FDV200S
Venting Routes and Components
Since it is very important that the vent system maintain its balance between the combustion air intake and the flue gas
exhaust, certain limitations as to vent configurations apply and must be adhered to.
See venting chart for total horizontal and vertical runs.
For every 90° elbow after the first 90° elbow the horizontal run must be reduced by 36”.
For every 45° elbow after the first 90° elbow the horizontal run must be reduced by 18”.
This does not apply if the 45° elbows are installed on the vertical part of the vent system. 45° elbows can be
installed in either the horizontal or vertical runs.
Minimum clearances on venting (4" to top of elbow), (2-1/2" from top of horizontal pipes), (1" on all other existing pipes).
Only trim kit(s) supplied by the manufacturer shall be used in the installation of this appliance. Draft Relief Openings must
not be covered or blocked.
IMPORTANT: Always locate the fireplace in such a way that a minimum of offsets and/or horizontal runs are required.
1/4” vertical rise is required for every 12” horizontal run.
The minimum allowable configuration is
4-1/2 feet vertical with unit 4” from wall.
2
Feet
20
Feet
The maximum horizontal vent run with one 90°
elbow attached is 20 feet with 7 feet vertical.
The maximum vertical rise is 40 feet.
Support Straps
every 3 Feet
3”
4-1/2
Feet
7
Feet
40 Feet
Max
41
Содержание FDV200S
Страница 13: ...FDV200S Optional Fan Installation Part F45FK 13...
Страница 17: ...Door and Glass Information FDV200S Safety Screen Frame Assembly Glass Front Door Assembly Screw Screw 17...
Страница 22: ...Gas Conversion for Modulator PART C 22...
Страница 29: ...Proflame 2 Remote Control 29...
Страница 35: ...Configuration 1 Basic manual HI LO and manual ON OFF capabilities 35...