17,000 BTU 
Approved for bedroom & mobile home. 

MQZDV1917LP 

Fireplace Heater; Milli Volt (as above) 
Propane; 17,000 BTU 
Approved for bedroom & mobile home. 

MQZDV1917NE 

Fireplace Heater; IPI Valve (as above) 
Natural Gas; 17,000 BTU 
Approved for bedroom & mobile home. 

MQZDV1917LPE  Fireplace Heater; IPI Valve (as above) 

Propane; 17,000 BTU 
Approved for bedroom & mobile home. 

 

 

Finishing Surround 

Straight or Arch Surround (Required for Each Unit) 

MQ19SSBL 

Surround – Straight – Black 

MQ19SSPW 

Surround – Straight – Pewter 

MQ19SSCV 

Surround – Straight – Vintage Copper 
Vein 

MQ19SABL 

Surround – Arch – Black 

MQ19SAPW 

Surround – Arch – Pewter 

MQ19SACV 

Surround – Arch - Vintage Copper Vein 

 

 

Grill and Arch Door Kit 

Diamond or Leaf Patter (Required for Each Unit) 

MQ19GDBL 

Grill and Arch Door Kit – Diamond 
Pattern – Black 

MQ19GDPW 

Grill and Arch Door Kit – Diamond 
Pattern – Pewter 

MQ19GDCV 

Grill and Arch Door Kit – Diamond 
Pattern – Vintage Copper Vein 

MQ19GLBL 

Grill and Arch Door Kit – Leaf Pattern – 
Black 

MQ19GLPW 

Grill and Arch Door Kit – Leaf Pattern – 
Pewter 

MQ19GLCV 

Grill and Arch Door Kit – Leaf Pattern – 
Vintage Copper Vein 

 

 

Log/Rock Sets 

(Required for Each Unit) 

MQLOGC19 

Cast Log Set – Split Oak 

 

 

Accessories 

MQ19FK 

Fan Kit w/ Variable Speed (Temperature 
Sensing) 

MQ19PL Porcelain 

Reflective Panel Liner 

MQ19RL Brick 

Liner 

Z1MT 

Thermostat Millivolt Wall Mount  

Z80PT 

Thermostat Programmable Digital Millivolt 

Millivolt Remotes 

GFRC Remote 

Control 

On/Off 

GTRC 

Remote Control - Thermostat 

GTMRCN 

Remote Control – Thermostat / 
Modulating – NG 

GTMRCP 

Remote Control – Thermostat / 
Modulating – LP 

GTFRCN 

Remote Control – Thermostat / 
Modulating / Fan – NG 

GTFRCP 

Remote Control – Thermostat / 
Modulating / Fan – NG 

IPI Remotes 

EGTRC   

Remote Control IPI - Thermostat  

EGTMRCN 

Remote Control IPI - 
Thermostat/Modulating - NG 

EGTMRCP 

Remote Control IPI - 
Thermostat/Modulating - LP 

 

 

Replacement Burner 

Assembly 

1917-BNGSI 

Burner Assembly; Natural Gas C/W 
Millivolt Valve System for MQZDV1917N 

1917-BLPSI 

Burner Assembly; Liquid Propane C/W 
Millivolt Valve System for 
MQZDV1917LP 

 

 

Valve System Parts 

1000-P136WR Thermopile 

GOAI-524 

1001-P069SI 

Electrode Sparker and Cable 915.069 
TC SIT 

1001-P216SI 

Thermocouple 290.216 TC SIT 

1001-P165SI 

Orifice Pilot NG 977.165 TC SIT 

1001-P167SI 

Orifice Pilot LP 977.167 TC SIT 

1001-P633SI 

Valve Nova LP Hi/Lo 0820651 

1001-P634Si 

Valve Nova NG Hi/Lo 0820652 

1001-P713SI 

Pilot Burner LP 199.713 TC SIT 

1001-P714SI 

Pilot Burner NG 199.714 TC SIT 

 

 

Conversion Kit 

1917-CKLP 

LP Conversion Kit for MQZDV1917LP       
Millivolt 

1917-CKNG 

NG Conversion Kit for MQZDV1917N        
Millivolt 

1917-CKLPI 

LP Conversion Kit for MQZDV1917LPE     
IPI 

1917-CKNGI 

NG Conversion Kit for MQZDV1917NE      
IPI 

Miscellaneous Parts 

1000-150GE 

#SILICONE GE RED IS806 #736 

1000-150MP 

#HI-TEMP MILL PAC SEALANT  

1000-214 #PIEZO-IGNITOR 

 

1000-215 

#PAL NUT (18MMXI.5MM)BLK  

1000-216 

#On/Off SWITCH  

47

Содержание Marquis Serenity MQZDV1917

Страница 1: ...al installations the venting must be a minimum of one foot vertical off the flue before going horizontal Installation Instructions Listed Certified for USA and Canada Model Number MQZDV1917 Stock s MQ...

Страница 2: ...Fan Installation 20 22 Baffle Replacement Guide 22 Gas Line Installation 23 Burner Removal Servicing Guide 24 Brick Liner Installation Guide 25 Porcelain Liner Installation Guide 26 Millivolt System L...

Страница 3: ...use odours It is recommended that you burn your gas fireplace or stove for a minimum of four hours at a time with the fan off after the curing of the paint has been completed These odours can last upw...

Страница 4: ...ILE HOMES Please follow the current ANSI NFPA 70 National Electrical Code in the USA and CAN CSA C22 1 Canadian National Electrical Code in Canada An appliance must be grounded to the steel chassis of...

Страница 5: ...g the appliance 15 Installation and repair should be done by a qualified service person The appliance should be inspected before use and at least annually by a professional service person More frequen...

Страница 6: ...PA 720 2005 Edition B A carbon monoxide detector shall be located in the room that houses the appliance or equipment and shall Be powered by the same electrical circuit as the appliance or equipment s...

Страница 7: ...ed Locating the Appliance The appliance can be located in the configura tions shown in Figure 2 Note that an Island installation with a top vent is possible as long as the horizontal portion of the ve...

Страница 8: ...on and greatly reduces carbon deposits and cleaning of glass Does not apply to Back Flue models Framing for your Gas Fireplace Stand off Locations This section will cover four different types of insta...

Страница 9: ...the unit Using the holes on the Front Tabs fasten the appliance to the Cabinet with the appropriate eight 8 screws Clearance to Combustibles Table 1 Clearance to combustibles for fireplace appliance B...

Страница 10: ...General Framing Installations Figure 5 General framing installation 10...

Страница 11: ...will be This formula is illustrated in Figure 5 Absolute Minimum Ceiling Height Min Ceiling Height Raised Height For cabinet installations It is necessary that the appliance be installed from the rea...

Страница 12: ...Figure 7 Cabinet installation Note that the unit MUST be installed from the back of the cabinet Figure 8 Dimensions for facing material cutout 12...

Страница 13: ...fireplace vent opening When using paint or lacquer to finish the mantel such paint or lacquer must be heat resistant 250 F 121 C to prevent discoloration Example If a mantel is desired to extend 4 1...

Страница 14: ...ith a sidewall i e a wall perpendicular to the face of the unit must adhere to the clearances imposed by the illustration shown in Figure 10 Figure 10 Sidewall clearance requirements Sidewall Clearanc...

Страница 15: ...n in the Dimensional Overview section NOTE Only one 2x4 stud header may be used in the frame Please refer to Figure 5 on page 10 or Figure 11 below To ensure the Front Surround covers the maximum area...

Страница 16: ...en the finished NOTE This Surround is capable of extending 5 8 away from the front of the unit Hence a wider range of facing materials can be accommodated without relocating the unit 4 To remove the F...

Страница 17: ...hown in Figure 14 3 Using the thumb screws washers and locking nuts provided fasten the Access Panel Grill to the Finishing Surround frame Observe the locations of the screw washer and nut Torque the...

Страница 18: ...efore recommended that initially the glass be cleaned two or three times with non abrasive common household glass cleansers and warm water After that the glass should be cleaned two or three times a s...

Страница 19: ...ion of the frame is IN FRONT of the Upper Mounting Tab and the lower portion is BEHIND the Lower Mounting Tab Figure 17 Arch Door installation 3 Swing the right side of the Arch Door into the unit Pos...

Страница 20: ...he fan directly simply connect the TERMINAL B wires to the thermal switch Thermodisc terminals 2 To have a unit mount variable control controlling the fan speed in conjunction with thermal switching s...

Страница 21: ...an kit power cord from the receptacle and the two 2 leads from the variable speed control thermal switch Remove the Burner Pan assembly Refer to the Burner Removal Servicing Guide section 2 Lift the f...

Страница 22: ...Please make note of their location before beginning the replacement procedure IMPORTANT Examine the condition of the mounting holes and screws It is required that these areas are sealed properly If t...

Страница 23: ...olution 8 The appliance and its individual shutoff valve must be disconnected from the gas supply pip ing system during any pressure testing of that system at test pressures in excess of 1 2psig 3 5 K...

Страница 24: ...llation is the reverse of these steps NOTE Before reinstallation ensure that all old sealant material is scraped off and removed from the fire box bottom and burner pan Verify that the sealing area is...

Страница 25: ...rner tube by sliding it towards the right hand side 4 If the Upper Clips 2 and Lower Panel Brackets 2 are preinstalled then remove them 5 Tilt the Back Panel backwards and slide it into place The Back...

Страница 26: ...bly by unfastening the two 2 screws holding it in Remove the two 2 back screws of both the Lower Latch assemblies NOTE These screws will be used to fasten the Liner Holder brackets 2 Place the rear po...

Страница 27: ...above on this label If you don t smell gas then go to the next step 7 Now push in the control knob slightly and turn 4 counter clockwise to the PILOT position 8 Push in the control knob all the way a...

Страница 28: ...d also be inspected monthly to ensure proper operation Flame should appear similar to the above picture Conversion Kit Instructions PART A Kit Number Description Pilot Orifice Burner Orifice Brass 100...

Страница 29: ...ght and remove it from the assembly Make note of where the Air Shutter is and the screw used to secure it 3 Remove the main orifice using a 1 2 wrench and replace it with the new conversion kit orific...

Страница 30: ...e new injector is proper for the application The injector size is stamped on the side of the injector near the top LPG injectors have a groove machined around their circumference near the top while NG...

Страница 31: ...Gas Conversion for Modulator PART C WARNING WARNING 31...

Страница 32: ...the remote Contrary to this feature is a Manual HI LO Control Knob The Modulating Servo Motor requires the Remote system to be present Backup Battery Pack This component permits the IPI system to oper...

Страница 33: ...ol wiring harness instead of the main IPI harness From the Remote wiring harness use its male plug in connector and connect it to the female plug in in the main IPI harness Now the circuit is complete...

Страница 34: ...Configuration 1 Basic manual HI LO and manual ON OFF capabilities 34...

Страница 35: ...Receiver Module 584 523 521 221 1001 P221SI Receiver Module 584 523 521 221 1001 P221SI 35...

Страница 36: ...ent LIGHTING INSTRUCTIONS 1 STOP Read the above safety information on this label 2 Remove batteries from Receiver and or Battery Backup Pack 3 Turn off all electric power to the fireplace 4 This firep...

Страница 37: ...combustion air inlet to any other appliance In Canada 6in 15cm for appliances 10 000 BTUh 3kW 12in 1 30cm minimum for 1 In accordance with the current CSA B149 1 Natural Gas and Propane Code 2 In acc...

Страница 38: ...Top of horizontal is 1 1 2 3 8cm Top of 90 degree elbow in an enclosure over 44 112cm is 2 1 2 6 4cm Venting terminal shall not be recessed into a wall or siding Venting Routes and Components Since it...

Страница 39: ...2 20 6 1 8 2 4 20 6 1 18 5 5 20 6 1 9 2 7 20 6 1 19 5 8 20 6 1 10 3 0 20 6 1 20 6 1 20 6 1 11 3 4 20 6 1 25 7 5 15 4 6 12 3 7 20 6 1 30 9 0 10 3 0 13 4 0 20 6 1 40 12 2 0 0 Table 2 Horizontal Vent Ta...

Страница 40: ...alling the pipe expand it com pletely and then cut off the remaining length A flex pipe can be expanded to twice their shipped length e g 4ft to 8ft Do not use more than 2 couplers to extend short pip...

Страница 41: ...ealant NOTE It is critical to the proper and safe operation of this fireplace that on all connections the inner liner and the outer casing are both caulked with liberal amounts of sealant Do not use a...

Страница 42: ...ent Termination must not be recessed into wall or siding Figure 26 Side wall hole dimensions for flush wall installations For other installations where the unit is far away from the wall ensure that t...

Страница 43: ...uring the flex and rigid pipe are secured 4 flex pipe must be secured the same way with 4 screws but must penetrate the 4 flex and 4 section of termination Attach 7 rigid pipe to 7 termination with se...

Страница 44: ...the plate to the roof deck then cement the shingles to the plate with a suitable waterproof mastic Ensure that the chimney is plumb Square up the flashing plate and nail in place to the roof deck Use...

Страница 45: ...re to do so will result in improper combustion and emission of harmful gases and can lead to personal injuries Figure 29 Log C 19 parts list Figure 29 Log C 19 parts list Figure 31 Step 1 Place LOG 1...

Страница 46: ...e 35 Step 5 Place Ember Rocks on the front burner tube and ember plate as shown DO NOT PLACE EMBER ROCKS ON THE REAR BURNER TUBE Figure 36 Step 6 Place Lava Rock on the bottom of the firebox IN FRONT...

Страница 47: ...9FK Fan Kit w Variable Speed Temperature Sensing MQ19PL Porcelain Reflective Panel Liner MQ19RL Brick Liner Z1MT Thermostat Millivolt Wall Mount Z80PT Thermostat Programmable Digital Millivolt Millivo...

Страница 48: ...zontal Square Termination Vent Starter Kit 3 Length Horizontal Vent Termination Wall Thimble Wall Thimble 36 Flex Pipe Mill Pac FDVVT40 Vertical Vent Termination FDVHT Horizontal Round Termination FDV...

Страница 49: ...ge Check generator with millivolt meter Take reading at generator terminals of gas valve Should read 325 millivolts minimum while holding valve knob depressed in pilot position and wall switch off Rep...

Страница 50: ...service or maintenance h damage repairs inoperation or inefficiency resulting from faulty installation or application i electricity or fuel costs or any increase in electricity or fuel cost whatsoeve...

Отзывы: