manualshive.com logo in svg
background image

Main screen5:PD communication monitor 
screen

Menu button

Switch between monitor or sniff mode

Left|Right button

Switch to other main screen

Monitor

Monitor mode(default) only monitor data 
packets on CC wires, 

if CC wires doesn’t 

connect will cause 

Intermittent power failure

Sniffer

Sniff mode , automatic sent handshake packet 
when press button, 

can change SRC Fixed 

Supply PDO

CC1、CC2

The CC wire current used for communication, 
automatic change

Source Cap

Source or Sink 

packet of PD communication 

protocol

Request

Upper layer requests to change to a different 
power supply from Source. 
We send a new REQUEST message to the 
Source and the upper layer can start using the 
new power supply

5.050V 3.001A

CC1

5.00V 3.0A
9.00V 3.0A
15.0V 2.0A

Monitor

Source Cap

5.050V 3.001A

CC2

5.00V 3.0A
9.00V 3.0A
15.0V 2.0A
20.0V 1.5A

Sniffer

Request
2.00/2.00A

Main screen6:About Logo Help information

Menu button

click enter 

System Setting 

screen

Left|Right button

Switch to other main screen

Website

www.chargerlab.com

My blog website ,can 

obtain more help information

Copyright (C) 2017

LYSstudio Vision 1.0
www.chargerlab.com

System setting1:Screen parameters

Menu button

Switch to next screen

Left|Right button

①Change screen brightness level ②Open 
screen saver mode ③Standby time

Brightness

Screen brightness, step 5 range from 0 to 100

Saver

Screen saver mode

Sleep

Standby time, for example enter standby 
mode 1 hours later, still measure

Screen

Brightness             60

Saver

OFF

Sleep  1 hours

System setting3:Calibration parameters

Menu button

Switch to next screen

Left|Right button

①Adjust reference voltage  ②One key 
calibrate ③Manual adjust gain

VBUS

Voltage measured

VREF

Reference voltage input , need very precise 
voltage source

AUTO CAL 

Press right/+ for one key calibrate

ZERO

Press right/+ for one key set current to 0

AMPS

Current of output load

Calibration

VBUS

10.0000

VREF

10.0002

AUTO CAL                 R
GAIN

1.00018

Calibration

ZERO

0.0000        R

IREF

2.4999

AUTO CAL                 R
GAIN

1.00001

System setting3:FactoryReset parameters

Menu button

Switch to next screen

Left|Right button

Press right/+ restore reference data and 
system settings to factory preset

FactoryReset

Warning...

Erase all data           R

Содержание POWER-Z

Страница 1: ...Manual V1 0 2017 5 ...

Страница 2: ...USBA Micro USB TYPE C Long term Stability 50ppm 1000Hrs Dimension Length X Width X High 62X24X12 Weight 20g Power Supply Type HID port 5V other port self pickup electricity 3 7 24V Maximum input voltage except HID port 24V Working current 4 15mA Standby 3mA 5V QC2 0 QC3 0 Test Sniffing Support Power Delivery Test sniffing Support Pro version support PD2 0 protocol packet capture Typical interface ...

Страница 3: ... data management calibrate firmware update no driver needed plug and play Pro version can test PD2 0 protocol monitor the data on cc wires and decode display For example can capture the 10 packets of Mac s handshake decode and display each packet in characters suitable for development QC Protocol Test Sniff the USB interface of power adapter whether support QC2 0 3 0 or not PD Protocol Test Intern...

Страница 4: ...creen3 4 Run rules Menu button Switch next menu option Left Right button Open Close Change current threshold Auto Run Open this feature will automatic measure when load current exceed threshold preset such as 0 1A measurement don t create a new channel will stay the channel which Gauge choosed Auto Stop This parameter must small than value of Auto Run will stop measurement when load current less t...

Страница 5: ...ght button Switch to other main screen Curve speed Total 4 levels maximum 100SPS sample speed Curve type Can only display voltage or current decrease display speed Main screen4 Micro oscilloscope D D Curve Menu button Test QC2 0 3 0 protocol Left Right button Switch to other screen HVDCP Charge protocol information Sniff mode Current support QC2 0 Q3 0 will support more protocols in future 9 056V ...

Страница 6: ...een Website www chargerlab com My blog website can obtain more help information Copyright C 2017 LYSstudio Vision 1 0 www chargerlab com System setting1 Screen parameters Menu button Switch to next screen Left Right button Change screen brightness level Open screen saver mode Standby time Brightness Screen brightness step 5 range from 0 to 100 Saver Screen saver mode Sleep Standby time for example...

Страница 7: ...inimum values in the window Vp p Ip p Curve will scroll from right to left according to sample time The figure below displays noise of a standard 2 50000A high fidelity current source the noise actually is the interior noise of instrument in 100SPS high speed acquisition Could get better performance if set sample speed to 10SPS ...

Страница 8: ...roduce Offline data fetch and generate curve Cumulative display curve The time axis of curve remain 0 the curve will continuous compress Application case The figure below displays charge curve of a power bank ...

Отзывы: