LOW ENCLOSURE
ZCV3622 / ZCVRB3622 Framing Dimensions and Clearances
-With Factory Installed Flue Restrictor Removed-
RESTRICTOR MUST BE REMOVED BEFORE INSTALLATION
NOTE:
Units above the following Serial Numbers will have the Flue Restrictor:
ZCV3622 #2016 / ZCVRB3622- #10674
Determine whether face of fireplace will be:
Flush with finished wall (e.g., for surround, cultured stone or other non-combustible covering).
Flush with framing (to be covered with concrete board for a Flat Wall appearance).
Refer to Nailing Tab Guide section also.
Clearance to Combustibles ZCV3622 / ZCVRB3622
Front
36” [92cm]
Back (from Stand-offs)
0” [0cm]
Side (from Stand-offs)
0” [0cm]
Floor
*
0” [0cm]
Minimum Ceiling Height (from
bottom of fireplace)
46-1/2”
Top (from Stand-offs)
0” [0cm]
Top of 90° Bend in minimum
Enclosure of 46-1/2”
10” [25.4cm]
Top of 90° Bend in minimum
Enclosure over 46-1/2”
10” [25.4cm]
*See Chart on right
VENTING SYSTEMS
Top of Horizontal Pipe
1/1/2” [3.8cm]
Side & Bottom of Horizontal Pipe
1” [2.5cm] All Vent
Systems
Vertical Vent Pipe
1” [2.5cm] All Vent
Systems
Seal rivet hole after removing
rivet.
RESTRICTOR REMOVAL
(Restrictor must be removed)
These structures are not load bearing.
NOTE:
See
Nailing Tab Guide
section also.
33” MIN for NG
45” MIN for LP
Plus Rise of 1/4”
Per Foot*
RIGHT SIDE
*For Propane Horizontal installations the venting must be an additional one foot above the minimum vertical rise off
the flue before going horizontal.
*Note: If appliance is installed directly on carpeting or other
combustible material other than wood flooring, a metal or
wood panel extending the full width and depth of the
appliance must be used. Carpet may extend 1 inch above
the floor of the appliance.
*Clearance to Top of 90° bend can
be reduced by 1” for every 2”
increase in height to a minimum of 2”
Enclosure Height
Top of 90° Bend
46-1/2”
10”
48-1/2”
9”
50-1/2”
8”
52-1/2”
7”
54-1/2”
6”
56-1/2”
5”
58-1/2”
4”
60-1/2”
3”
62-1/2”
(and Above)
2”
Restrictor is inside 4” flue.
Use a 1/8” Drill to remove rivet
.
For Low Enclosure Framing.
Lowest enclosure possible
For Propane is 58
”
Min Term Height = 45”
Top of Pipe = 49”
9” Clearance = 58”
Minimum Enclosure Height
for Propane is 58”
15
Содержание ZCV3622LP
Страница 28: ...Optional Log 4 in raised position LOG 4 28...
Страница 45: ...Gas Conversion for Modulator PART C 45...
Страница 51: ...Configuration 1 Basic manual HI LO and manual ON OFF capabilities 51...
Страница 52: ...Receiver Module 584 523 521 221 1001 P221SI Receiver Module 584 523 521 221 1001 P221SI 52...
Страница 59: ...Proflame 2 Remote Control 59...
Страница 61: ...61...