FDV350 Dimensions
Gas Inlet is located at the back of the unit.
FDV350 Locating Your Appliance
The unit should be placed on a hard, stable surface. Appliance may be installed directly on carpeting, tile or other
combustible material with no additional floor protection being required.
This unit has been tested in an Alcove. Minimum Dimensions of Alcove are as follows:
Depth 30", Height 55.5", Width 52.5".
THE FOLLOWING MINIMUM DISTANCES TO
COMBUSTIBLES MUST BE OBSERVED TO
ENSURE SAFE OPERATION OF YOUR STOVE.
Side of Unit
12”
Back of Unit
3”
Side of Unit in corner (45°) Installation
3”
Top of 90° Elbow
4”
Top of Horizontal Pipes
2-
1/2”
Clearance to Vertical Venting
1”
All other existing pipes
1”
12”
3”
3”
3”
4”
2-
1/2”
1”
9