33
Gas Conversion for Top Convertible Pilot (Series 019065X)
1. Shut off the gas supply to the appliance.
2. Allow the pilot burner to cool to room
temperature. WARNING: Touching a hot pilot
burner can result in injury.
3. The pilot hood is held in place by spring
pressure. Remove the hood by pulling it
directly up from the pilot bracket (a).
4. Insert a 5/32” or 4mm Allen wrench into the
hexagonal key-way of the injector (b), and
rotate it
counter-clockwise until it is free of
the injector journal (c).
5. Verify that the new injector is proper for the
application. The injector size is stamped on the
side of the injector near the top. LPG injectors
have a groove machined around their
circumference near the top, while NG injectors
do not have a groove (e). Refer to the
Appliance Manufacturers instruction sheet for
the proper injector size.
6. Insert the Allen wrench into the end of the
injector. Then, insert into injector journal, and
rotate the injector clockwise until a torque of 9
in-lbs is achieved.
7. Replace the pilot hood by aligning the tab on
the base of the hood with the slot in the side of
the pilot journal, and push the hood down,
directly onto the pilot bracket (d). The hood
must sit squarely on the bracket for proper
operation. Check to insure that the hood is
properly seated onto the pilot bracket.
(a)
(b)
(c)
(d)
(e)
WARNING
This conversion kit must only be applied as part of a conversion kit supplied by the appliance Manufacturer for
the specific appliance, and type of gas being converted. INSTALLER NOTICE: These instructions must be left
with appliance.
Instructions for converting SIT 190 series pilot burner injection from NG to LPG and from NG to LPG only. This
information should be considered as supplemental to the Appliance Manufacturer’s Instructions.
WARNING!
The installation of this conversion kit must only be undertaken by a qualified and certified gas appliance
installer.
Содержание Marquis Infinite MQRB5143LP
Страница 30: ...30 Millivolt System Lighting and Burner Control...
Страница 39: ...39...
Страница 41: ...41 Photos Bottom of Unit with IPI Module Light Module IPI Valve...
Страница 42: ...42 Close up View of IPI Module Inside of IPI Module...
Страница 43: ...43 IPI Valve IPI Valve...
Страница 44: ...44 Millivolt Valve Light Module Millivolt Valve...
Страница 49: ...49 Venting Examples All horizontal runs have a minimum rise per foot...
Страница 57: ...57 Warranty...