Framing for your Gas Fireplace
Framing Specifications
1. Cold climate installation recommendation: When installing this fire-
place against non insulated exterior wall or chase, it is recom -
mended that the outer walls be insulated to conform to applicable
insulation codes. Drywall must be installed over insulation to prevent
contact of insulation and unit.
2. Choose fireplace location and frame in accordance with the fireplace
framing dimensions specified (See Framing Diagrams). Bend nailing
tabs forward on left and right of unit and place fireplace into framed
enclosure. This allows for 1/2” in front of framing tabs for finishing
materials.
3. Drywall or other material can extend flush with the appliance on the
bottom, sides and top of fireplace. (louvered models only)
HBZDV36 Louvered
HBZDV36 WITH CVCK (CLEAN VIEW CIRCULATING KIT)
4. When installing horizontal with a 90 degree bend maintain a minimum
of two and a half (2.5”) inches above the bend in enclosures.
5. Hearth is not mandatory but is recommended for aesthetic purposes.
For HBZDV with louvers combustible floor can raise 1” above
the bottom of the fireplace. For HBZDV with CVCK (Clean
view Circulating Kit) floor or hearth can raise 7” above the
bottom of the fireplace with portions being combustible and
non combustible. See drawing below.
6. When installing MQHB36SW surround, the fireplace must be
raised a minimum of 3 1/2” above the finished floors, to
accommodate the wall surround. The fireplace may be raised
higher but the 60” clearance measured from the bottom of the
fireplace to the ceiling must be maintained at all times. (i.e.
For an 8ft ceiling, the unit can be raised only 36 inches.)
8
21
⁄
32
" DIA.
11"
11"
TOP VIEW
For
Propane Horizontal Installations
the venting must be a minimum of one foot vertical off the flue before the elbow on any
horizontal runs of one foot or greater. This allows for cleaner combustion and greatly reduces carboning and cleaning of glass.
11
Содержание HBZDV3624
Страница 17: ...Fan Installation for HBZDV 36 42 47 17...
Страница 31: ...Pilot Shield RSP1 RSP2 Qty 1 Shield Per Kit Back View 1 2 3 4 5 6 SLOTS SLOTS SLOTS SLOTS 31...
Страница 41: ...Gas Conversion for Modulator PART C WARNING WARNING 41...
Страница 45: ...Configuration 1 Basic manual HI LO and manual ON OFF capabilities 45...
Страница 46: ...Receiver Module 584 523 521 221 1001 P221SI Receiver Module 584 523 521 221 1001 P221SI 46...
Страница 53: ...Proflame 2 Remote Control 53...
Страница 55: ...55...