Burner System Maintenance
It is recommended to annually inspect and clean the Burner System to prevent malfunction and / or sooting. This operation
should be performed by your dealer or a qualified technician.
-
CAUTION
-
Before servicing the burner system ensure that the gas supply is turned OFF and disconnect all electrical connections
to the appliance. Allow the appliance to cool to room temperature. Note that the pilot assembly may be hot in an
intermittent or standing-pilot system—even if the main burner was never on. Exercise caution when working within the
area.
-ALL WORK SHOULD BE PERFORMED BY A QUALIFIED AND CERTIFIED TECHNICIAN-
Monthly Flame Inspection
It is recommended to turn on the unit at least once a month and inspect the flame pattern to ensure there are no problems
with the burner tube. The pilot flame should also be inspected monthly to ensure proper operation.
Flame should appear similar to the above picture.
Conversion Kit Instructions – PART A
Kit Number
Description
Pilot Orifice
Burner Orifice
Brass (1000-255)
Brass Nipple
Air Shutter Hi/Lo Regulator
3624HB -CKLP
3628HB -CKLP
Propane
Conversion
-Millivolt-
1001-P167SI
#30 (977.167)
#53
#52
1000-253closed
1000-253closed
Fully Open
Fully Open
1001-P202SI
(0.907.202)
3624HB -CKNG
3628HB -CKNG
NG Conversion
-Millivolt-
1001-P165SI
#51 (977.165)
#42
#37
1000-253closed
1000-253closed
1/8”
7/32”
1001-P201SI
(0.907.201)
3624HB –CKLPI
3628HB -CKLPI
3624HB –CKLP2
3628HB –CKLP2
Propane
Conversion
-IPI -
1001-P168SI
#35 (977.168)
#53
#52
#53
#52
1000-253closed Fully Open
1002-P014SI
1002-P014SI
1002-P012SI
1002-P012SI
3624HB -CKNGI
3628HB -CKNGI
3624HB -CKNG2
3628HB -CKNG2
NG Conversion
- IPI -
1001-P166SI
#62 (977.166)
#42
#37
#42
#37
1000-253closed
1/8”
7/32”
1/8”
7/32”
1002-P016SI
1002-P016SI
1002-P013SI
1002-P013SI
Refer to “
Gas Specifications Chart
” for inlet pressures and input ratings. Clock meter to verify input rate. Place conversion label
as close to converted gas control as possible. Refer to lighting instructions to verify the normal operating sequence of the ignition
system. IMPORTANT: Always check for gas leaks with a soap and water solution. DO NOT USE OPEN FLAME FOR LEAK
TESTING.
38
Содержание HBZDV3624
Страница 17: ...Fan Installation for HBZDV 36 42 47 17...
Страница 31: ...Pilot Shield RSP1 RSP2 Qty 1 Shield Per Kit Back View 1 2 3 4 5 6 SLOTS SLOTS SLOTS SLOTS 31...
Страница 41: ...Gas Conversion for Modulator PART C WARNING WARNING 41...
Страница 45: ...Configuration 1 Basic manual HI LO and manual ON OFF capabilities 45...
Страница 46: ...Receiver Module 584 523 521 221 1001 P221SI Receiver Module 584 523 521 221 1001 P221SI 46...
Страница 53: ...Proflame 2 Remote Control 53...
Страница 55: ...55...