Important
Information
INSTALLATIONS
The following label (supplied with the gas fireplace insert) must be attached with rivets or screws to the inside of the
firebox of the fireplace into which it is installed:
Cutting any sheet-metal parts of the fireplace, in which the gas fireplace insert is to be installed, is prohibited.
If the factory-built fireplace has no gas access hole(s) provided, an access hole of 1.5 in (37.5 mm) or less may be drilled
through the lower sides or bottom of the firebox in a proper workmanship like manner. This access hole must be plugged
with non-combustible insulation after the gas supply line has been installed.
The fireplace flue damper can be fully blocked open or removed for installation of the gas fireplace insert.
Ensure that existing chimney cleanouts fit properly.
refractory, glass doors, screen rails, screen mesh and log grates can be removed from the fireplace before installing the
gas fireplace insert.
Smoke shelves, shields and baffles may be removed if attached by mechanical fasteners.
Trim panels or surrounds must not seal ventilation openings in the fireplace.
The fireplace and fireplace chimney must be clean and in good working order and constructed of non-combustible
materials.
MAINTENANCE
If for any reason the vent air intake system is disassembled, re-install and re-seal per the instructions provided for the
initial installation. See “Installation of Vent Pipe” section.
It is recommended to annually inspect and clean the Burner System to prevent malfunction and / or sooting. This
operation should be performed by your dealer or a qualified technician. Refer to Burner System Maintenance section.
Venting systems should be periodically examined by a qualified agency.
Periodically remove the logs from the grate assembly and vacuum any loose particles from the grate and burner areas.
See Log Placement page to remove logs. Vacuum burner parts and replace logs.