6
Mobile Home/Manufactured Housing Installation
This Direct Vent System Appliance must be installed in accordance with the manufacturer’s installation instructions and the
Manufactured Home Construction and Safety Standard Title 24 CFR, Part 3280, or the current Standard for Fire Safety
Criteria for Manufactured Home Installations, Sites, and Communities ANSI/NFPA 501A, and with CAN/CSA Z240 MH
Mobile Home Standard in Canada.
Figure 1 - Mobile Home Installation.
THE MQRB5143N AND MQRB5143LP MAY BE INSTALLED IN MANUFACTURED (MOBILE) HOMES AFTER FIRST
SALE IN THE USA. IN CANADA THE MQRB5143N AND MQRB5143LP MAY BE INSTALLED IN MANUFACTURED
(MOBILE) HOMES.
Please follow the current ANSI/NFPA 70 National Electrical Code in the USA and CAN/CSA C22.1 Canadian National
Electrical Code in Canada.
An appliance must be grounded to the steel chassis of the home with 8ga copper wire using a serrated or star washer to
penetrate paint or protective coating to insure grounding.
Use carriage bolt at the attachment point (see diagram above) to secure the appliance to the floor.
Warning:
Do not compromise the structural integrity of the manufactured home
wall floor or ceiling during installation of appliance or venting.
For required venting components see venting installation in appropriate section of this manual.
Certified for installation in a bedroom or bedsitting room. In Canada must be installed
with listed millivolt thermostat. In USA see local codes.
Содержание Marquis Infinite MQRB5143LP
Страница 30: ...30 Millivolt System Lighting and Burner Control...
Страница 39: ...39...
Страница 41: ...41 Photos Bottom of Unit with IPI Module Light Module IPI Valve...
Страница 42: ...42 Close up View of IPI Module Inside of IPI Module...
Страница 43: ...43 IPI Valve IPI Valve...
Страница 44: ...44 Millivolt Valve Light Module Millivolt Valve...
Страница 49: ...49 Venting Examples All horizontal runs have a minimum rise per foot...
Страница 57: ...57 Warranty...