manualshive.com logo in svg
background image

Manual

V1.0

2017.5

Содержание POWER-Z

Страница 1: ...Manual V1 0 2017 5 ...

Страница 2: ...USBA Micro USB TYPE C Long term Stability 50ppm 1000Hrs Dimension Length X Width X High 62X24X12 Weight 20g Power Supply Type HID port 5V other port self pickup electricity 3 7 24V Maximum input voltage except HID port 24V Working current 4 15mA Standby 3mA 5V QC2 0 QC3 0 Test Sniffing Support Power Delivery Test sniffing Support Pro version support PD2 0 protocol packet capture Typical interface ...

Страница 3: ... data management calibrate firmware update no driver needed plug and play Pro version can test PD2 0 protocol monitor the data on cc wires and decode display For example can capture the 10 packets of Mac s handshake decode and display each packet in characters suitable for development QC Protocol Test Sniff the USB interface of power adapter whether support QC2 0 3 0 or not PD Protocol Test Intern...

Страница 4: ...creen3 4 Run rules Menu button Switch next menu option Left Right button Open Close Change current threshold Auto Run Open this feature will automatic measure when load current exceed threshold preset such as 0 1A measurement don t create a new channel will stay the channel which Gauge choosed Auto Stop This parameter must small than value of Auto Run will stop measurement when load current less t...

Страница 5: ...ght button Switch to other main screen Curve speed Total 4 levels maximum 100SPS sample speed Curve type Can only display voltage or current decrease display speed Main screen4 Micro oscilloscope D D Curve Menu button Test QC2 0 3 0 protocol Left Right button Switch to other screen HVDCP Charge protocol information Sniff mode Current support QC2 0 Q3 0 will support more protocols in future 9 056V ...

Страница 6: ...een Website www chargerlab com My blog website can obtain more help information Copyright C 2017 LYSstudio Vision 1 0 www chargerlab com System setting1 Screen parameters Menu button Switch to next screen Left Right button Change screen brightness level Open screen saver mode Standby time Brightness Screen brightness step 5 range from 0 to 100 Saver Screen saver mode Sleep Standby time for example...

Страница 7: ...inimum values in the window Vp p Ip p Curve will scroll from right to left according to sample time The figure below displays noise of a standard 2 50000A high fidelity current source the noise actually is the interior noise of instrument in 100SPS high speed acquisition Could get better performance if set sample speed to 10SPS ...

Страница 8: ...roduce Offline data fetch and generate curve Cumulative display curve The time axis of curve remain 0 the curve will continuous compress Application case The figure below displays charge curve of a power bank ...

Отзывы: