Kingsman Fireplaces FDV200S Скачать руководство пользователя страница 51

 

 

 

 

This Limited Lifetime Warranty applies only while the unit remains at the site of the original installation 
and  only  if  the  unit is  installed  inside  the  continental  United  States,  Alaska,  Hawaii,  and  Canada.  The 
warranty applies only if the unit is installed and operated in accordance with the printed instructions and 
in compliance with applicable installation and building codes and good trade practices. 

BASIC ONE YEAR WARRANTY 

During the first year after installation of the appliance, we will provide a replacement for any component part of your unit found to be 
defective in materials or workmanship, including labour costs. Repair work requires prior approval by Kingsman, labour costs are based 
on a predetermined rate schedule and any repair work must be done through an authorized Kingsman dealer. 
(Excluded Components: Accent Light Bulbs, Gasketing and Paint) 

LIMITED LIFETIME WARRANTY 

The heat exchanger, combustion chamber and burner of every Kingsman product excluding the Outdoor Firepit are warranted again st 
materials or workmanship during the period the product is owned by the original owner. The part to be replaced must be returned to our 
distributor  in  exchange  for  the  replacement  part.  Any  labor,  material,  freight  and/or  handling  charges  associated  with  any  repair  or 
replacement pursuant to this Limited Lifetime Warranty will not be covered by this warranty.  

GENERAL TERMS 

In lieu of providing a replacement part, we may, at our option, provide the distributor's component purchase price from us or a credit equal 
to the 

distributor’s component purchase price from us toward the purchase of any new unit which we distribute. If a credit is given in lieu 

of a replacement part, the rating plate from the unit being replaced must be submitted on a warranty claim, and the unit  being replaced 
must be made available to our distributor for disposition.  

In establishing the date of installation for any purpose, including determination of the starting date for the term of this Limited Lifetime 
Warranty, reasonable proof of the original installation date must be presented*, otherwise the effective date will be based upon the date 
of manufacture plus thirty (30) days.  

We will not be responsible for and you, the user, will pay for: (a) damages caused by accident, abuse, negligence, misuse, riot, fire, flood, 
or Acts of God (b) damages caused by operating the unit where there is a corrosive atmosphere containing chlorine, fluorine, or any other 
damaging chemicals (other than in a normal residential environment) (c) damages caused by any unauthorized alteration or repair of the 
unit affecting its stability or performance (d) damages caused by improper matching or application of the unit or the unit's components (e) 
damages caused by failing to provide proper maintenance and service to the unit (f) any expenses incurred for erecting, disconnecting 
or dismantling the unit (g) parts or supplies used in connection with service or maintenance (h) damage repairs, inoperation or inefficiency 
resulting from faulty installation or application (i) electricity or fuel costs or any increase in electricity or fuel cost whatsoever including 
additional or unusual use of supplemental electric heat.  

We shall not be liable for any incidental, consequential, or special damages or expenses in connection with any use or failure of this unit. 
We have not made and do not make any representation or warranty of fitness for a particular use or purpose, and there is no implied 
condition of fitness for a particular use or purpose. We make no express warranties except as stated in this Limited Lifetime Warranty. 
No one is authorized to change this Limited Lifetime Warranty or to create for us any other obligation or liability in connections with this 
unit. Any implied warranties shall last for one year after the original installation. Some states and provinces do not allow the exclusion or 
limitation of incidental or consequential damages or do not allow limitations on how long an implied warranty or condition la sts, so the 
above limitations or exclusions may not apply to you. The provisions of this limited warranty are in additions to and not a modification of 
or subtraction from any statutory warranties and other rights and remedies provided by law.  

Save this certificate. It gives you specific legal rights, and you may also have other rights which may vary from state to state and province 
to province.  

In the event your unit needs servicing, contact your dealer or contractor who installed or serviced your unit. When requesting service, 
please have the model and serial number from each unit readily available. If your dealer needs assistance, the distributor is available for 
support and we, in turn support the distributor's efforts.  

Fill in the installation date and model and serial numbers of the unit in the space provided below and retain this limited warranty for your 
files.  

 

Model No. 

 

Serial No. 

 

Date installed 

 

 

Dealer or Contractor Name:    

*To receive advantage of your warranty, you must retain the original records that can establish the installation date of your unit. 

 

The Ultimate in Design, Engineering & Quality 

 

51

Содержание FDV200S

Страница 1: ...y or the gas supplier Installation Instructions This appliance may be installed in an aftermarket permanently located manufactured home USA only or mobile home where not prohibited by local codes This...

Страница 2: ...t Part B series 0190XYZ 21 Gas Conversion for Modulator PART C 22 Millivolt System Lighting and Burner Control 23 Electronic Ignition Lighting Instructions 24 Troubleshooting the Gas Control System 25...

Страница 3: ...PARTS LIST FDV200S Parts List 48 49 WARRANTY Glass Safety Termination Cap Safety 50 Limited Lifetime Warranty 51 3...

