ORIGINAL INSTRUCTIONS
Model:
Dispenser Rx
Serial Number:
5780/14
Instructions Manual Dispenser Rx Tablet and Capsule Counting Machine Edition v2.1
24
OPERATION: Best Practice for Feeding (
To Maintain Counting Accuracy
)
Note : Shown with Hopper removed for clarity.
•
It is very important to achieve an even product stream in order to avoid tablets and
capsules riding or piggybacking over one another when feeding towards the
FEEDER
RING EXIT
. If two tablets or capsules exit at the same time this may cause a miscount
resulting in an overcount.
•
A good product stream is evident when tablets or capsules flow in a single file when exiting
the hopper and orientate and align themselves when feeding towards the feeder ring exit.
•
It is equally important that the centre of the
FEEDER RING
is not flooded or starved of
product but an even balance is achieved. Different product types, sizes and shapes will
handle differently so it is important to record the machines settings for future use.
•
Certain products such as capsules and small tablets may require an additional
CONTROL
CLIP
fitted to the
FEEDER RING OUTLET
in order to restrict the outlet size. This will
ensure that any excess tablets or capsules on the
EXIT FLIGHT
fall back into the
FEEDER
RING CENTRE
which will result in a controlled flow and allows a higher feed rate without
product overcrowding or piggybacking.
Tablet Stream
Exit Flight
Feeder Ring
Feeder Ring
Exit
Feeder Ring
Outlet
Feeder Ring Centre