manualshive.com logo in svg
background image

10.000

0

V

2.0000

0

A

20.000

0

W

0.0000 

mAh

0.0000 

mWh

00:00:000

LOAD

VBUS

CH1 H

Main screen1:Big font  Histogram 
Measurement information

Menu button

Click enter 

Gauge measurement 

screen, 

press to start or stop continue current storage 
channel measurement

Left|Right button

Switch to other main screen

00:00:000

Time of measurement
,Accumulate the voltage and current data 
every 100mS

CH1

Identify the internal record channel , total 5 
channels, each channel record the capacity , 
power , measurement time, offline curve,CH1 
is the first channel

H

Sample speed High(H) Middle(M)Low(L) for 
voltage sampling, high speed increase 
response speed will increase the power 
consumption, low speed can guarantee better 
accuracy and resolution.

VBUS、LOAD

VBUS stand for voltage of USB interface, 
LOAD stand for current of load

Menu screen1:Gauge measurement

Menu button

①Switch next menu option ②Quit

Left|Right button

①Manage storage channel ②Start,Stop ③
delete information

Menu screen3、4:

Run rules

Menu button

Switch next menu option

Left|Right button

①Open/Close ②Change current threshold

Auto Run

Open this feature will automatic measure 
when load current exceed threshold preset
such as 0.1A, measurement don’t create a 
new channel, will stay the channel which 
Gauge choosed

Auto Stop

This parameter must small than value of Auto
Run , will stop measurement when load 
current less than threshold preset such as 
0.05A.

End time

Auto stop time, this parameter restrict the 
maximum record time, maximum 10 hours, 
suitable for precisely control measurement 
time.

Sample per 
second

The number of data sampled per second, 
actually this is the number of filtering, the 
greater the value of the refresh rate faster.

Gauge

Menu screen2:

Record

Curve

Menu button

①Switch next menu option ②Quit modify 
area

Left|Right button

①Change record interval

Save space

Save intervals, min 3.6s,max 72s

Max record

Maximum record time, when record reach 
Save space X 2560 time will discard the 
subsequent data 

Record

Save space    10.8S

Max record 7.68H

Run rules

Auto Run                ON

Auto Stop              ON

0.100A

<run           0.050A

Run rules

End time                ON

1SPS

00:10

Sample per 
second

Message

Содержание POWER-Z

Страница 1: ...Manual V1 0 2017 5 ...

Страница 2: ...USBA Micro USB TYPE C Long term Stability 50ppm 1000Hrs Dimension Length X Width X High 62X24X12 Weight 20g Power Supply Type HID port 5V other port self pickup electricity 3 7 24V Maximum input voltage except HID port 24V Working current 4 15mA Standby 3mA 5V QC2 0 QC3 0 Test Sniffing Support Power Delivery Test sniffing Support Pro version support PD2 0 protocol packet capture Typical interface ...

Страница 3: ... data management calibrate firmware update no driver needed plug and play Pro version can test PD2 0 protocol monitor the data on cc wires and decode display For example can capture the 10 packets of Mac s handshake decode and display each packet in characters suitable for development QC Protocol Test Sniff the USB interface of power adapter whether support QC2 0 3 0 or not PD Protocol Test Intern...

Страница 4: ...creen3 4 Run rules Menu button Switch next menu option Left Right button Open Close Change current threshold Auto Run Open this feature will automatic measure when load current exceed threshold preset such as 0 1A measurement don t create a new channel will stay the channel which Gauge choosed Auto Stop This parameter must small than value of Auto Run will stop measurement when load current less t...

Страница 5: ...ght button Switch to other main screen Curve speed Total 4 levels maximum 100SPS sample speed Curve type Can only display voltage or current decrease display speed Main screen4 Micro oscilloscope D D Curve Menu button Test QC2 0 3 0 protocol Left Right button Switch to other screen HVDCP Charge protocol information Sniff mode Current support QC2 0 Q3 0 will support more protocols in future 9 056V ...

Страница 6: ...een Website www chargerlab com My blog website can obtain more help information Copyright C 2017 LYSstudio Vision 1 0 www chargerlab com System setting1 Screen parameters Menu button Switch to next screen Left Right button Change screen brightness level Open screen saver mode Standby time Brightness Screen brightness step 5 range from 0 to 100 Saver Screen saver mode Sleep Standby time for example...

Страница 7: ...inimum values in the window Vp p Ip p Curve will scroll from right to left according to sample time The figure below displays noise of a standard 2 50000A high fidelity current source the noise actually is the interior noise of instrument in 100SPS high speed acquisition Could get better performance if set sample speed to 10SPS ...

Страница 8: ...roduce Offline data fetch and generate curve Cumulative display curve The time axis of curve remain 0 the curve will continuous compress Application case The figure below displays charge curve of a power bank ...