Страница 4: ...Top Hooks into Top Slots 3 Engage Bottom Hooks into Bottom Slots Top Slot Bottom Hook Top Hook To remove Safety Screen Wait Until Fireplace is Completely Cool and reverse these steps Bottom Hook Top H...

Страница 5: ...sounds produced by a furnace or heating duct This noise does not affect the operation or longevity of your fireplace It is also normal for the fan to make some noise when it comes on This noise can be...

Страница 6: ...condition of vent and vent terminal for sooting or obstruction and correct if present 6 Vacuum and clean any debris in the firebox that is not supposed to be there 7 Test and measure the flame failure...

Страница 7: ...due to excessive lint from carpeting bedding material et cetera It is imperative that control compartments burners and circulating air passageways of the appliance be kept clean Make sure that the ga...

Страница 8: ...ication plate shall be mounted at the exterior of the building four feet directly above the location of vent terminal The plate shall be of sufficient size to be easily read from a distance of eight f...

Страница 9: ...IN MANUFACTURED MOBILE HOMES IN CANADA Please follow the current ANSI NFPA 70 National Electrical Code in the USA and CAN CSA C22 1 Canadian National Electrical Code in Canada An appliance must be gro...

Страница 10: ...rotection being required This unit has been tested in an Alcove Minimum Dimensions of Alcove are as follows Depth 30 Height 55 5 Width 52 5 THE FOLLOWING MINIMUM DISTANCES TO COMBUSTIBLES MUST BE OBSE...

Страница 11: ...Remote Receiver Battery Backup Remote Receiver Battery Backup Piezo Igniter Piezo Igniter Valve Valve Valve Battery Backup Battery Backup Fan Speed Control Fan Speed Control Fan Speed Control Proflame...

Страница 12: ...y remove the Rear Tabs from the unit To Install Component Cover Hook the Rear Tabs over the back of the Component Tray Next attach front of Component Cover with 2 DT screws WARNING Wait until unit is...

Страница 13: ...FDV200S Optional Fan Installation Part F45FK 13...

Страница 14: ...rounding plug for your protection against shock hazard and should be plugged directly into a properly grounded three prong receptacle Label all wires prior to disconnection when servicing controls Wir...

Страница 15: ...oval diagram 2 Place Back Brick Panel up to rear of firebox leaving bottom of panel slightly forward for support 3 Remove left and right Brick Clips using a 1 4 nut driver Do not discard Brick Clips 4...

Страница 16: ...Tabs 3A and 3B Do not place Log 3 on top of Locating Tabs Step 4 Place Log 4 onto notched areas of Log 1 and Log 3 Step 5 Place Log 5 up against the 2nd Grate Bar from the left as shown Step 6 Place G...

Страница 17: ...Door and Glass Information FDV200S Safety Screen Frame Assembly Glass Front Door Assembly Screw Screw 17...

Страница 18: ...olated from the gas supply piping system by closing its individual shutoff valve during any pressure testing of the gas sup ply piping system at test pressures equal to or less than 1 2 PSIG 3 5 KPa G...

Страница 19: ...ription Pilot Orifice Burner Orifice Brass 1000 255 Brass Nipple Air Shutter Hi Lo Regulator 200DV CKLP FDV200SLP Propane Conversion Millivolt 1001 P167SI 30 977 167 1 16 1000 253 closed Full Open 100...

Страница 20: ...to convert the valve from one type of fuel to the other Step 8 Check for gas leaks around the pilot burner tube and face of valve Step 9 Attach conversion label to label plate on bottom of unit writi...

Страница 21: ...njector near the top Propane injectors have a groove machined around their circumference near the top while NG injectors do not have a groove fig 4 Refer to the Appliance Manufacturer s instruction sh...

Страница 22: ...Gas Conversion for Modulator PART C 22...

Страница 23: ...ly the pilot burner located on the rear center left hand side of the main burner If a flame has appeared then continue to depress the control knob for 20 seconds If the flame did not appear then conti...

Страница 24: ...all electric power to the appliance 4 This appliance is equipped with an ignition device which automatically lights the pilot Do not try to light the pilot by hand 5 Wait five 5 minutes to clear out...

Страница 25: ...as valve Should read 325 millivolts minimum while holding valve knob depressed in pilot position and wall switch off Replace faulty generator if reading is below specified minimum Plugged burner orifi...

Страница 26: ...13 1002 P033SI TC Pilot Burner IPI Assembled NG 199 033 14 1002 P047SI TC Pilot Burner IPI Assembled LP 199 047 15 1001 P166SI TC Orifice Pilot NG 977 166 62 IPI 16 1001 P168SI TC Orifice Pilot LP 977...

Страница 27: ...s required The following sequence must be followed to reset the PF2 Module Press the Red SW1 button until you hear three beeps Within 10 seconds press the SW1 button again until you hear it beep The P...

Страница 28: ...the main burner has been cycled ON OFF and the pilot is also out follow the procedures described in this manual to light the pilot To switch from IPI to CPI Mode 1 Turn the fireplace OFF using the ON...

Страница 29: ...Proflame 2 Remote Control 29...

Страница 30: ...Note When Smart Thermostat is activated manual flame height adjustment is disabled Note This function is only available in Room Thermostat or Smart Thermostat Control Mode Halogen lights only 30...

Страница 31: ...iring Diagram For use with all Kingsman manufactured IPI Proflame 2 models for all types of gas noted on rating plate Supply 120VAC 60Hz 3A 6 volts battery backup Pour utilisation avec tous les mod le...

Страница 32: ...ck This component permits the IPI system to operate without the need for an external AC Adapter power source The advantage to using the battery backup is that in the case of a power failure the applia...

Страница 33: ...hat the room thermostat is ON and the set temperature is now displayed To adjust the set temperature press the Up or Down Arrow Keys until the desired set temperature is displayed on the LCD screen of...

Страница 34: ...P 977 168 35 IPI 11 1002 P012SI IPI Stepper Kit LP 907 012 12 1002 P013SI IPI Stepper Kit NG 907 013 13 1002 P014SI IPI Reg Kit LP Hi Lo 907 014 14 1002 P016SI IPI Reg Kit NG Hi Lo 907 016 15 1002 P01...

Страница 35: ...Configuration 1 Basic manual HI LO and manual ON OFF capabilities 35...

Страница 36: ...s with remote HI LO capabilities a modulating servo is required to be installed on the valve The connectors to this servo must be connected to the Remote Harness as shown SCHEMATIC PICTURE NOTE Fan Op...

Страница 37: ...er Adapter P N 1002 P850si The Remote Receiver IPI or Millivolt system can be powered by the AC Adapter This is advantageous if you do not want to use batteries Simply connect the AC Adapter into the...

Страница 38: ...lities Refer to the fan installation removal section for fan installation NOTE Fan Option is not available on some models of fireplace Check with your dealer NOTE This Configuration is not available o...

Страница 39: ...3 m horizontally L Clearance above paved sidewalk or paved driveway located on public property 7 ft 2 13 m Notes 2 M Clearance under veranda porch deck or balcony 12 in 30 cm 12 in 30 cm N Where a ve...

Страница 40: ...g in bend or before and after See Fig 1 Horizontal runs require support metal straps every 2 feet In offset installation support straps should be used to stabilize pipe Expand 4 and 7 flex pipe to the...

Страница 41: ...installed in either the horizontal or vertical runs Minimum clearances on venting 4 to top of elbow 2 1 2 from top of horizontal pipes 1 on all other existing pipes Only trim kit s supplied by the ma...

Страница 42: ...m and the number of elbows required 2 Use the Venting Chart to determine the maximum horizontal distance allowed Note For each 45 elbow installed in the horizontal run the length of the horizontal run...

Страница 43: ...he pipe extends properly through wall thimble and into vent termination 7 Before joining pipes to fireplace flue apply a bead of high temperature sealant Mill Pac to end of pipe First attach the four...

Страница 44: ...w well is recommended with adequate and proper drainage as per local codes Leave 2 clearance below snorkel to prevent water from entering the Snorkel Termination Do not enclose the Snorkel within a wa...

Страница 45: ...VENTING AIR INTAKE PLATE ADJUSTMENT NOTE Unit comes preset for vertical venting under 15 feet Follow these instructions when venting exceeds 15 feet vertical 1 Locate the 3 x 1 4 hex screws and using...

Страница 46: ...f pitch card Slide a Roof Flashing suitable to your roof slope over the vent Place the edge of the flashing plate that will be on the higher part of the roof slope under the shingles Both the sides an...

Страница 47: ...anded to 20 expanded ZDVFS Firestop Spacer required when passing through floors and ceilings ZDVVOS Offset Support Strapping needed to support pipe when bending FDVE45 7 diameter x 45 Black Elbow FDVE...

Страница 48: ...lve Nova LP Hi Lo 0820651 1001 P634SI Valve Nova NG Hi Lo 0820652 1001 P713SI Pilot Burner LP 199 713 TC SIT 1001 P714SI Pilot Burner NG 199 714 TC SIT 1000 214 Piezo Igniter 1244 17 Mark21 1001 P144S...

Страница 49: ...ains Horizontal Vent Termination Zero Clearance Wall Sleeve Black Wall Trim Ring 7 Dia Black Pipe 24 Length 7 Dia Black Pipe 48 Length 7 90 Degree Black Elbow 4 Flex 48 Unexpanded 96 Expanded 7 Black...

Страница 50: ...eep toddlers young children and other at risk individuals out of the room and away from hot surfaces Do not leave the fireplace remote control where it is accessible to children Termination Cap Safety...

Страница 51: ...hemicals other than in a normal residential environment c damages caused by any unauthorized alteration or repair of the unit affecting its stability or performance d damages caused by improper matchi...

Отзывы: