IDV26/IDV33/IDV36 Clearance to Combustible Mantels
Before installing any mantels it is important to determine the combustibility of its material(s). There are two types of mantel
materials to consider: Combustible and Non-combustible.
A Combustible Mantel is one that consists of material(s) that may discolor, combust, or lose its integrity in the presence of
heat. These types of mantel must strictly adhere to the dimensional requirements shown in the figures below. Conversely,
a Non-combustible Mantel is one that is constructed with materials that can withstand temperatures above 250°F [121°C].
Non-combustible Mantels can be installed at any height above the fireplace opening and thus not restricted to the
clearance requires. Check your local codes and regulations to determine whether your mantel is combustible or non-
combustible.
Mantel Leg Clearance
Louver Kit Units
I33LK
I36LK
A
10” 11”
B
12” 13”
C
14” 15”
D
16” 17”
E
18” 19”
F
20” 21”
Clean View Unit
I26CV I33CV I36CV
G
16” 16” 19.5”
H
18” 18” 21.5”
I
20” 20” 23.5”
J
22” 22” 25.5”
K
24” 24” 27.5”
L
26” 26” 29.5”
WARNING:
Combustible objects must
not be placed on a non-combustible mantel
unless the non-combustible mantel meets
the minimum height and width requirements
for a combustible mantel.
(IDV26 This Side Only)
(IDV26 This Side Only)