manualshive.com logo in svg
background image

Function Features

High 
accuracy 
measuremen
t

Internal typical 0.02% accuracy measurement error and typical 
10ppm temperature drift ADC chip. The performance is better 
than MCP3421.In order to ensure the accuracy of the current 
sampling,  use a high quality typical temperature drift of 20ppm 
3W power rate sampling resistance. Up to 0.01% reading error.

Fast 
measuremen
t

While guaranteed accuracy, fast speed sampling, each 10mS 
gather the voltage and current data, 10 times faster than the other 
manufacturers, high-speed sampling to test the power supply’s 
output ripple, response speed, noise and other data.

Ripple Test

A function similar to Oscilloscopes, actually different to 
Oscilloscopes in measurement speed, can meet the usually test 
ripples frequency lower than 50Hz

Off-line 
curve

Internal mass storage memory, total 5 record groups, record 
maximum 50 hours each group. Can test the charge curve of 
electrical equipment, the save interval can be manual set.

Upper 
System APP

Powerful PC communication software, features such as: online 
data/offline data management , calibrate , firmware update, no 
driver needed, plug and play. Pro version can test PD2.0 protocol, 
monitor the data on cc wires and decode display. For example, 
can capture the 10 packets of Mac’s handshake, decode and 
display each packet in characters, suitable for development.

QC Protocol
Test

Sniff the USB interface of power adapter whether support QC2.0、
3.0 or not

PD Protocol
Test

Internal PD communication chip, Pro version can capture data 
through PC communication software, the Standard version also 
can monitor and sniff the power bank or power adapter’s USB 
interface whether support PD2.0 protocol or not

Plentiful
interfaces

Total 6 USB interfaces, one is HID communication and 
independent power supply, two Type-C USB interfaces consist a 
pair for Type-C test and PD communication, two Micro USB 
interfaces can test old standard data cables, two Type-A interface 
is common use test interfaces.

Functional 
Technical 
Specifications

Range

Resolution

Basic errors

VBUS Voltage

0-24V

0.1mV

±0.05%+5d (L)

LOAD Current

0-5A

0.1mA

±0.05%+5d (L)

Capacity/Power 0-199999Ah/Wh

0.0001mAh/mWh

±0.2%

Accumulate 1 time every 100ms, write to memory every 3.6s

L 表示采集速度最低时,在主界面观察到的数据 “L” means the data 
observed at the main interface when sampling low speed

Содержание POWER-Z

Страница 1: ...Manual V1 0 2017 5 ...

Страница 2: ...USBA Micro USB TYPE C Long term Stability 50ppm 1000Hrs Dimension Length X Width X High 62X24X12 Weight 20g Power Supply Type HID port 5V other port self pickup electricity 3 7 24V Maximum input voltage except HID port 24V Working current 4 15mA Standby 3mA 5V QC2 0 QC3 0 Test Sniffing Support Power Delivery Test sniffing Support Pro version support PD2 0 protocol packet capture Typical interface ...

Страница 3: ... data management calibrate firmware update no driver needed plug and play Pro version can test PD2 0 protocol monitor the data on cc wires and decode display For example can capture the 10 packets of Mac s handshake decode and display each packet in characters suitable for development QC Protocol Test Sniff the USB interface of power adapter whether support QC2 0 3 0 or not PD Protocol Test Intern...

Страница 4: ...creen3 4 Run rules Menu button Switch next menu option Left Right button Open Close Change current threshold Auto Run Open this feature will automatic measure when load current exceed threshold preset such as 0 1A measurement don t create a new channel will stay the channel which Gauge choosed Auto Stop This parameter must small than value of Auto Run will stop measurement when load current less t...

Страница 5: ...ght button Switch to other main screen Curve speed Total 4 levels maximum 100SPS sample speed Curve type Can only display voltage or current decrease display speed Main screen4 Micro oscilloscope D D Curve Menu button Test QC2 0 3 0 protocol Left Right button Switch to other screen HVDCP Charge protocol information Sniff mode Current support QC2 0 Q3 0 will support more protocols in future 9 056V ...

Страница 6: ...een Website www chargerlab com My blog website can obtain more help information Copyright C 2017 LYSstudio Vision 1 0 www chargerlab com System setting1 Screen parameters Menu button Switch to next screen Left Right button Change screen brightness level Open screen saver mode Standby time Brightness Screen brightness step 5 range from 0 to 100 Saver Screen saver mode Sleep Standby time for example...

Страница 7: ...inimum values in the window Vp p Ip p Curve will scroll from right to left according to sample time The figure below displays noise of a standard 2 50000A high fidelity current source the noise actually is the interior noise of instrument in 100SPS high speed acquisition Could get better performance if set sample speed to 10SPS ...