Gas Line Installation

 

 

This gas appliance should be installed by a qualified installer in accordance with local building codes and with current CAN/CGA - 
B149.1 or .2 installation codes for Gas Burning appliances and equipment in Canada and the National Fuel Gas Code ANSI Z223 in 
the U.S.A. 
1.  The gas pipeline can be brought in through 
the back or bottom of the unit. 
2.  The gas control inlet is 3/8” NPT. Typical 
installation layout for rigid pipe is shown at right. 
3.  When using copper or flex connector, use 
only approved fittings. Always provide a union 
so that gas line can be easily disconnected for 
burner or fan servicing. See gas specification for 
pressure details and ratings. 
4.  When a vertical section of gas pipe is 
required for the installation, a condensation trap 
is needed. See CAN/CGA-B149.1 or .2 for code 
details. 
5.  For natural gas, a minimum of 3/8” iron pipe 
with gas minimum pressure of 4.5” w.c. must be 
used for supply from the gas meter. Consult with the local gas utility if any questions arise concerning pipe sizes. 
6.  A 1/8” NPT plugged tappings are accessible for test gauge connection both on the inlet and outlet of the gas valve. 
7.  Turn the gas supply ON and check for leaks. DO NOT USE OPEN FLAME FOR THIS PURPOSE. Use an approved leak testing 
solution. 
8.  The appliance and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure 
testing of that system at test pressures in excess of 1/2 PSIG (3.5 KPa). 
9.  The appliance must be isolated from the gas supply piping system by closing its individual shutoff valve during any pressure 
testing of the gas sup- ply piping system at test pressures equal to or less than 1/2 PSIG (3.5 KPa). 

 
 

 

 

 

 
 
 
 

 

Gas Specifications 

MODELS 

FDV200SN 

FDV200SNE 

FDV200SNE2 

FDV200SLP 

FDV200SLPE 

FDV200SLPE2 

Fuel 

Natural 

Natural 

Propane 

Propane 

Gas Control 

Millivolt 

IPI 

Millivolt 

IPI 

Maximum 

28,500 

28,500 

26,000 

26,000 

Low 

19,500 

19,500 

20,000 

20,000 

Orifice Size 

(0-4500ft) 

#35 

#35 

1/16” 

1/16” 

Air Shutter 

3/8

” 

3/8

” 

Fully Open 

Fully Open 

Gas Inlet Size S.I.T. 820 Nova, 3/8” NPT 

Gas Supply Pressure 

Minimum 

Normal 

Maximum 

   

Natural Gas 

5.5” 

7” 

9” 

   

Propane 

11” 

11” 

12” 

   

Manifold Pressure 

Natural Gas 

Propane 

   

Manifold Pressure High 

3.5 IN. W.C./.87 KPa 

10 IN. W.C./2.61 KPa 

   

Manifold Pressure Low 

1.6 IN. W.C./.40 KPa 

6.3 IN. W.C./1.57 KPa 

   

 

 

 

3/8” UNION 

1/2” X 3/8” SHUTOFF VALVE 

3/8” NIPPLE 

1/2” GAS SUPPLY 

NOTE:

 

The gas line connection may be made of 1/2” rigid pipe or an 

Approved Kingsman Flex Connector, such as FP15GC

Since some municipalities have additional local codes, it is always best to consult your local authorities and the current CAN/CGA - 

B149.1 or .2 installation code in Canada or the National Fuel Gas code ANSI Z223.1 in the U.S.A 

 

Important: Always  check  for  gas  leaks  with  a 
soap  and water  solution.  Do not use  open flame 
for leak  testing.

 

For the state of Massachusetts a T-handle gas 
shut-off valve  must be used on a gas 
appliance.  This T-handle gas shut-off valve 
must be listed and approved by the state of 
Massachusetts.  This is in reference to the state 
of Massachusetts state code CMR238. 

GAS VALVE 

GAS FLOW 

Shutoff  valves  installed  in  tubing  systems 
shall  be  rigidly  and  securely  supported 
independently of the tubing.

 

18

Содержание FDV200S

Страница 1: ...y or the gas supplier Installation Instructions This appliance may be installed in an aftermarket permanently located manufactured home USA only or mobile home where not prohibited by local codes This...

Страница 2: ...t Part B series 0190XYZ 21 Gas Conversion for Modulator PART C 22 Millivolt System Lighting and Burner Control 23 Electronic Ignition Lighting Instructions 24 Troubleshooting the Gas Control System 25...

Страница 3: ...PARTS LIST FDV200S Parts List 48 49 WARRANTY Glass Safety Termination Cap Safety 50 Limited Lifetime Warranty 51 3...

Страница 4: ...Top Hooks into Top Slots 3 Engage Bottom Hooks into Bottom Slots Top Slot Bottom Hook Top Hook To remove Safety Screen Wait Until Fireplace is Completely Cool and reverse these steps Bottom Hook Top H...

Страница 5: ...sounds produced by a furnace or heating duct This noise does not affect the operation or longevity of your fireplace It is also normal for the fan to make some noise when it comes on This noise can be...

Страница 6: ...condition of vent and vent terminal for sooting or obstruction and correct if present 6 Vacuum and clean any debris in the firebox that is not supposed to be there 7 Test and measure the flame failure...

Страница 7: ...due to excessive lint from carpeting bedding material et cetera It is imperative that control compartments burners and circulating air passageways of the appliance be kept clean Make sure that the ga...

Страница 8: ...ication plate shall be mounted at the exterior of the building four feet directly above the location of vent terminal The plate shall be of sufficient size to be easily read from a distance of eight f...

Страница 9: ...IN MANUFACTURED MOBILE HOMES IN CANADA Please follow the current ANSI NFPA 70 National Electrical Code in the USA and CAN CSA C22 1 Canadian National Electrical Code in Canada An appliance must be gro...

Страница 10: ...rotection being required This unit has been tested in an Alcove Minimum Dimensions of Alcove are as follows Depth 30 Height 55 5 Width 52 5 THE FOLLOWING MINIMUM DISTANCES TO COMBUSTIBLES MUST BE OBSE...

Страница 11: ...Remote Receiver Battery Backup Remote Receiver Battery Backup Piezo Igniter Piezo Igniter Valve Valve Valve Battery Backup Battery Backup Fan Speed Control Fan Speed Control Fan Speed Control Proflame...

Страница 12: ...y remove the Rear Tabs from the unit To Install Component Cover Hook the Rear Tabs over the back of the Component Tray Next attach front of Component Cover with 2 DT screws WARNING Wait until unit is...

Страница 13: ...FDV200S Optional Fan Installation Part F45FK 13...

Страница 14: ...rounding plug for your protection against shock hazard and should be plugged directly into a properly grounded three prong receptacle Label all wires prior to disconnection when servicing controls Wir...

Страница 15: ...oval diagram 2 Place Back Brick Panel up to rear of firebox leaving bottom of panel slightly forward for support 3 Remove left and right Brick Clips using a 1 4 nut driver Do not discard Brick Clips 4...

Страница 16: ...Tabs 3A and 3B Do not place Log 3 on top of Locating Tabs Step 4 Place Log 4 onto notched areas of Log 1 and Log 3 Step 5 Place Log 5 up against the 2nd Grate Bar from the left as shown Step 6 Place G...

Страница 17: ...Door and Glass Information FDV200S Safety Screen Frame Assembly Glass Front Door Assembly Screw Screw 17...

Страница 18: ...olated from the gas supply piping system by closing its individual shutoff valve during any pressure testing of the gas sup ply piping system at test pressures equal to or less than 1 2 PSIG 3 5 KPa G...

Страница 19: ...ription Pilot Orifice Burner Orifice Brass 1000 255 Brass Nipple Air Shutter Hi Lo Regulator 200DV CKLP FDV200SLP Propane Conversion Millivolt 1001 P167SI 30 977 167 1 16 1000 253 closed Full Open 100...

Страница 20: ...to convert the valve from one type of fuel to the other Step 8 Check for gas leaks around the pilot burner tube and face of valve Step 9 Attach conversion label to label plate on bottom of unit writi...

Страница 21: ...njector near the top Propane injectors have a groove machined around their circumference near the top while NG injectors do not have a groove fig 4 Refer to the Appliance Manufacturer s instruction sh...

Страница 22: ...Gas Conversion for Modulator PART C 22...

Страница 23: ...ly the pilot burner located on the rear center left hand side of the main burner If a flame has appeared then continue to depress the control knob for 20 seconds If the flame did not appear then conti...

Страница 24: ...all electric power to the appliance 4 This appliance is equipped with an ignition device which automatically lights the pilot Do not try to light the pilot by hand 5 Wait five 5 minutes to clear out...

Страница 25: ...as valve Should read 325 millivolts minimum while holding valve knob depressed in pilot position and wall switch off Replace faulty generator if reading is below specified minimum Plugged burner orifi...

Страница 26: ...13 1002 P033SI TC Pilot Burner IPI Assembled NG 199 033 14 1002 P047SI TC Pilot Burner IPI Assembled LP 199 047 15 1001 P166SI TC Orifice Pilot NG 977 166 62 IPI 16 1001 P168SI TC Orifice Pilot LP 977...

Страница 27: ...s required The following sequence must be followed to reset the PF2 Module Press the Red SW1 button until you hear three beeps Within 10 seconds press the SW1 button again until you hear it beep The P...

Страница 28: ...the main burner has been cycled ON OFF and the pilot is also out follow the procedures described in this manual to light the pilot To switch from IPI to CPI Mode 1 Turn the fireplace OFF using the ON...

Страница 29: ...Proflame 2 Remote Control 29...

Страница 30: ...Note When Smart Thermostat is activated manual flame height adjustment is disabled Note This function is only available in Room Thermostat or Smart Thermostat Control Mode Halogen lights only 30...

Страница 31: ...iring Diagram For use with all Kingsman manufactured IPI Proflame 2 models for all types of gas noted on rating plate Supply 120VAC 60Hz 3A 6 volts battery backup Pour utilisation avec tous les mod le...

Страница 32: ...ck This component permits the IPI system to operate without the need for an external AC Adapter power source The advantage to using the battery backup is that in the case of a power failure the applia...

Страница 33: ...hat the room thermostat is ON and the set temperature is now displayed To adjust the set temperature press the Up or Down Arrow Keys until the desired set temperature is displayed on the LCD screen of...

Страница 34: ...P 977 168 35 IPI 11 1002 P012SI IPI Stepper Kit LP 907 012 12 1002 P013SI IPI Stepper Kit NG 907 013 13 1002 P014SI IPI Reg Kit LP Hi Lo 907 014 14 1002 P016SI IPI Reg Kit NG Hi Lo 907 016 15 1002 P01...

Страница 35: ...Configuration 1 Basic manual HI LO and manual ON OFF capabilities 35...

Страница 36: ...s with remote HI LO capabilities a modulating servo is required to be installed on the valve The connectors to this servo must be connected to the Remote Harness as shown SCHEMATIC PICTURE NOTE Fan Op...

Страница 37: ...er Adapter P N 1002 P850si The Remote Receiver IPI or Millivolt system can be powered by the AC Adapter This is advantageous if you do not want to use batteries Simply connect the AC Adapter into the...

Страница 38: ...lities Refer to the fan installation removal section for fan installation NOTE Fan Option is not available on some models of fireplace Check with your dealer NOTE This Configuration is not available o...

Страница 39: ...3 m horizontally L Clearance above paved sidewalk or paved driveway located on public property 7 ft 2 13 m Notes 2 M Clearance under veranda porch deck or balcony 12 in 30 cm 12 in 30 cm N Where a ve...

Страница 40: ...g in bend or before and after See Fig 1 Horizontal runs require support metal straps every 2 feet In offset installation support straps should be used to stabilize pipe Expand 4 and 7 flex pipe to the...

Страница 41: ...installed in either the horizontal or vertical runs Minimum clearances on venting 4 to top of elbow 2 1 2 from top of horizontal pipes 1 on all other existing pipes Only trim kit s supplied by the ma...

Страница 42: ...m and the number of elbows required 2 Use the Venting Chart to determine the maximum horizontal distance allowed Note For each 45 elbow installed in the horizontal run the length of the horizontal run...

Страница 43: ...he pipe extends properly through wall thimble and into vent termination 7 Before joining pipes to fireplace flue apply a bead of high temperature sealant Mill Pac to end of pipe First attach the four...

Страница 44: ...w well is recommended with adequate and proper drainage as per local codes Leave 2 clearance below snorkel to prevent water from entering the Snorkel Termination Do not enclose the Snorkel within a wa...

Страница 45: ...VENTING AIR INTAKE PLATE ADJUSTMENT NOTE Unit comes preset for vertical venting under 15 feet Follow these instructions when venting exceeds 15 feet vertical 1 Locate the 3 x 1 4 hex screws and using...

Страница 46: ...f pitch card Slide a Roof Flashing suitable to your roof slope over the vent Place the edge of the flashing plate that will be on the higher part of the roof slope under the shingles Both the sides an...

Страница 47: ...anded to 20 expanded ZDVFS Firestop Spacer required when passing through floors and ceilings ZDVVOS Offset Support Strapping needed to support pipe when bending FDVE45 7 diameter x 45 Black Elbow FDVE...

Страница 48: ...lve Nova LP Hi Lo 0820651 1001 P634SI Valve Nova NG Hi Lo 0820652 1001 P713SI Pilot Burner LP 199 713 TC SIT 1001 P714SI Pilot Burner NG 199 714 TC SIT 1000 214 Piezo Igniter 1244 17 Mark21 1001 P144S...

Страница 49: ...ains Horizontal Vent Termination Zero Clearance Wall Sleeve Black Wall Trim Ring 7 Dia Black Pipe 24 Length 7 Dia Black Pipe 48 Length 7 90 Degree Black Elbow 4 Flex 48 Unexpanded 96 Expanded 7 Black...

Страница 50: ...eep toddlers young children and other at risk individuals out of the room and away from hot surfaces Do not leave the fireplace remote control where it is accessible to children Termination Cap Safety...

Страница 51: ...hemicals other than in a normal residential environment c damages caused by any unauthorized alteration or repair of the unit affecting its stability or performance d damages caused by improper matchi...

Отзывы: