Page 27 of 57
King Pigeon Hi-Tech. Co., Ltd.
Ver 3.0
GSM/SMS/GPRS/3G/4G
Cellular IoT M2M RTU
Current Value:
Stands for input’s current value of the transducers.
Threshold High:
The high value(reached) need to alarm; Example: set 50Celsius degree to alert.
Threshold Low:
The low value(reached) need to alarm; Example: set -30Celsius degree to alert.
Recovery Alarm:
Tick it stands for when the analog input recovery, will send SMS to the
authorized numbers.
Siren:
Tick it stands for while this input triggering, the DO that output type was setup as
Siren
will execute the its output parameters.
24Hr:
Tick it stands for no matter the RTU is in Arm or Disarmed mode, this input triggered
will alarm.
Reminder:1) According to the output type of the transmitter, set the correct mA and V type on the DIP
switch of the device, please see 2.3 Mode Selection and 2.3 AI Wiring Diagram; 2) The same
input type should be set in the configuration software; 3) The maximum and minimum range
of the analog quantity, please refer to the transmitter technical specification to fill in, or
consult the transmitter manufacturer
Timer Settings
This page is for setup hour timer and periodically timer, it is useful for scheduling when to execute what
action automatically or it with repeat this action according to the interval time. Total can program 10
scheduling events. Tick it stands for enable this timer event:
Reminder:
When GPRS/3G/4G data transmission protocol is King Pigeon IoT RTU Protocol, the periodically auto upload
default enable and upload every 5 minutes.
Tick stands for enable this timer function, otherwise is disable.
Hour+Minute:
Stands for what day and at what time does the RTU should start to
execute the action and interval how many seconds then repeat to execute the action.
Interval:
Stands for interval how many seconds does the RTU should repeat to execute the action.
If setup it as 0, then this event will not be repeated.
Action:
Stands for what action does the RTU should to execute at the specified time.