manualshive.com logo in svg
background image

Kvaser U100S-X3 User’s Guide

Copyright 2020-2022 Kvaser AB, Mölndal, Sweden
https://www.kvaser.com

Printed Sunday 29

th

May, 2022

We believe that the information contained herein was accurate in all respects at the time of printing.
Kvaser AB cannot, however, assume any responsibility for errors or omissions in this text. Also note
that the information in this document is subject to change without notice and should not be construed
as a commitment by Kvaser AB.

Содержание U100S-X3

Страница 1: ... believe that the information contained herein was accurate in all respects at the time of printing Kvaser AB cannot however assume any responsibility for errors or omissions in this text Also note that the information in this document is subject to change without notice and should not be construed as a commitment by Kvaser AB ...

Страница 2: ...Kvaser U100S X3 User s Guide 2 24 This page is intentionally left blank Kvaser AB Mölndal Sweden www kvaser com ...

Страница 3: ... supply 10 3 7 LED Indicators 11 3 8 Interface mode 12 3 9 The t programming language 13 3 10 Restrictions in t functionality 14 3 11 Updating the firmware 16 3 12 Technical data 17 4 Troubleshooting 18 5 Safety Instructions 19 5 1 Intended Use 19 5 2 Usage Warning 19 6 Disposal and Recycling Information 20 7 Legal Acknowledgements 21 7 1 EU Regulatory Compliance 21 7 2 FCC Regulatory Compliance 2...

Страница 4: ...About this manual This manual is intended for Kvaser U100S X3 users This document contains a description of the hardware s properties and general instructions for connecting the device to a computer Kvaser AB Mölndal Sweden www kvaser com ...

Страница 5: ...s with a high timestamp precision and is compatible with applications that use Kvaser s CANlib This guide applies to Kvaser U100S X3 devices using at least firmware and driver versions listed in Table 1 For minimum compatible firmware and driver versions of Kvaser U100S X3 see Table 7 on Page 16 Device Product Number Firmware Driver Windows Linux Kvaser U100S X3 73 30130 01274 5 v3 25 v5 36 kcany ...

Страница 6: ...made of glass fibre reinforced polyamide overmolded with TPE Intuitive LED UI Reinforced galvanic isolation design validated with 5000 VAC rms applied for 60 s Industrial grade temperature range 40 C to 85 C 20 000 msg s each timestamped with a resolution of 1 µs Kvaser MagiSync automatic time synchronization see Section 3 3 Kvaser MagiSync on Page 8 for more details Fully compatible with applicat...

Страница 7: ...ctions on how to update the firmware see Section 3 11 Updating the firmware on Page 16 The latest version of the driver and firmware can be downloaded from www kvaser com download The firmware is downloaded and installed directly on the Kvaser U100S X3 and the driver is installed on the host computer After the driver has been installed on the host computer the firmware may then be downloaded and i...

Страница 8: ...ces connected to one host computer Since each host computer to bus interface uses its on board clock to set the time stamps Kvaser MagiSync is an innovative way to synchronize several different Kvaser USB interfaces You do not need external cables you get instant synchronisation when you connect the MagiSync enabled Kvaser USB device Figure 3 An example setup where all devices are synchronized via...

Страница 9: ...hronized achieving a high precision virtual clock accurate to the microsecond 3 4 CAN connection The Kvaser U100S X3 has one CAN channel The CAN connector for the Kvaser U100S X3 is the 16 pin OBDII Type B plug which has the pinning described in Table 2 Figure 5 OBDII Type B CAN connector OBDII pin number Function 4 GND 6 CAN_H 14 CAN_L Table 2 OBDII pin configuration showing only connected pins K...

Страница 10: ...y or testing use the exact value of the termination resistors is not always critical Sometimes a single terminator is sufficient For production proper termination is essential If you see error frames on the bus you should check the termination To save yourself a lot of trouble always terminate the CAN bus properly 3 6 Power supply The Kvaser U100S X3 is powered through the USB connector Make sure ...

Страница 11: ...tus area towards the CAN end of the bar This is shown in Figure 7 Figure 7 The TX and RX LED bars on the Kvaser U100S X3 include status areas Different colors are used for different types of information and different blink patterns define the current state see Table 3 and Table 4 on Page 12 Color Information type Yellow Traffic Green Status Red Error White Alert Blue System Table 3 Different types...

Страница 12: ...ower is on On White Waiting for USB configuration Fast Blink Blue CAN channel is bus on On Green CAN channel traffic On Yellow Dynamic Yellow Error frame Dynamic Red CAN channel is error passive Fast Blink Red CAN overrun On Red Firmware update Slow Blink Blue Locate hardware Slow Blink White Slow Blink White Table 5 LED inidications in interface mode The Kvaser U100S X3 has one TX LED Bar and one...

Страница 13: ...ing data corresponding to 50 bus load in each direction for a total of 100 bus load The image on the right shows the unit transmitting data corresponding to 100 bus load Figure 9 The yellow lit area of the LED bars is proportional to the bus load Both images indicate a bus load of 100 3 9 The t programming language The Kvaser t programming language is event oriented and modelled after C It can be ...

Страница 14: ...to CAN bus events for example to speed up file transfer protocols or to simulate missing hardware For more information see the Kvaser t Programming Language guide that can be downloaded at www kvaser com download 3 10 Restrictions in t functionality The Kvaser U100S X3 is a dedicated CAN interface and as such does not contain real time clock RTC logger or SD card functionality neither does the Kva...

Страница 15: ...og kvIoPinGetOutputAnalog Predefined File I O Functions fileOpen fileClose fileGets fileReadBlock filePuts fileWriteBlock fileSeek fileDelete Predefined XML Functions xmlOpen xmlClose xmlGet Predefined t Program Related Functions scriptLoad Predefined Logger Related Functions filterDropMessage loggerStatus loggerStart loggerStop Other Predefined Functions timeGetDate Table 6 Functionality in the t...

Страница 16: ... showing the Firmware Update Instructions read and follow those carefully To check the current firmware version open Kvaser Device Guide which can be found in the Control Panel Select Kvaser U100S X3 in the tree view to the left and click on the channel The firmware revision information now appears in the right half of the window The absolute minimum firmware and driver versions needed in order to...

Страница 17: ...esolution 1 µs Max message rate 20 000 msg s per channel Error Frame Detection Yes Error Frame Generation Yes Silent mode Yes Kvaser MagiSync Yes Kvaser t programming Yes Kvaser CANtegrity No Host interface USB 2 0 standard USB type A connector Host OS Windows 7 or later Linux Power consumption Typical 250 mA Dimensions 38 x 128 x 26 mm for body Cable length USB 1 0 m CAN 0 3 m Weight 185 g includ...

Страница 18: ...nel to verify that the computer can communicate with the Kvaser U100S X3 If the firmware version shown is all zeros there are communication problems If the LED Bar or the status indication is not flashing or does not light up at all check the power supply Kvaser AB Mölndal Sweden www kvaser com ...

Страница 19: ...TIONS AND OPERATIONS WHICH MAY RESULT IN SERIOUS PHYSICAL HARM OR DEATH OR CAUSE DAMAGE TO EQUIPMENT DEVICES OR THE SURROUNDING ENVIRONMENT WITH THIS DEVICE YOU MAY POTENTIALLY CAUSE A CHANGE IN THE OPERATION OF THE SYSTEM MODULE DEVICE CIRCUIT OR OUTPUT TURN ON OR ACTIVATE A MODULE DEVICE CIRCUIT OUTPUT OR FUNCTION TURN OFF OR DEACTIVATE A MODULE DEVICE CIRCUIT OUTPUT OR FUNCTION INHIBIT TURN OFF...

Страница 20: ...n When this product reaches its end of life please dispose of it according to your local environmental laws and guidelines For information about Kvaser s recycling programs visit https www kvaser com en kvaser recycling policy html Kvaser AB Mölndal Sweden www kvaser com ...

Страница 21: ...paratus allowing traceability Product Kvaser U100S X3 Type 73 30130 01274 5 The object of the declaration described above is in conformity with the relevant Union harmonisation legislation Electromagnetic Compatibility EMC Directive 2014 30 EU Art 6 RoHS recast Directive 2011 65 EU Art 4 1 The following harmonised standards and technical specifications have been applied title date of standard spec...

Страница 22: ... 15 15 107 15 109 This device complies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation RESPONSIBLE PARTY IN USA NAME Kvaser Inc 23881 Via Fabricante Suite 503 Mission Viejo CA 92691 Internet contact sup...

Страница 23: ...be logo and Reader are either registered trademarks or trademarks of Adobe Systems Incorporated in the United States and or other countries MagiSync is a trademark of Kvaser AB DeviceNet is a trademark of Open DeviceNet Vendor Association Inc NMEA 2000 is the registered trademark of the National Marine Electronics Association Inc For information about Kvaser related CAN patents see www kvaser com ...

Страница 24: ...ment UG_98242_U100S X3 Revision Date Changes 1 0 2021 09 07 Initial version 1 1 2022 01 24 Added connector types to Technical Data section updated EU Declaration of Conformity 1 2 2022 04 01 Minor textual changes updated EU Declaration of Conformity Kvaser AB Mölndal Sweden www kvaser com ...

Отзывы: