6
5.4 Switching on/off the K2 Panel
After finished all of the connections, please plus the AC/DC Adaptor to external AC Power socket, and
switch the PSW Switch to ON side to switch on the K2 Panel. See abovementioned.
5.5 Amounting the K2 Panel
The K2 Panel should be installed in a place where the intruders cannot discover it. And the GSM Signal
covered well. Also, the user can see the LED easily to know what happened and what is the status of the
K2 Panel.
6. Settings
The K2 is an advanced multifunctional programmable controller. The user can program it by SMS
Commands for various application requirements.
Notice:
1. The default Password is
1234
.
2. All the settings are through SMS commands, please edit the below SMS commands in your cell
phone, then send to the K2. (Tips: The K2 cannot support PIN Code Protected SIMCard. Please
ensure you have disabled the PIN Code of the SIMCard, otherwise can not register GSM
Network successful.)
3. You can program the GSM Alarm & Dialer K2 with SMS commands using your phone. It is safe
to do so because in addition to the fact that other people may not know the number of the SIM
inserted in it, we also use a Password that makes it impossible for anybody, who doesn't know it,
to access the system by chance.
4. Remember that commands must be
CAPITAL LETTERS
. It is PWD not pwd, CAP not Cap etc.
Don't add spaces or any other character.
5. The
pwd
in the commands is means the password, when you use it, please in stand of it by the
digital number.
6. While setup phone numbers, please try to plus the country code or remove country code. E.g.:
008613500001111, or 13500001111.
7. Please write down the setting list in a paper for review in further, please see the affix table at the
last page, and tear down from this instruction for review.
8. If the command is incorrect, the K2 will return:
SMS Format Error, Please check Caps Lock in
Command!
Or other warning message. So please check the Command, or check the input is in
ENGLISH INPUT METHOD and CAPS LOCK. If the password incorrect will not return any SMS.
9. When power on the K2, will alert Di sound once, and all zones
’ LED will turn on once, then the
LED which registered wireless sensor already will turn on once more.
10. If more than 2 minutes the GSM Simcard still register the GSM Network failure, the buzzer will
make
“Di” once, and every 10 seconds detects the SIMCARD registering status and failure will
alert by
“Di” once till restart or switch off.
11. If the communication between the MCU and GSM Module failure, the buzzer will make
“DiDi”
twice to warning every 10 seconds till switch off or restart.
12. If detect the K2 hasn
’t inserted SIMCard, the Buzzer will only make once di sound to alert. And
will not detect the SIMCard again.