F35BVC B-Vent Converter - Venting Information
-QUALIFIED INSTALLERS ONLY-
THIS B-VENT CONVERTER MUST BE INSTALLED VERTICALLY AS SHOWN.
A CHIMNEY VENTING THIS STOVE SHALL NOT VENT ANY OTHER APPLIANCE.
-FOLLOW ALL LOCAL CODES-
This appliance may be vented in various
types of applications, including:
A masonry clay lined chimney
A solid fuel wood burning
chimney
A B-Vent liquid fuel gas burning
chimney
A B-
Vent liquid fuel gas chimney or 4” Flex pipe may be used.
When installing with B-Vent liquid fuel gas chimney, install as per B-Vent
Manufacturer installation specifications.
Horizontal, Vertical, and offset installations are allowed.
NOTE: Installation of
B-Vent must follow B-vent Manufacturers Installation Instructions when
being used.
Follow the B-Vent chart for horizontal, vertical, or offset venting.
Minimum venting is 12 ft.
Maximum venting is 60ft.
Seal all connections in venting system.
A 90° elbow can be
installed directly onto
the top of the B-Vent
Converter.
57-
1/4” MINIMUM
MASONRY CLAY LINED CHIMNEY:
Liner
required if inside diameter is greater than 5”.
SOLID FUEL WOOD BURNING CHIMNEY:
Liner required if inside diameter is greater
than 6”.
A 90° elbow can be installed
directly onto the top of the B-Vent
Converter (Minimum Height to top
of elbow is
57-
1/4”
).
B-Vent
Converter
B-Vent Converter
Rain Cap Termination
Storm Collar
Flashing
Attic
Insulation
Shield
Enclosure
Firestop Spacer
Underside of Joist
Firestop
B-Vent Converter
B-VENT LIQUID FUEL GAS BURNING CHIMNEY:
Liner required if inside diameter is greater than 6”.
A 90° elbow can be
installed directly onto the
top of the B-Vent
Converter (Minimum
Height to top of elbow is
57-
1/4”
).
46