GSM SMS Alarm & Dialer
GSM SOS Call System!
G S M A l a r m S y s t e m .
11
Xx= ON or xx=OFF. Default is off.
Xx=ON, stands for when armed the K2 by remote control successful, the siren will sound 2seconds. If
setup successful, will return
Set Ok.
Xx=OFF, stands for when armed the K2 by remote control successful, the siren will NOT sound. If setup
successful, will return
Set Ok.
Tips:
if armed or disarmed by phone call or SMS, the siren will not make sounds to response.
6.16 Setup Automatically report Status function
XX=00~99, unit is hour, stands for the interval time to report the K2 status to the first SMS Alert Number.
default is 00, means disable report function. If no SMS number, this function will be invalid. The return
SMS is the same as by
8.4 Inquiry Status and GSM Module IMEI Code
6.17 Reset the K2 Panel to Factory Default
The K2 Panel can be reset to the factory default by following operation: Switch off the K2 Panel, then
press the UP and Down Button at the same time(See below), Switch on the K2 Panel, about 3Seconds
later, the K2 Panel will make sounds to alert, then loose the RESET button, means the reset operation
successful.
And please restart the K2 Panel again.
After this operation, all the registered wireless detectors and wireless panic buttons and Remote Controls
will be removed from the K2 Panel, and all of the settings will be reset to the factory default.
7. Zone Settings
7.1
Registering the wireless sensor, remote control, wireless buttons to the K2
Tips:
a. After registered the wireless sensor, remote control or wireless buttons, must restart the K2;
b. After your registered a wireless sensor or remote control or button to the position, must switch back the DIP to OFF Side
except the 1
st
position.
c. The package wireless detectors registered in the K2 already, no need to relearn it again.
The K2 is learning code, more safe and easy to add new wireless remote keys and wireless detectors,
it supports 3 remote controls and 16 Wireless Zones, it can accept one learning code wireless detector
in each zone, and accept unlimited PT2262/2272 fixed code wireless detectors in each zone. The K2
integrated verity programmable zone attributes, includes Away(normal), At House or Stay, Entrance
Zone, 24 Hours Sound Zone, 24 Hours Silent Zone, Local Zone, SOS Zone, Door Bell Zone. The SMS
Alarm Content of each zone is programmable by user through SMS Commands.
Please follow below step by step to learning the wireless detectors or remote controls or wireless
buttons to the expected zones.
pwd+T+xx+#
#