background image

power switch to OFF position. 

 1 

SAVE THESE INSTRUCTIONS 

OPERATION 

KING ELECTRIC MFG CO · 9131 10TH AVENUE SOUTH · SEATTLE, WA 98108 · PH:206 762 0400 · FAX: 206 763 7738 · www.king-electric.com 

OPERATION 

Operation 

1. Position the fan heater so that it stands upright on a firm, 
level surface (When used as a portable) and at a safe distance 
from wet locations and flammable objects. 

2. Connect the fan heater to the proper electrical power. See 
grounding instructions (Figure 2) 

3. Set the thermostat dial to the maximum temperature. 

4. Once the room reaches the desired temperature, turn the 
thermostat dial back until heating element turns off. The heater 
will cycle automatically around this preset temperature. To 
increase temperature, turn the thermostat knob clockwise. To 
lower temperature, turn the thermostat counterclockwise. 

5. LOW setting on thermostat does not prevent heater from 
turning ON. Turn power switch to OFF or unplug from wall to 
prevent heater from turning ON. Before unplugging heater, turn       

 

IMPORTANT: This heater has a built-in Fan Delay designed 
to exhaust heat from the unit until the elements are cool 

(Cool Down Cycle). This improves energy efficiency. The fan 
may cycle on/off for a few minutes after the thermostat is set 
to the LOW position or power switch is set to OFF. This is normal 
and required to cool down heater and also prevent the safety 
limit from nuisance tripping.

 

HOW TO RESET THE HEATER (SURESTOP

 SAFTEY LIMIT) 

This heater is equipped with an internal safety limiting          
thermostat and overheat protection circuit. 

 

If SAFTEY LIMIT light illuminates, an abnormal condition has 
turned off the heating elements. TO RESET, WAIT 10 
MINUTES to allow the heater to cool down, then insert a 
small screw driver tip into the hole on the front of the heat-
er marked “LIMIT RESET” and push firmly until you hear a 
click.

 

Thermostat Instructions 

- At first, set the thermostat to “+” and let the heater operate 
with full power input. When the room temperature reaches the 
required value, turn the thermostat to the left until it switches 
off. 

- The thermostat will then switch on and off automatically to 
control the room temperature according to the preset value and 
keep the room temperature constant. 

- When using the heater for the first time, you may notice a 
slight emission of smoke. This is quite normal and it stops after 
a short time. The heating element is made of steel and was 
coated with a layer of protective oil during production. The 
smoke is caused by the leftover oil as it is heated. 

Grounding Instructions 

- This heater is for use on 240 (or 208) volts. The cord has a plug 
as shown in figure 2 (below). No adapter is available for this 
blade configuration, and none should be used. The type outlet is 
a 240 (or 208) volt grounding outlet. When properly installed, it 
provides a ground connection through the cord to the heater to 
protect the operator from electric shock. 

- Be sure that the electrical receptacle is of the configuration 
and capacity appropriate for the heater. 

DANGER 

!

 

!

 

ELECTRIC SHOCK OR FIRE HAZARD 

READ ALL WIRE SIZING, VOLTAGE REQUIREMENTS AND 

SAFETY DATA TO AVOID PROPERTY DAMAGE AND 

SPECIFICATIONS 

BTU 

13,000B 

Watts 

3,750W 

Heating Area (ft2)  450 ft2 
Power (Volts) 

240V~60Hz 

Amps 

16A 

Heat Settings 1 

On/Off 

Heat Settings 2 

Thermostat 

Figure 2 

PLUG TYPE 
20 amp 240 V 
NEMA #6-20P 

Отзывы: