Porcelain Liner Installation Guide
The installation procedure for the porcelain liner requires an additional mounting bracket: the
Porcelain Rear Bracket. This bracket is used to position both sides and the rear panel in place.
Note: It is imperative to position the panels tightly against the walls of the firebox to ensure proper
combustion and operation of the appliance.
CAUTION: Before operating the appliance, ensure that any screws removed from the fire-
box is returned to its original position for proper sealing. Check the condition of the screws
and their respective holes for signs of leakage. Refrain from operating the appliance and
consult a service technician immediately if leakage is found.
1.
Remove the glass door (see page 1
8
), and the Grate assembly by unfastening the two [2]
screws holding it in. Remove the two [2] back screws of both the Lower Latch assemblies.
NOTE: These screws will be used to fasten the Liner Holder brackets.
2.
Place the rear porcelain panel onto the back of the firebox.
3.
Slightly tilt the side panels and slide them into place. Raise the side panels and prop them on
the Liner Holder brackets. Ensure the side panels are tight against the walls of the firebox and
the rear panel. Adjust the Liner Holder brackets accordingly. Fasten the Liner Holder brackets
in place when the panels are tight against the walls of the firebox.
4.
Slide the Porcelain Rear bracket into the firebox and tightly against the rear panel.
Be careful
not to scratch the porcelain finish of the panels.
Once all panels are tight against the fire-
box walls, fasten the Porcelain Rear bracket onto the baffle with the supplied self-piercing DT
screws.
5.
Reinstall any parts that were removed in the installation.
26
Содержание Marquis Serenity MQZDV1917
Страница 10: ...General Framing Installations Figure 5 General framing installation 10...
Страница 31: ...Gas Conversion for Modulator PART C WARNING WARNING 31...
Страница 34: ...Configuration 1 Basic manual HI LO and manual ON OFF capabilities 34...
Страница 35: ...Receiver Module 584 523 521 221 1001 P221SI Receiver Module 584 523 521 221 1001 P221SI 35...