OPERATION: Disassembly of the hopper, feeder ring and tablet guide
•
Begin by removing the
HOPPER LID
(if fitted) and proceed to loosen the two
HAND
KNOBS
locate at the rear of the
HOPPER MOUNT
. Once complete the hopper assembly
may be removed.
•
Proceed to untighten the
CLAMP
located in the centre of the
FEEDER RING
. Once remove
this will allow the operator to remove the
FEEDER RING
.
•
Finally withdraw the
TABLET GUIDE
from the top of the machine.
Hopper
Clamp
Tablet Guide
Feeder Ring
Vibrator Shroud
Hopper Lid
Hand Knob
Hopper Mount