background image

 

 

 

 

This Limited Lifetime Warranty applies only while the unit remains at the site of the original installation 
and  only  if  the  unit is  installed  inside  the  continental  United  States,  Alaska,  Hawaii,  and  Canada.  The 
warranty applies only if the unit is installed and operated in accordance with the printed instructions and 
in compliance with applicable installation and building codes and good trade practices. 

BASIC ONE YEAR WARRANTY 

During  the  first  year  after  installation,  we  will  provide  a  replacement  for  any  component  part  of  your  unit  found  to  be  defective  in 
materials  or  workmanship,  including  labour  costs.  Repair  work  requires  prior  approval  by  Kingsman,  labour  costs  are  based  on  a 
predetermined rate schedule and any repair work must be done through an authorized Kingsman dealer. 
(Excluded Components: Accent Light Bulbs, Gasketing and Paint) 

LIMITED LIFETIME WARRANTY 

The heat exchanger, combustion chamber and burner of every Kingsman product excluding the Outdoor Firepit are warranted again st 
materials or workmanship during the period the product is owned by the original owner. The part to be replaced must be returned to our 
distributor  in  exchange  for  the  replacement  part.  Any  labor,  material,  freight  and/or  handling  charges  associated  with  any  repair  or 
replacement pursuant to this Limited Lifetime Warranty will not be covered by this warranty.  

GENERAL TERMS 

In lieu of providing a replacement part, we may, at our option, provide the distributor's component purchase price from us or a credit 
equal to the 

distributor’s component purchase price from us toward the purchase of any new unit which we distribute. If a credit is given 

in lieu of a replacement part, the rating plate from the unit being replaced must be submitted on a warranty claim, and the unit being 
replaced must be made available to our distributor for disposition.  

In establishing the date of installation for any purpose, including determination of the starting date for the term of this Limited Lifetime 
Warranty, reasonable proof of the original installation date must be presented*, otherwise the effective date will be based upon the date 
of manufacture plus thirty (30) days.  

We  will not be  responsible for  and  you,  the  user,  will pay  for:  (a)  damages caused by  accident,  abuse,  negligence, misuse,  ri ot,  fire, 
flood, or Acts of God (b) damages caused by operating the unit where there is a corrosive atmosphere containing chlorine, fluorine, or 
any other damaging chemicals (other than in a normal residential environment) (c) damages caused by any unauthorized alteration or 
repair of the unit affecting its stability or performance (d) damages caused by improper matching or application of the unit or the unit's 
components  (e)  damages  caused  by  failing  to  provide  proper  maintenance  and  service  to  the  unit  (f)  any  expenses  incurred  for 
erecting, disconnecting or dismantling the unit (g) parts or supplies used in connection with service or maintenance (h) damage repairs, 
inoperation or inefficiency resulting from faulty installation or application (i) electricity or fuel costs or any increase in electricity or fuel 
cost whatsoever including additional or unusual use of supplemental electric heat.  

We shall not be liable for any incidental, consequential, or special damages or expenses in connection with any use or failure of this 
unit.  We  have  not  made  and  do  not  make  any  representation  or  warranty  of  fitness  for  a  particular  use  or  purpose,  and  there  is  no 
implied condition  of  fitness  for  a  particular  use  or  purpose. We make  no  express  warranties  except  as  stated  in  this  Limited  Lifetime 
Warranty.  No  one  is  authorized  to  change  this  Limited  Lifetime  Warranty  or  to  create  for  us  any  other  obligation  or  liability  in 
connections with this unit. Any implied warranties shall last for one year after the original installation. Some states and provinces do not 
allow the exclusion or limitation of incidental or consequential damages or do not allow limitations on how long an implied warranty or 
condition lasts, so the above limitations or exclusions may not apply to you. The provisions of this limited warranty are in  additions to 
and not a modification of or subtraction from any statutory warranties and other rights and remedies provided by law.  

Save  this  certificate.  It  gives  you  specific  legal  rights,  and  you  may  also  have  other  rights  which  may  vary  from  state  to  state  and 
province to province.  

In the event your unit needs servicing, contact your dealer or contractor who installed or serviced your unit. When requesting service, 
please have the model and serial number from each unit readily available. If your dealer needs assistance, the distributor is available 
for support and we, in turn support the distributor's efforts.  

Fill in the installation date and model and serial numbers of the unit in the space provided below and retain this limited warranty for your 
files.  

 

Model No. 

 

Serial No. 

 

Date installed 

 

 

Dealer or Contractor Name:  

 

*To receive advantage of your warranty, you must retain the original records that can establish the installation date of your unit. 

 

The Ultimate in Design, Engineering & Quality 

 

68

Содержание HBZDV3624

Страница 1: ...e foot vertical off the flue before going horizontal A Division of R Co Inc 2340 Logan Avenue Winnipeg Manitoba Canada R2R 2V3 Ph 204 632 1962 Printed in Canada August 28 2019 Part 36HB MAN17 INSTALLE...

Страница 2: ...GC44 Placement 24 26 MQLOGC45 Oak Logset Placement 27 28 MQRSP3 with Pilot Shield 29 Installing MQRSP3 30 Pilot Shield RSP1 RSP2 31 MQROCK1 MQRSP3 32 33 Burner System Gas Line Installation 34 Millivol...

Страница 3: ...izontal Venting Table From Bottom of Fireplace 58 Venting Straight Up Through Roof 59 60 Fireplace Installations Using Co Linear Flex Kits 61 Glass Safety Termination Cap Safety 62 Approved for Power...

Страница 4: ...e sounds produced by a furnace or heating duct This noise does not affect the operation or longevity of your fireplace It is also normal for the fan to make some noise when it comes on This noise can...

Страница 5: ...until unit is COMPLETELY cool before touching glass or attempting to install or remove Child Safety Screens To install screens hook bottom clip onto glass door frame then press down and push upper cli...

Страница 6: ...frequent cleaning may be required due to excessive lint from carpeting bedding material et cetera It is imperative that control compartments burners and circulating air passageways of the appliance b...

Страница 7: ...installation D A metal or plastic identification plate shall be mounted at the exterior of the building four feet directly above the location of vent terminal The plate shall be of sufficient size to...

Страница 8: ...DV3628LP LPE LPE2 MAY BE INSTALLED IN MANUFACTURED MOBILE HOMES Please follow the current ANSI NFPA 70 National Electrical Code in the USA and CAN CSA C22 1 Canadian National Electrical Code in Canada...

Страница 9: ...r to the indoor gas fireplace being installed A Minimum sheltering cover overhang of 1 2 the distance from the base of the fireplace to the ceiling base of roofline is required EXAMPLE The bottom of t...

Страница 10: ...on Wall Corner F Exterior Wall See Mantel Leg Clearances Instruction for the proper placement of fireplace Island installation with a top vent is possible as long as the horizontal portion of the vent...

Страница 11: ...a 90 degree bend maintain a minimum of two and a half 2 5 inches above the bend in enclosures 5 Hearth is not mandatory but is recommended for aesthetic purposes For HBZDV with louvers combustible fl...

Страница 12: ...HBZDV36 WITH HB36CVCK CLEAN VIEW CIRCULATING KIT HBZDV36 Framing and Facing Requirements Non Combustible Header Attached AA Non Combustible Header Attached AA AA AA AA 12...

Страница 13: ...fireplace 60 inches 150 cm Top from standoffs 0 inches 0 mm Top of 90 degree bend in Minimum Enclosure of 42 to 43 inches 3 1 2 inches 89 mm All Vent Systems Top of 90 degree bend in Enclosure over 43...

Страница 14: ...he top trim and bracket together 2 Place Lower Trim onto fireplace 5 Push bottom side of trop trim toward fireplace The lip on the bottom side of top trim must be inserted into fireplace 3 Attach left...

Страница 15: ...s HB36 HB42 HB47 Mantels Warning Combustible objects must not be placed on a non combustible mantel unless the non combustible mantel meets the minimum height and width requirements for a combustible...

Страница 16: ...r over the front face of the fireplace NO PORTION OF GRILL AREA OR DOOR AREAS CAN BE COVERED except where designer clean view kit is used Combustible material can extend flush to unit up to the top bo...

Страница 17: ...Fan Installation for HBZDV 36 42 47 17...

Страница 18: ...rounding plug for your protection against shock hazard and should be plugged directly into a properly grounded three prong receptacle Label all wires prior to disconnection when servicing controls Wir...

Страница 19: ...3624 AND HBZDV3628 1 Place rear brick panel against rear of fireplace 2 Loosen screws holding brick clips in position Rotate clips up out of the way 3 Place bottom of side brick over front lip of fire...

Страница 20: ...firebox by tilting top of Back Panel towards you and sliding bottom of Back Panel over burner system For HB47PL use supplied screw to attach Back Panel to firebox See Ref 2 4 Loosen screws holding Bri...

Страница 21: ...tension is lost 1 To remove the top latch remove the 2 hex screws that secure it in place They are located in the firebox 2 Once all the screws are removed the latches will slide out of place 3 There...

Страница 22: ...ront burner to the surface of the ember plates and over crossover to the same height as ember plates Height on front burner 1 2 to 3 4 Height on ember plates 3 4 to 1 Do not cover back air openings on...

Страница 23: ...ght crossover log across front and back logs using the log placement pin as a guide Step 8 Place left crossover log across front and back logs using the log placement pin as a guide Step 9 Place decor...

Страница 24: ...1 Position rear log over rear log holder and lower into position Be sure that the log does not sit on rear burner but behind and lower than burner Step 2 Locate flat surface on Log 2 and place directl...

Страница 25: ...terial from plastic bag tear off dime and nickel sized pieces and place directly onto front burner tube and crossover tube NOTE Do not place embers onto rear burner tube Step 5 Position Log 4 into gro...

Страница 26: ...e 3rd grate post from the right and position upper section of Log 8 against Logs 2 and 7 Step 10 Place crushed rocks onto firebox bottom NOTE Do not place crushed rock onto burner tubes 6 7 8 LOGC44 P...

Страница 27: ...irebox Floor and against left side of Grate Bar Step 3 Rest the Small Branch end of Log 3 onto Rear Log Holder Next place Flattened area of Log 3 onto firebox floor between the right end of Grate Bar...

Страница 28: ...ace Log 6 onto Log 1 and Log 5 making sure to position between the end and center flames evenly There should be no impingement of flames or sooting may occur Step 8 Place Log 7 onto empty spot on Rear...

Страница 29: ...h Pilot Shield WARNING Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage or personal...

Страница 30: ...to burner system without pre punched holes 1 Use the rock platform as a template for the holes to be drilled Center platform on burner system 1 from the back of firebox Ref 1 and mark the location of...

Страница 31: ...Pilot Shield RSP1 RSP2 Qty 1 Shield Per Kit Back View 1 2 3 4 5 6 SLOTS SLOTS SLOTS SLOTS 31...

Страница 32: ...ock platform mount holes attach the rock platform to the burner pan as shown STEP 4 Fill around the rock platform with lava rock Sprinkle vermiculite over top of the lava rock Do not place lava rock o...

Страница 33: ...s STEP 6 Place rocks 3 into position as shown Do not place rocks directly onto the burner tubes STEP 7 Place rocks 4 into position as shown STEP 8 Place rocks 6 into position as shown STEP 9 Place rem...

Страница 34: ...Gasline Installation Gasline Specifications HBZDV3624N NE NE2 HBZDV3624LP LPE LPE2 HBZDV3628N NE NE2 HBZDV3628LP LPE LPE2 34...

Страница 35: ...ly the pilot burner located on the rear center left hand side of the main burner If a flame has appeared then continue to depress the control knob for 20 seconds If the flame did not appear then conti...

Страница 36: ...ition of vent and vent terminal for sooting or obstruction and correct if present 6 Vacuum and clean any debris in the firebox that is not supposed to be there 7 Test and measure the flame failure res...

Страница 37: ...ck log holder on applicable units only and remove Remove screws from perimeter of burner system pan lift pan at one back corner and rotate pan up from back of firebox Make sure when tilting up and rem...

Страница 38: ...ART A Kit Number Description Pilot Orifice Burner Orifice Brass 1000 255 Brass Nipple Air Shutter Hi Lo Regulator 3624HB CKLP 3628HB CKLP Propane Conversion Millivolt 1001 P167SI 30 977 167 53 52 1000...

Страница 39: ...to the correct opening using a drill bit or tape measure Retighten screw Reinstall burner at this time reversing STEPS 3 2 and 1 11 Follow instructions supplied with the conversion HI LO to convert t...

Страница 40: ...njector near the top Propane injectors have a groove machined around their circumference near the top while NG injectors do not have a groove fig 4 Refer to the Appliance Manufacturer s instruction sh...

Страница 41: ...Gas Conversion for Modulator PART C WARNING WARNING 41...

Страница 42: ...ppliance is still operable NOTE In certain instances the IPI Main Module requires resetting This can occur if the system is unable to ignite the pilot or the main burner in the allotted time period Th...

Страница 43: ...splay on the Transmitter will change to show that the room thermostat is ON and the set temperature is now displayed To adjust the set temperature press the Up or Down Arrow Keys until the desired set...

Страница 44: ...or 1002 P910si Electrode Flame Sensor 35 Length 5 1002 P302si IPI Ignition Board 6 1002 P850si AC Wall Adapter 7 1002 P12BH Battery Pack 8 1002 P912si Wiring Harness 9 1001 P166si Orifice Pilot NG 62...

Страница 45: ...Configuration 1 Basic manual HI LO and manual ON OFF capabilities 45...

Страница 46: ...Receiver Module 584 523 521 221 1001 P221SI Receiver Module 584 523 521 221 1001 P221SI 46...

Страница 47: ...er Adapter P N 1002 P850si The Remote Receiver IPI or Millivolt system can be powered by the AC Adapter This is advantageous if you do not want to use batteries Simply connect the AC Adapter into the...

Страница 48: ...Configuration 3 Remote ON OFF variable HI LO and fan capabilities Refer to the fan installation removal section for fan installation 48...

Страница 49: ...clockwise to off Located behind the access panel 7 Wait five 5 minutes to clear out any gas Then smell for gas including near the floor If you smell gas STOP Follow B in the safety information above...

Страница 50: ...13 1002 P047SI TC Pilot Burner IPI Assembled LP 199 047 14 1001 P166SI TC Orifice Pilot NG 977 166 62 IPI 15 1001 P168SI TC Orifice Pilot LP 977 168 35 IPI 16 1001 P280SI TC Tubing W Fittings 1 8 2 1...

Страница 51: ...d to reset the PF2 Module Press the Red SW1 button until you hear three beeps Within 10 seconds press the SW1 button again until you hear it beep The PF2 module may now be turned on off manually x4 co...

Страница 52: ...ON OFF and the pilot is also out follow the procedures described in this manual to light the pilot To switch from IPI to CPI Mode 1 Turn the fireplace OFF using the ON OFF Key 2 Press the Mode Key Dis...

Страница 53: ...Proflame 2 Remote Control 53...

Страница 54: ...Note When Smart Thermostat is activated manual flame height adjustment is disabled Note This function is only available in Room Thermostat or Smart Thermostat Control Mode 54...

Страница 55: ...55...

Страница 56: ...u h 3 kW and 50 000 Btu h 15 kW 12 in 30 cm for appliances 50 000 Btu h 15 kW K Clearance to a mechanical air supply inlet 6 ft 1 83 m 3 ft 91 cm above if within 10 ft 3 m horizontally L Clearance abo...

Страница 57: ...es provided in this manual Apply a bead of Mill Pac high temp sealant to all joints of pipes adapters and termination when using Kingsman Flex Z Flex Venting venting and Simpson Duravent venting NOTE...

Страница 58: ...ht of the system and the number of bends required 2 Having determined the vertical distance determine the maxi mum horizontal section allowed 3 Vent table has been established for 90 horizontal vertic...

Страница 59: ...rulers or by using a roof pitch card Slide a Roof Flashing suitable to your roof slope over the vent Place the edge of the flashing plate that will be on the higher part of the roof slope under the sh...

Страница 60: ...upport configuration B Flex bend configuration C Termination mounting Clearance to perpendicular wall 24 inches 60 cm Recommended to prevent re circulation of exhaust products For additional requireme...

Страница 61: ...ance The Intertek safety certification does not apply to this installation Before installing the appliance using this method contact the Authority Having Jurisdiction to determine if this installation...

Страница 62: ...eep toddlers young children and other at risk individuals out of the room and away from hot surfaces Do not leave the fireplace remote control where it is accessible to children Termination Cap Safety...

Страница 63: ...s are permitted however Cold Climate Switch Standing Pilot Mode must NOT be used Seven 90 elbows are possible if the total horizontal is not more than 25ft and the vertical does not exceed 15ft Refer...

Страница 64: ...4 6 5 8 venting to 5 8 For Power Vent installations where flex pipe will be used up to the Power Vent unit Z47PVA Pipe Reducer 8 Sm 7 Sm Pipe Reducer 5 Sm 4 Sm Adapts PVH58 to accept 4 7 Flex Pipe On...

Страница 65: ...stem HBZDV3624N 3624HB BLPSI Burner Assembly Liquid Propane c w Valve System HBZDV3624LP 3628HB BNGSI Burner Assembly Natural Gas c w Valve System HBZDV3628N 3628HB BLPSI Burner Assembly Liquid Propan...

Страница 66: ...verts from 15 40 to under 15 FDVHT Horizontal Vent Termination FDVHSQ Horizontal Square Termination Z47ST24 Horizontal Snorkel Termination 24 Z47ST36 Horizontal Snorkel Termination 36 FDVHSCU Safety C...

Страница 67: ...Check generator with millivolt meter Take reading at generator terminals of gas valve Should read 325 millivolts minimum while holding valve knob depressed in pilot position and wall switch off Replac...

Страница 68: ...other than in a normal residential environment c damages caused by any unauthorized alteration or repair of the unit affecting its stability or performance d damages caused by improper matching or app...

Отзывы: