GSM SMS Alarm & Dialer
GSM SOS Call System!
G S M A l a r m S y s t e m .
10
6.11 Setup the Arm Delay Time(Default is 30seconds)
If setup successful, will return
Armed Delay + xx + Seconds
G
is the identification character of this command.
Xxx=00~99, unit is second, 2digits. Default is 30 seconds.
Tips:
1) Only the zone attribute code setup as 1,2,3 will delay to enter into Arm mode when Arm the K2;
2) If Armed the K2 by remote control, after press the Armed Button, and press its SOS button within 2 Seconds the K2 will
enter into Armed Mode immediately, will not delay.
6.12 Enable to Alert the first Authorized Number when other number armed or disarmed the
K2(Default is Disable)
If setup successful, will return
Send Operation Code to 1
st
Number
H
is the identification character of this command.
Tips:
If enable this function, when the Authorized Number that Function 2 Code=1 (can dial in to change the status from
Stay to Arm) call in the K2, will send SMS to the 1st Authorized Number. If any other number armed or disarmed the K2, it
will send SMS to the 1st Authorized number. The SMS content is
Armed By + Telephone number
or
Disarmed by
+Telephone number.
Disable this function SMS Command is
pwd+J+#
6.13 Required the K2 callback
If send successful, the K2 will call back the user immediately. It is special for the Authorized Number that
Function 2 Code=1 (can dial in to change the status from Stay to Arm) to listen on-site.
6.14 Setup External Power Status Alert Feature(Default is 30 minutes)
If send successful, will return SMS.
M
is the identification character of this command.
Xx= 00~99. Default is 30. Unit is minute
Xx=00, stands for when external AC Power goes off will send SMS
AC Power Goes off
to all authorized
numbers or send SMS
AC Power Goes ON
when AC Power goes on. If setup successful, will return
AC
Power Goes off Send SMS Immediately.
Xx=01~99, stands for when external AC Power goes off more than 01~99 minutes will send SMS
AC
Power Goes off 01~99minutes
to all authorized numbers or send SMS
AC Power Goes ON
when AC
Power goes on.
If the AC Power goes off less than 01~99 minutes then goes on, will not send SMS. If
setup successful, will return
AC Power Goes off Send SMS After 01~99minutes.
6.15 Setup Siren Response Feature to Arm Operation
If send successful, will return SMS.
pwd+G+xx+#
#
pwd+H+#
#
pwd+K+#
#
pwd+M+xx+#
#
pwd+xx+#
#