1 - SAFETY NOTICE
2 - ELECTRICAL CONNECTIONS
- This Instructions Manual (Instructions) contains important information regarding safety
- Read the entire document before you install any of the equipment
- Installation must be carried out by qualified installers
- Installation must be in accordance with all state and federal laws and regulations relating to Electrical Safety
in your area
- Make sure that all cabling and wiring are in accordance with Wiring Rules AS 3000:2007
- Do not modify the equipment unless directed to by the Instructions. Modifications may cause irreversible
damage to the equipment and result in malfunction. King-Gates and LiteStart disclaim any liability for damage
resulting from modified equipment.
- Ensure that no damage will be caused by automating the gate. Pay particular attention to any damage that
may be caused by impact, crushing, shearing, dragging, etc. as well as other general dangers.
Before installing any of the equipment ensures that the gate can move freely through its motion and that nothing
is blocking or interfering with its path of travel.
- During installation and use, ensure that solid objects or liquids cannot enter the control box.
Before connecting the control box to the mains power
1 - Verify that all wirings done as described in section 2 above
2 - Ensure that the gate can move freely through its motion and that nothing is blocking or interfering with its
path of travel
3 - Ensure that no damage will be caused by automating the gate
4 - Motor’s terminals MUST be plugged in before powering the box
1 - Safety notice
2 - Electrical connection
3 - DIPSWITCHES Setting
4 - Linear adjustment Potentiometers
5 - Remote Control Programming - Main, Vehicle access
6 - Remote Control Programming - Pedestrian access
7 - Remote Control - Deleting all remote codes from control unit memory
8 - POWER, SPEED, OBSTACLE Adjustments
9 - Automatic Gate Travel learning
ADVANCED PROGRAMMING
10 - SLOWDOWN points - Changing the factory default setting
11 - PEDESTRIAN opening adjustment
12 - PEDESTRIAN opening – cancelling gap adjustment
13 - PEDESTRIAN access deleting all remote control codes
ADVANCE FEATURES
14 - Safety devices – detailed descriptions
15 - Accessories, Optional
16 - Status LED’s
17 - Inside the control unit (ADVANCED ONLY)
18 - TROUBLE SHOOTING
Page
2
3
4
4
5
5
5
5
6
6
6
6
7
7
8
8
9
10
Section
2
3
MOTOR WIRES
OPEN INWARD
DipSwitches
Section 3
Programming
button
Potentiometers
(section 4)
White
Brown
White
Brown
(Reverse wires for
outward opening)
NOTE:
- All connections to the board must be voltage free contacts
(“dry Contacts”)
- For motors without limit switches, terminals 3,4,5,6 and 7
are not used and must not be bridged (linked)
- The unit comes with safety devices’ inputs (terminals 16
and 17) and the STOP input (terminal 4) all bridged (linked)
to the COM (T13, 18)
- When connecting safety or STOP devices, remove the links
from these terminals.
- For single wing gates, use only MOT1. Single / double
motor set up done automatically with the gate travel learning
Motor wires
open inward:
White 24, 26
Brown 25,27
Cable length and cross section
- If the distance between the control unit and the grounding system is more than 30m, then it is necessary to install an
electric discharger near the control unit
- Cables used for low-voltage features must be at least 0.25 mm2 for distance up to 30meters
- Use shielded (screened) cables that are at least 0.5mm2 for distance 30 -100meter
- Do not connect cables in underground boxes or inside conduits
POWER SUPPLY (N)
24O VAC(L)
+
19 18
18
16
19 18
RX
TX
NC
NO
C
-
MOTOR 1
MOTOR 2
21. 22.23.
TRANSFORMER
1. ANTENNA in
2. ANTENNA shield
3. Opening limit switch motor 1
4. Closing limit switch motor 1
5. Terminals 3,4,6,7 common
6. Opening limit switch motor 2
7. Closing limit switch motor 2
8.
ELECTRIC LOCK 12V
9.
24Vdc power
10.
HAZARD LIGHT
12 V 100mA
11. OV
12. PUSH BUTTON
START
13. COMMON for Terminals 12, 14, 15
14.
STOP
15. Pedestrian opening contact
PED
16. Safety 1
PHO1
17. Safety 2
PHO2
18. COM. for Terminals 9, 19 and 20 (OV)
19.
12Vdc power
20.
INDICATION LIGHT
(12Vdc max 3W)
CLOSING PHOTOCELL
CONNECTION
PHOTO 1
PHOTOCELL CONNECTION - VIKY SERIES
PHOTO 2
OPENING PHOTOCELL
CONNECTION
+ -
+
19 18 17
19 18
RX
TX
NC
NO
C
-
18
+ -
FUSE 3.15A
ANT
GND
FOP1
FCC1
COM
FOP2
FCC2
LOCK
24Vdc
HAZ
COM
START
COM
STOP
PED
PHO1
PHO2
COM
12Vdc
TEST
24Vac
0V
12Vac
MOT1
MOT2
27 26 25 24 23 22 21
BLACK
BLUE
ORANGE
MEMORY
TERMINAL
MEMORY
CARD
ORIENTATION
12V 2A FUSE
RECEIVER
ORIENTATION
CONTROL UNIT
2A
LOCK